Sensor systems for bioprocess monitoring
The DOI matches its Crossref record; 230 of the 230 references it cites were found in a registry or an index.
Abstract
The ability to measure all process variables is of great importance in the field of bioprocess monitoring and control, and continuous, real‐time measurements are highly desired. The more complete and real‐time the measurements are, the more stable, reproducible, and efficient the process can be, leading to reproducibly high‐quality products. This additional information allows the operator to better document the entire process. The process analytical technologies initiative of the US Food and Drug Administration is strongly related to the analysis and control of biopharmaceutical processes. The aim of the initiative is to create processes, generating products of ensured quality by measuring quality‐related process variables. The quality of the product is enhanced by a deep understanding of the process, which is enabled by an effective and suitable sensor system. The aim of this review is to provide an overview of current and emerging sensors for bioprocess monitoring. Sensors directly interfaced to bioreactors for measuring important variables from the gas phase, such as oxygen and carbon dioxide concentration, are discussed, as well as sensors for the monitoring of the biomass concentration and morphology and of the changing medium composition. Furthermore, sensor systems are discussed. These involve sensors (especially biosensors) that are not implemented directly inside the bioreactor but rather are used in conjunction with sample‐taking systems such as flow injection analysis. A major focus is given to spectroscopic sensors, which are noninvasive and offer interesting options for a simultaneous analysis of various compounds. Since data handling is extremely important for this kind of sensor, chemometrics are also included. Soft sensors are discussed as technology that allows a user to incorporate more process data as it become available. Finally, the current state of disposable sensor technology is presented. These sensors are needed for the growing area of disposable and continuous biomanufacturing.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498 · cited 2×
“Another approach uses the enzymes glucose/fructose oxidoreductase and gluconolactonase, immobilized upon a pH electrode, which determines the production of hydrogen ions resulting from the enzymatic turnover in presence of glucose [51, 58, 59].”
BackgroundMethodReview of the most common pre-processing techniques for near-infrared spectra
Rinnan, Å., Berg, F. V. D., & Engelsen, S. B. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.07.007 · Cited by 3,057 · cited 1×
“Filtering [190], centering, normalization, standardization, deviation [191], wavelength selection [192, 193], weighing, and scaling are common preprocessing methods for multivariate data [6, 194].”
MethodElectrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329 · cited 1×
“Other reviews focus on specific biosensor classes, including calorimetric [52, 55–57], optical [39, 41], and electrochemical biosensors [38, 43, 44].”
BackgroundData-driven Soft Sensors in the process industry
Kadlec, P., Gabrys, B., & Strandt, S. (2009) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2008.12.012 · Cited by 1,845 · cited 2×
“using mass preservation principles or energy balances) [223, 228].”
BackgroundMethodElectrochemical biosensors: recommended definitions and classification
Thévenot, D. R., Toth, K., Durst, R. A., & Wilson, G. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00115-4 · Cited by 1,727
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Bioreactor scale-up and oxygen transfer rate in microbial processes: An overview
Garcia-Ochoa, F., & Gomez, E. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.10.006 · Cited by 1,504
Song, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
A review of near infrared spectroscopy and chemometrics in pharmaceutical technologies
Roggo, Y., Chalus, P., Maurer, L., Lema-Martinez, C., Edmond, A., & Jent, N. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.03.023 · Cited by 1,131
Ṙuz̆ic̆ka, J., & Hansen, E. H. (1975) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)84761-9 · Cited by 1,025
Research works printed but not linked: 12
- R. W. Kessler 2006 Wiley‐VCH Weinheim
- Shuk P., 2010, Process zirconia oxygen analyzer‐state of art. tm‐Technisches Messen Plattform für Methoden, Systeme und Anwendungen der Messtechnik., 77, 19
- Pohlscheidt M., 2009, Bioprocess and Fermentation Monitoring, in Encyclopedia of Industrial Biotechnology
- Ruzicka J., 1988, Chemical Analysis
- Ulber R., 2000, Academic Press, Enyclopedia of Microbiology, 567
- Glindkamp A., 2009, Sensors in disposable bioreactors status and trends, Adv. Biochem. Eng. Biotechnol., 115, 145
- Henriques J. G., 2010, Optical Sensor Systems in Biotechnology, 29
- Card C., 2008, Near‐infrared spectroscopy for rapid, simultaneous monitoring, BioProcess Int., 6, 58
- Moretto J., 2011, Process Raman spectroscopy for in‐line CHO cell culture monitoring, Am. Pharmaceut. Rev., 14, 18
- Lottspeich F., 2006, Bioanalytik
- Logan D. W., 2011, BMC Proc, P57
- Shaw A. D., 1999, Advances in Biochemical Engineering and Biotechnology, 83
Cited by
Paper Electrode-Based Flexible Pressure Sensor for Point-of-Care Immunoassay with Digital Multimeter
Yu, Z., Tang, Y., Cai, G., Ren, R., & Tang, D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04635 · Cited by 341
Digital Twins in Pharmaceutical and Biopharmaceutical Manufacturing: A Literature Review
Chen, Y., Yang, O., Sampat, C., Bhalode, P., Ramachandran, R., & Ierapetritou, M. (2020) · Processes · doi:10.3390/pr8091088 · Cited by 278
“In the gas phase, the commonly used sensing system consists of semiconducting, electrochemical, and paramagnetic sensors, which can be applied to oxygen and carbon dioxide measurements [185,186].”
BackgroundMethodClaßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
“It includes a gas (aeration), a liquid (growth medium), and a solid phase (cells) [5].”
BackgroundInfluentialSelf-citationProcess Analytical Technologies – Advances in bioprocess integration and future perspectives
Gerzon, G., Sheng, Y., & Kirkitadze, M. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2021.114379 · Cited by 176
Blueprints for Biosensors: Design, Limitations, and Applications
Carpenter, A. C., Paulsen, I. T., & Williams, T. C. (2018) · Genes · doi:10.3390/genes9080375 · Cited by 183
“This involves the sampling of large scale biological processes such as beer/wine fermentations, garbage degradation, or bio-remediation [13,14].”
BackgroundQuality by control: Towards model predictive control of mammalian cell culture bioprocesses
Sommeregger, W., Sissolak, B., Kandra, K., von Stosch, M., Mayer, M., & Striedner, G. (2017) · Biotechnology Journal · doi:10.1002/biot.201600546 · Cited by 159
Gargalo, C. L., Udugama, I., Pontius, K., Lopez, P. C., Nielsen, R. F., Hasanzadeh, A., Mansouri, S. S., Bayer, C., Junicke, H., & Gernaey, K. V. (2020) · Journal of Industrial Microbiology and Biotechnology · doi:10.1007/s10295-020-02308-1 · Cited by 133
“AI Artificial intelligence BCA Background corrected absorption NAD(P)H Nicotinamide adenine dinucleotide phosphate FDA Food and drug administration FTIR Fourier-transform infrared spectroscopy GC–MS Gas chromatography–Mass spectrometry GFP Green fluorescent protein GMP Good manufacturing practice HMI Human machine int…”
BackgroundBioprocess Control: Current Progress and Future Perspectives
Rathore, A. S., Mishra, S., Nikita, S., & Priyanka, P. (2021) · Life · doi:10.3390/life11060557 · Cited by 141
Between the Poles of Data‐Driven and Mechanistic Modeling for Process Operation
Solle, D., Hitzmann, B., Herwig, C., Pereira Remelhe, M., Ulonska, S., Wuerth, L., Prata, A., & Steckenreiter, T. (2017) · Chemie Ingenieur Technik · doi:10.1002/cite.201600175 · Cited by 134
Self-citationModern Sensor Tools and Techniques for Monitoring, Controlling, and Improving Cell Culture Processes
Reyes, S. J., Durocher, Y., Pham, P. L., & Henry, O. (2022) · Processes · doi:10.3390/pr10020189 · Cited by 130
Process Analytical Technologies and Data Analytics for the Manufacture of Monoclonal Antibodies
Maruthamuthu, M. K., Rudge, S. R., Ardekani, A. M., Ladisch, M. R., & Verma, M. S. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2020.07.004 · Cited by 97
“UV-vis spectroscopy 240–340 nm Cell density, aromatic amino acids – [48]”
InfluentialCultivating Multidisciplinarity: Manufacturing and Sensing Challenges in Cultured Meat Production
Djisalov, M., Knežić, T., Podunavac, I., Živojević, K., Radonić, V., Knežević, N. Ž., Bobrinetskiy, I. I., & Gadjanski, I. (2021) · Biology · doi:10.3390/biology10030204 · Cited by 111
Challenges in the Development of Soft Sensors for Bioprocesses: A Critical Review
Brunner, V., Siegl, M., Geier, D., & Becker, T. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.722202 · Cited by 100
Smiatek, J., Jung, A., & Bluhmki, E. (2020) · Trends in biotechnology · doi:10.1016/j.tibtech.2020.05.008 · Cited by 110
Bioengineering Outlook on Cultivated Meat Production
Pajčin, I., Knežić, T., Azoulay, I. S., Vlajkov, V., Djisalov, M., Janjušević, L., Grahovac, J. A., & Gadjanski, I. (2022) · Micromachines · doi:10.3390/mi13030402 · Cited by 98
Challenges and Opportunities of Implementing Data Fusion in Process Analytical Technology—A Review
Casian, T., Nagy, B., Kovács, B., Galata, D. L., Hirsch, E., & Farkas, A. (2022) · Molecules · doi:10.3390/molecules27154846 · Cited by 95
“Real-time measurements of basic physicochemical parameters (such as temperature, pH, conductivity, dissolved O2 and CO2, impeller speed, pressure, flow rate, weight, and moisture content) resulting in one-dimensional data are conventionally carried out during biopharmaceutical production [56,57].”
