Abstract
The ability to measure all process variables is of great importance in the field of bioprocess monitoring and control, and continuous, real‐time measurements are highly desired. The more complete and real‐time the measurements are, the more stable, reproducible, and efficient the process can be, leading to reproducibly high‐quality products. This additional information allows the operator to better document the entire process. The process analytical technologies initiative of the US Food and Drug Administration is strongly related to the analysis and control of biopharmaceutical processes. The aim of the initiative is to create processes, generating products of ensured quality by measuring quality‐related process variables. The quality of the product is enhanced by a deep understanding of the process, which is enabled by an effective and suitable sensor system. The aim of this review is to provide an overview of current and emerging sensors for bioprocess monitoring. Sensors directly interfaced to bioreactors for measuring important variables from the gas phase, such as oxygen and carbon dioxide concentration, are discussed, as well as sensors for the monitoring of the biomass concentration and morphology and of the changing medium composition. Furthermore, sensor systems are discussed. These involve sensors (especially biosensors) that are not implemented directly inside the bioreactor but rather are used in conjunction with sample‐taking systems such as flow injection analysis. A major focus is given to spectroscopic sensors, which are noninvasive and offer interesting options for a simultaneous analysis of various compounds. Since data handling is extremely important for this kind of sensor, chemometrics are also included. Soft sensors are discussed as technology that allows a user to incorporate more process data as it become available. Finally, the current state of disposable sensor technology is presented. These sensors are needed for the growing area of disposable and continuous biomanufacturing.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498 · cited 2×
“Another approach uses the enzymes glucose/fructose oxidoreductase and gluconolactonase, immobilized upon a pH electrode, which determines the production of hydrogen ions resulting from the enzymatic turnover in presence of glucose [51, 58, 59].”
BackgroundMethodReview of the most common pre-processing techniques for near-infrared spectra
Rinnan, Å., Berg, F. V. D., & Engelsen, S. B. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.07.007 · Cited by 3,057 · cited 1×
“Filtering [190], centering, normalization, standardization, deviation [191], wavelength selection [192, 193], weighing, and scaling are common preprocessing methods for multivariate data [6, 194].”
MethodElectrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329 · cited 1×
“Other reviews focus on specific biosensor classes, including calorimetric [52, 55–57], optical [39, 41], and electrochemical biosensors [38, 43, 44].”
BackgroundData-driven Soft Sensors in the process industry
Kadlec, P., Gabrys, B., & Strandt, S. (2009) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2008.12.012 · Cited by 1,845 · cited 2×
“using mass preservation principles or energy balances) [223, 228].”
BackgroundMethodElectrochemical biosensors: recommended definitions and classification
Thévenot, D. R., Toth, K., Durst, R. A., & Wilson, G. S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00115-4 · Cited by 1,727
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Bioreactor scale-up and oxygen transfer rate in microbial processes: An overview
Garcia-Ochoa, F., & Gomez, E. (2009) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.10.006 · Cited by 1,504
Song, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
A review of near infrared spectroscopy and chemometrics in pharmaceutical technologies
Roggo, Y., Chalus, P., Maurer, L., Lema-Martinez, C., Edmond, A., & Jent, N. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.03.023 · Cited by 1,131
Ṙuz̆ic̆ka, J., & Hansen, E. H. (1975) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)84761-9 · Cited by 1,025
Borisov, S. M., & Wolfbeis, O. S. (2008) · Chemical Reviews · doi:10.1021/cr068105t · Cited by 1,018
Encyclopedia of analytical science
(2005) · Choice Reviews Online · doi:10.5860/choice.43-0032 · Cited by 917
Continuous Recording of Blood Oxygen Tensions by Polarography
Clark, L. C., Wolf, R., Granger, D., & Taylor, Z. (1953) · Journal of Applied Physiology · doi:10.1152/jappl.1953.6.3.189 · Cited by 886 · cited 1×
“Membrane-covered amperometric electrodes, known as Clark-type electrodes, are the most common type used [60, 83, 84].”
MethodReview of adaptation mechanisms for data-driven soft sensors
Kadlec, P., Grbić, R., & Gabrys, B. (2011) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2010.07.034 · Cited by 517 · cited 1×
“Unforeseen process changes that result in high process variances cannot be balanced by multivariate data analysis in every case [210, 231, 232], but some multivariable applications can be stabilized by soft sensors [228, 233, 234], adjusting the on-line prediction by a mathematical process model.”