BackgroundTowards the Development of Digital Twins for the Bio-manufacturing Industry
Gargalo, C. L., Heras, S. C. D. L., Jones, M., Udugama, I. A., Mansouri, S. S., Krühne, U., & Gernaey, K. V. (2020) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2020_142 · Cited by 102
Advances in process monitoring tools for cell culture bioprocesses
Zhao, L., Fu, H., Zhou, W., & Hu, W. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500006 · Cited by 81
The Epic of In Vitro Meat Production—A Fiction into Reality
Balasubramanian, B., Liu, W., Pushparaj, K., & Park, S. (2021) · Foods · doi:10.3390/foods10061395 · Cited by 80
Automation and artificial intelligence in filamentous fungi-based bioprocesses: A review
Wainaina, S., & Taherzadeh, M. J. (2022) · Bioresource Technology · doi:10.1016/j.biortech.2022.128421 · Cited by 86
On-Line Monitoring of Biological Parameters in Microalgal Bioprocesses Using Optical Methods
Havlik, I., Beutel, S., Scheper, T., & Reardon, K. F. (2022) · Energies · doi:10.3390/en15030875 · Cited by 73
“As in the previous case, on-line turbidity data calibrated with DWC with a 5 s sampling rate and off-line glucose data in 1 h intervals were used as process inputs for the UKF estimating the lipid concentrations, and all three variables were fed into the MPC to calculate process control inputs…”
Self-citationSensors for disposable bioreactors
Busse, C., Biechele, P., de Vries, I., Reardon, K. F., Solle, D., & Scheper, T. H. (2017) · Engineering in Life Sciences · doi:10.1002/elsc.201700049 · Cited by 69
Self-citationSamaras, J. J., Micheletti, M., & Ding, W. (2022) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-092220-030223 · Cited by 71
Young, A. T., Rivera, K. R., Erb, P. D., & Daniele, M. A.-A. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01549 · Cited by 65
Sokolov, M., Morbidelli, M., Butté, A., Souquet, J., & Broly, H. (2018) · Biotechnology Journal · doi:10.1002/biot.201700461 · Cited by 56
Digital Twins in Biomanufacturing
Zobel‐Roos, S., Schmidt, A., Uhlenbrock, L., Ditz, R., Köster, D., & Strube, J. (2020) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2020_146 · Cited by 72
Kornecki, M., & Strube, J. (2018) · Bioengineering · doi:10.3390/bioengineering5010025 · Cited by 61
Mainka, T., Weirathmüller, D., Herwig, C., & Pflügl, S. (2021) · Journal of Industrial Microbiology & Biotechnology · doi:10.1093/jimb/kuab015 · Cited by 59
“Process variables which are commonly used for biomass soft sensors are offgas values (CO2, O2), base consumption or dissolved oxygen (pO2) (Biechele et al., 2015; Kager et al., 2018; Kiviharju et al., 2008; Sundström & Enfors, 2008).”
BackgroundMethodInfluentialToward Biotherapeutic Product Real‐Time Quality Monitoring
Guerra, A., von Stosch, M., & Glassey, J. (2019) · Critical Reviews in Biotechnology · doi:10.1080/07388551.2018.1524362 · Cited by 58
“The necessity for real-time CQA measurements increased due to real-time parametric release monitoring, as promoted within the PAT [34].”
BackgroundMethodInfluentialMonitoring of eicosapentaenoic acid (EPA) production in the microalgae Nannochloropsis oceanica
Sá, M., Ferrer-Ledo, N., Wijffels, R., Crespo, J. G., Barbosa, M., & Galinha, C. F. (2020) · Algal Research · doi:10.1016/j.algal.2019.101766 · Cited by 58
Ultraviolet-visible spectroscopy for food quality analysis
Power, A., Chapman, J., Chandra, S., & Cozzolino, D. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814217-2.00006-8 · Cited by 71
The Use of UV-Vis Spectroscopy in Bioprocess and Fermentation Monitoring
Roberts, J., Power, A., Chapman, J., Chandra, S., & Cozzolino, D. (2018) · Fermentation · doi:10.3390/fermentation4010018 · Cited by 53
Optics miniaturization strategy for demanding Raman spectroscopy applications
Ilchenko, O. O., Pilgun, Y., Михайлович, К. А., Slobodianiuk, D. V., Göksel, Y., Dumont, E., Vaut, L., Mazzoni, C., Morelli, L., Boisen, S., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-47044-7 · Cited by 53
“These tools include probes for temperature, pH, dissolved gases and organic carbon, and spectroscopic probes, also including Raman probes 83,84 .”
Afedzi, A. E. K., Afrakomah, G. S., Gyan, K., Khan, J., Seidu, R., Baidoo, T., Sultan, I. N., Tareen, A. K., & Parakulsuksatid, P. (2025) · Sustainability · doi:10.3390/su17020499 · Cited by 53
Advances in bioreactor control for production of biotherapeutic products
Nikita, S., Mishra, S., Gupta, K., Runkana, V., Gomes, J., & Rathore, A. S. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28346 · Cited by 52
Software sensors in the monitoring of microalgae cultivations
Porras Reyes, L., Havlik, I., & Beutel, S. (2024) · Reviews in Environmental Science and Bio/Technology · doi:10.1007/s11157-023-09679-8 · Cited by 48
“Chemometrics, a concept initially introduced by Svante Wolf in 1971, is the method of extracting information from chemical systems by data-driven methods (Sarker and Nahar 2015; Biechele et al. 2015).”
InfluentialNanotechnology and E-Sensing for Food Chain Quality and Safety
Poeta, E., Liboà, A., Mistrali, S., Núñez-Carmona, E., & Sberveglieri, V. (2023) · Sensors · doi:10.3390/s23208429 · Cited by 49
“In-line sensors should be resistant to pressure, temperature between 35 and 55 °C, cleaning processes, and the response time [229].”
BackgroundPivotal role of electrospun nanofibers in microfluidic diagnostic systems – a review
Rezaei, Z., & Mahmoudifard, M. (2019) · Journal of Materials Chemistry B · doi:10.1039/c9tb00682f · Cited by 47
Perspectives of optical colourimetric sensors for anaerobic digestion
Lamb, J. J., Bernard, O., Sarker, S., Lien, K. M., & Hjelme, D. R. (2019) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2019.04.083 · Cited by 47
“For live (on-line) monitoring of a biogas plant to be useful, the response time of the sensors is an important characteristic [20].”
BackgroundMethodAddressing the Manufacturing Challenges of Cell-Based Therapies
Fuzeta, M. D. A., Branco, A. D. D. M., Fernandes‐Platzgummer, A., da Silva, C. L., & Cabral, J. M. S. (2019) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2019_118 · Cited by 54
Sensors and Techniques for On-Line Determination of Cell Viability in Bioprocess Monitoring
Rösner, L., Walter, F., Ude, C., John, G., & Beutel, S. (2022) · Bioengineering · doi:10.3390/bioengineering9120762 · Cited by 42
“In consequence, this MIR region is predominantly used for the identification of multiple compounds in the culture broth [13,77].”
BackgroundMethodInfluentialJoseph, J. A., Akkermans, S., & van Impe, J. F. M. (2022) · ACS Omega · doi:10.1021/acsomega.2c00055 · Cited by 35
Soft sensor for monitoring biomass subpopulations in mammalian cell culture processes
Kröll, P., Stelzer, I. V., & Herwig, C. (2017) · Biotechnology Letters · doi:10.1007/s10529-017-2408-0 · Cited by 34
Zimmerleiter, R., Kager, J., Nikzad‐Langerodi, R., Berezhinskiy, V., Westad, F., Herwig, C., & Brandstetter, M. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02227-w · Cited by 34
Claßen, J., Graf, A., Aupert, F., Solle, D., Hoehse, M., & Scheper, T. H. (2019) · Engineering in Life Sciences · doi:10.1002/elsc.201800146 · Cited by 32
“By these sensors, an efficient process control of several process variables is accessible simultaneously with no delay between sampling and analysis [6] .”
BackgroundSelf-citationKnežić, T., Janjušević, L., Djisalov, M., Yodmuang, S., & Gadjanski, I. (2022) · Biomolecules · doi:10.3390/biom12050699 · Cited by 31
“As this review focuses on the cell-related aspects of CA-procedures for obtaining CM/CF/CS products, we invite the reader to consult other excellent recent reviews and publications that cover other aspects relevant to CA, such as support structures for cell immobilization comprising microcarriers (MCs) [12,13] and 3D…”
BackgroundPauliukaitė, R., & Voitechovič, E. (2020) · Sensors · doi:10.3390/s20123551 · Cited by 30
“Recently, many other chemometric methods have been used for the extraction of the required information about a sample, according to the particular task at hand [8,12].”
MethodBrignoli, Y., Freeland, B. H., Cunningham, D., & Dabros, M. (2020) · Processes · doi:10.3390/pr8060679 · Cited by 28
“The second approach, invasive to the process, includes the application of an in-situ optical density probe [13–15], dielectric (capacitance) spectroscopy [16–18], or fluorescence spectroscopy [19,20] to monitor biomass.”
BackgroundMethodReal-time bioprocess monitoring using a mid-infrared fibre-optic sensor
Alimagham, F., Winterburn, J. B., Dolman, B. M., Domingues, P. M., Everest, F. L. C., Platkov, M., Basov, S., Izakson, G., Katzir, A., Elliott, S. R., et al. (2020) · Biochemical Engineering Journal · doi:10.1016/j.bej.2020.107889 · Cited by 28
Enhancing recombinant growth factor and serum protein production for cultivated meat manufacturing
Mainali, P., Chua, M. S.-W., Tan, D.-J., Loo, B. L.-W., & Ow, D. S. (2025) · Microbial Cell Factories · doi:10.1186/s12934-025-02670-8 · Cited by 29
Pinto, I. F., Soares, R. R. G., Mäkinen, M., Chotteau, V., & Russom, A. (2021) · ACS Sensors · doi:10.1021/acssensors.0c01884 · Cited by 29
Sensor technologies for quality control in engineered tissue manufacturing
McCorry, M. C., Reardon, K. F., Black, M. R., Williams, C., Babakhanova, G., Halpern, J. M., Sarkar, S., Swami, N. S., Mirica, K. A., Boermeester, S., et al. (2022) · Biofabrication · doi:10.1088/1758-5090/ac94a1 · Cited by 27
Self-citationOn-line monitoring of process parameters during fermentation
Gargalo, C. L., López, P. C., Hasanzadeh, A., Udugama, I. A., & Gernaey, K. V. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-91167-2.00003-4 · Cited by 35
Environmental Control in Flow Bioreactors
Giusti, S., Mazzei, D., Cacopardo, L., Mattei, G., Domenici, C., & Ahluwalia, A. D. (2017) · Processes · doi:10.3390/pr5020016 · Cited by 26
“The importance of chemical and physical measurements is reported in [6], where the authors also outlined the difference between on-line, in-line, and at-line measurements.”
BackgroundMöller, J., Bhat, K., Riecken, K., Pörtner, R., Zeng, A., & Jandt, U. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.27124 · Cited by 27
Drieschner, T., Ostertag, E., Boldrini, B., Lorenz, A., Brecht, M., & Rebner, K. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02322-y · Cited by 26
“It is applied for many years to determine multiple process parameters in the media of cell cultivations [6].”
BackgroundCurrent and future technologies for monitoring cultured meat: A review
Pawar, D., Presti, D. L., Silvestri, S., Schena, E., & Massaroni, C. (2023) · Food Research International · doi:10.1016/j.foodres.2023.113464 · Cited by 27
Lipase, Phospholipase, and Esterase Biosensors (Review)
Sandoval, G., & Herrera-López, E. J. (2018) · Methods in molecular biology · doi:10.1007/978-1-4939-8672-9_22 · Cited by 25
Alarcón, C., & Shene, C. (2021) · Computers in Industry · doi:10.1016/j.compind.2021.103431 · Cited by 25
Trends and new process analytical technologies in pharmaceutical manufacturing
Wu, S., Liu, Y., Fan, X., Shen, Y., & Qu, H. (2025) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2025.125957 · Cited by 27
DNA-Based Photoacoustic Nanosensor for Interferon Gamma Detection
Morales, J. M., Pawle, R. H., Akkılıç, N., Luo, Y., Xavierselvan, M., Albokhari, R., Calderon, I. A. C., Selfridge, S., Minns, R. A., Takiff, L., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00209 · Cited by 24
Monitoring and control of E. coli cell integrity
Kastenhofer, J., Rajamanickam, V., Libiseller-Egger, J., & Spadiut, O. (2021) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2021.01.009 · Cited by 26
Helgers, H., Hengelbrock, A., Schmidt, A., Rosengarten, J. F., Stitz, J., & Strube, J. (2022) · Processes · doi:10.3390/pr10020419 · Cited by 23
Musmann, C., Joeris, K., Markert, S., Solle, D., & Scheper, T. H. (2016) · Engineering in Life Sciences · doi:10.1002/elsc.201500122 · Cited by 23
Self-citationPerspectives of surface plasmon resonance sensors for optimized biogas methanation
Lamb, J. J., Olivier Bernard, A., Sarker, S., Lien, K. M., & Hjelme, D. R. (2019) · Engineering in Life Sciences · doi:10.1002/elsc.201900063 · Cited by 21
“For live, online detection of an AD plant to be valuable, the reaction time of the sensors is a critical feature [25].”
BackgroundMethodKäßer, L., Rotter, M., Coletta, L. A., Salzig, D., & Czermak, P. (2022) · Scientific Reports · doi:10.1038/s41598-022-04931-7 · Cited by 21
Real‐time optimization and control for polyhydroxybutyrate fed‐batch production at pilot plant scale
Ochoa, S., García, C. A., & Zapata, W. A. (2020) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.6500 · Cited by 21
Alternative proteins production: current scenario, bioreactor types, and scale-up strategies
Vandenberghe, L. P. D. S., de Mello, A. F. M., Machado, C. M. B., Biagini, G., de Mattos, P. B. G., Piazenski, I. N., Candelário, J. P. M., & Soccol, C. R. (2024) · Systems Microbiology and Biomanufacturing · doi:10.1007/s43393-024-00309-0 · Cited by 22
“Some sensors can also be disposable, and therefore be used in single-use bioreactors systems [98].”
Continuous noninvasive monitoring of cell growth in disposable bioreactors
Reinecke, T., Biechele, P., Sobociński, M., Suhr, H., Bakes, K., Solle, D., Jantunen, H. M., Scheper, T. H., & Zimmermann, S. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.05.111 · Cited by 20
Self-citationSá, M., Ramos, A., Monte, J., Brazinha, C., Galinha, C. F., & Crespo, J. G. (2019) · Journal of Applied Phycology · doi:10.1007/s10811-019-01999-z · Cited by 20
“Several spectroscopies have been studied for this purpose, namely fluorescence (Tartakovsky et al. 1996; Shaw et al. 1999; Schügerl 2001; Hantelmann et al. 2006; Glindkamp et al. 2009; Galinha et al. 2012; Ranzan et al. 2012; Biechele et al. 2015).”
BackgroundGrīgs, O., Bolmanis, E., & Galvanauskas, V. (2021) · Sensors · doi:10.3390/s21041268 · Cited by 21
Mishra, A., Aghaee, M., Tamer, I. M., & Budman, H. (2025) · Spectroscopy Journal · doi:10.3390/spectroscj3020012 · Cited by 19
“For biomass concentration measurements, UV/Vis sensors can achieve an accuracy of approximately ±3% to ±8% of full scale, especially when enhanced with chemometric analysis to reduce background interference [49].”
Automated outlier detection and estimation of missing data
Rhyu, J., Bozinovski, D. M., Dubs, A. B., Mohan, N., Bende, E. M. C., Maloney, A. J., Nieves, M. J., Sangerman, J., Lu, A. E., Hong, M. S., et al. (2023) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2023.108448 · Cited by 20
“TotalD and ViableD stand for total density and viable density, respectively. useful for process modeling or process estimation (Fujimori et al., 1990; Heinzle et al., 2007; Biechele et al., 2015).”
Advances and opportunities in process analytical technologies for viral vector manufacturing
Sripada, S. A., Hosseini, M., Ramesh, S., Wang, J., Ritola, K., Menegatti, S., & Daniele, M. A.-A. (2024) · Biotechnology Advances · doi:10.1016/j.biotechadv.2024.108391 · Cited by 19
Luminescence-Based Sensors for Bioprocess Applications
Urriza-Arsuaga, I., Ielasi, G., Bedoya, M., & Orellana, G. (2019) · Springer series on fluorescence · doi:10.1007/4243_2019_10 · Cited by 21
Escalante-Sánchez, A., Barrera-Cortés, J., Poggi-Varaldo, H. M., Ponce‐Noyola, T., & Baruch, I. S. (2018) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-018-1975-3 · Cited by 19
Song, E., Tao, Y., Shen, H., Yang, C. J., Tian, T., Liu, Y., & Zhu, Z. (2022) · The Analyst · doi:10.1039/d2an00370h · Cited by 18
Hengelbrock, A., Schmidt, A., Helgers, H., Vetter, F. L., & Strube, J. (2023) · Processes · doi:10.3390/pr11030745 · Cited by 18
Guardalini, L. G. O., Dias, V. A. T., Leme, J., Bernardino, T. C., Astray, R. M., da Silveira, S. R., Ho, P. L., Tonso, A., Jorge, S. A. C., & Núñez, E. G. F. (2023) · Biochemical Engineering Journal · doi:10.1016/j.bej.2023.109013 · Cited by 18
Lamb, J. J., Lien, K. M., & Hjelme, D. R. (2019) · MethodsX · doi:10.1016/j.mex.2019.11.002 · Cited by 16
“Principle component analysis (PCA) allows the reduction of high-dimensional data to fewer, linearly independent components [1,6].”
BackgroundMethodWell-Defined Conjugated Macromolecules Based on Oligo(Arylene Ethynylene)s in Sensing
Krywko-Cendrowska, A. N., Szweda, D., & Szweda, R. (2020) · Processes · doi:10.3390/pr8050539 · Cited by 17
“The monitoring of bioprocesses in an organism is performed by cascade communication between the network of biomolecules [1].”
BackgroundThe Kalman Filter for the Supervision of Cultivation Processes
Yousefi-Darani, A., Paquet-Durand, O., & Hitzmann, B. (2020) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/10_2020_145 · Cited by 15
Robust control of fed-batch high-cell density cultures: a simulation-based assessment
Ibáñez, F., Saa, P. A., Bárzaga-Martell, L., Duarte‐Mermoud, M. A., Fernández‐Fernández, M., Agosin, E. E., & Pérez‐Correa, J. R. (2021) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2021.107545 · Cited by 15
Process control strategies applied to microalgae-based biofuel production
Nwoba, E. G., Chuka-ogwude, D., Vadiveloo, A., & Ogbonna, J. C. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-90971-6.00031-0 · Cited by 19
Ning, X., Yasuda, T., Kitaguchi, T., & Ueda, H. (2021) · Sensors · doi:10.3390/s21154993 · Cited by 15
“However, most of these sensor technologies target environmental variables, such as temperature, dissolved oxygen/carbon dioxide, and metabolites [1].”
BackgroundFeedback control based on NADH fluorescence intensity for Saccharomyces cerevisiae cultivations
Assawajaruwan, S., Kuon, F., Funke, M., & Hitzmann, B. (2018) · Bioresources and Bioprocessing · doi:10.1186/s40643-018-0210-z · Cited by 14
“Two-dimensional (2D) fluorescence spectroscopy is an effective tool for online monitoring of cultivation processes (Biechele et al. 2015; Faassen and Hitzmann 2015).”
MethodVann, L., & Sheppard, J. (2017) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/s10295-017-1984-2 · Cited by 15
Chilmonczyk, M. A., Kottke, P. A., Stevens, H. Y., Guldberg, R. E., & Fedorov, A. G. (2018) · Biotechnology and Bioengineering · doi:10.1002/bit.26832 · Cited by 14
Towards Digital Twin for Biopharmaceutical Processes: Concept and Progress
Ding, C., Yang, O., & Ierapetritou, M. (2023) · Cell engineering · doi:10.1007/978-3-031-45669-5_6 · Cited by 20
Schlaugat, J., Patzer, K., Hentrop, T., Solle, D., Pepelanova, I., Schröder, U., & Scheper, T. H. (2020) · Engineering in Life Sciences · doi:10.1002/elsc.201900140 · Cited by 13
Self-citationNovel strategies for predictive particle monitoring and control using advanced image analysis
Nielsen, R. F., Kermani, N. A., Freiesleben, L. L. C., Gernaey, K. V., & Mansouri, S. S. (2019) · Computer-aided chemical engineering/Computer aided chemical engineering · doi:10.1016/b978-0-12-818634-3.50240-x · Cited by 13
Bridging process diversity in cell therapies toward standardization of manufacturing workflows
Costa, M. H. G., Carrondo, M. J. T., Alves, P. M., & Serra, M. (2026) · Cytotherapy · doi:10.1016/j.jcyt.2025.102041 · Cited by 12
Online Analysis for Industrial Bioprocesses
Veloso, A. C. A., & Ferreira, E. C. (2016) · Elsevier eBooks · doi:10.1016/b978-0-444-63663-8.00023-9 · Cited by 15
Assawajaruwan, S., Eckard, P., & Hitzmann, B. (2017) · Process Biochemistry · doi:10.1016/j.procbio.2017.05.007 · Cited by 12
Micro-Electromechanical Affinity Sensor for the Monitoring of Glucose in Bioprocess Media
Theuer, L., Lehmann, M., Junne, S. G., Neubauer, P. B., & Birkholz, M. (2017) · International Journal of Molecular Sciences · doi:10.3390/ijms18061235 · Cited by 12
Sensors for Disposable Bioreactor Systems
Steinwedel, T., Dahlmann, K., Solle, D., Scheper, T. H., Reardon, K. F., & Lammers, F. (2019) · Wiley eBooks · doi:10.1002/9781119477891.ch6 · Cited by 14
Self-citationProduction of Protein Therapeutics in the Quality by Design (QbD) Paradigm
Rathore, A. S., & Singh, S. K. (2016) · Topics in medicinal chemistry · doi:10.1007/7355_2015_5004 · Cited by 11
Bierer, B., Kreß, P., Nägele, H., Lemmer, A., & Palzer, S. (2019) · Engineering in Life Sciences · doi:10.1002/elsc.201900046 · Cited by 11
Kastenhofer, J., Libiseller-Egger, J., Rajamanickam, V., & Oliver Spadiut, A. (2021) · Processes · doi:10.3390/pr9030422 · Cited by 11
Pacheco, A. D., Delgado-Macuil, R. J., Pacheco, A. D., Corona, C. P. L., Girón, J. D. T., & y López, V. E. L. (2021) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-021-02572-0 · Cited by 11
“Biomass is one of the most important bioprocess variables, thus its monitoring is crucial [1].”
Background
Metadata
- Authors
- Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K.
- Affiliations
- Leibniz University Hannover (DE)
- Colorado State University (US)
- Corresponding author
- Solle, Dörte
- Venue
- Engineering in Life Sciences
- Publisher
- Wiley
- Published
- 2015-05-12
- Volume
- 15
- Issue
- 5
- Pages
- 469-488
- ISSN
- 1618-0240 (ISSN-L)
- 1618-2863
- OpenAlex
- W2085488202
- Semantic Scholar
- d24fffc6c68def0606d462a8628ed3175d254e61
- Cited by
- 224
- References
- 230
- Citations by year
- 2026: 27 · 2025: 22 · 2024: 17 · 2023: 17 · 2022: 23 · 2021: 23 · 2020: 22 · 2019: 24 · 2018: 14 · 2017: 22 · 2016: 10 · 2015: 3
- FWCI
- 15.12
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Engineering in Life Sciences (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Fluid Dynamics and Mixing
- Physical Sciences › Environmental Science › Waste Management and Disposal › Water Quality Monitoring and Analysis
- Keywords
- bioprocess monitoring, real-time process analysis, oxygen sensors, CO2 sensor, biosensors, flow injection analysis, spectroscopic sensors, chemometrics, soft sensors, disposable sensors, biopharmaceutical manufacturing, continuous biomanufacturing, quality by design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.