BackgroundOxygen uptake rate in microbial processes: An overview
Garcia-Ochoa, F., Gomez, E., Santos, V. E., & Merchuk, J. C. (2010) · Biochemical Engineering Journal · doi:10.1016/j.bej.2010.01.011 · Cited by 511 · cited 1×
“Various methods for the determination of the OUR based on oxygen balance in the liquid phase or the whole reactor, as well as with variable (dynamic) or stable dissolved oxygen partial pressure, are known [179, 180].”
MethodMartens, H., Nielsen, J. P., & Engelsen, S. B. (2003) · Analytical Chemistry · doi:10.1021/ac020194w · Cited by 507 · cited 1×
“Filtering [190], centering, normalization, standardization, deviation [191], wavelength selection [192, 193], weighing, and scaling are common preprocessing methods for multivariate data [6, 194].”
MethodProbes and Polymers for Optical Sensing of Oxygen
Amao, Y. (2003) · Microchimica Acta · doi:10.1007/s00604-003-0037-x · Cited by 444 · cited 2×
“Amao reviewed several polymers as a possible matrix of optical oxygen sensors and various dye probes for oxygen sensing [93].”
BackgroundApplications of Raman spectroscopy in pharmaceutical analysis
Vankeirsbilck, T., Vercauteren, A., Baeyens, W., Van der Weken, G., Verpoort, F., Vergote, G., & Remon, J. P. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(02)01208-6 · Cited by 439
Duysens, L. N. M., & Amesz, J. (1957) · Biochimica et Biophysica Acta · doi:10.1016/0006-3002(57)90141-5 · Cited by 365
Nernst Limit in Dual-Gated Si-Nanowire FET Sensors
Knopfmacher, O., Tarasov, A., Fu, W., Wipf, M., Niesen, B., Calame, M., & Schönenberger, C. (2010) · Nano Letters · doi:10.1021/nl100892y · Cited by 353
Piezoelectric crystal biosensor modified with protein A for determination of immunoglobulins
Muramatsu, H., Dicks, J. M., Tamiya, E., & Karube, I. (1987) · Analytical Chemistry · doi:10.1021/ac00150a007 · Cited by 350 · cited 2×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodChemometrics in spectroscopy. Part 1. Classical chemometrics
Geladi, P. (2003) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/s0584-8547(03)00037-5 · Cited by 343
A systematic approach for soft sensor development
Lin, B., Recke, B., Knudsen, J. K. H., & Jørgensen, S. B. (2007) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2006.05.030 · Cited by 336
Abu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322 · cited 1×
“• ethanol / metabolic changes [117] • glutamine; glutamat [136]”
BackgroundCarbon Dioxide (CO2) Sensors for the Agri-food Industry—A Review
Neethirajan, S., Jayas, D. S., & Sadistap, S. (2009) · Food and Bioprocess Technology · doi:10.1007/s11947-008-0154-y · Cited by 320 · cited 1×
“The difference in absorption of infra-red (IR) light between the sample and reference (usually nitrogen) is measured by the detector and can be correlated to the gas concentration [13].”
BackgroundAutomatic Determination of Bacterioplankton Biomass by Image Analysis
Bjørnsen, P. K. (1986) · Applied and Environmental Microbiology · doi:10.1128/aem.51.6.1199-1204.1986 · Cited by 312 · cited 1×
“It is possible to acquire pictures of the suspended organisms and to analyze the cell concentration, cell size, cell distribution, and morphology automatically by image-processing algorithms [156].”
Bioreactor monitoring with spectroscopy and chemometrics: a review
Lourenço, N. D., Lopes, J. A., Almeida, C. F., Sarraguça, M. C., & Pinheiro, H. M. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6073-9 · Cited by 275 · cited 1×
“Data preprocessing is a sensitive and powerful tool for spectroscopic data [195].”
MethodRecent development and applications of optical and fiber-optic pH sensors
Lin, J. (2000) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(00)00034-0 · Cited by 271
Some common misunderstandings in chemometrics
Kjeldahl, K., & Bro, R. (2010) · Journal of Chemometrics · doi:10.1002/cem.1346 · Cited by 248 · cited 1×
“Further, data preprocessing can focus relevant information in the process data [196].”
BackgroundImpact of the cold shock phenomenon on quantification of intracellular metabolites in bacteria
Wittmann, C., Krömer, J. O., Kiefer, P., Binz, T., & Heinzle, E. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.01.002 · Cited by 241
Soft sensors in bioprocessing: A status report and recommendations
Luttmann, R., Bracewell, D. G., Cornelissen, G., Gernaey, K. V., Glassey, J., Hass, V. C., Kaiser, C., Preusse, C., Striedner, G., & Mandenius, C. (2012) · Biotechnology Journal · doi:10.1002/biot.201100506 · Cited by 238 · cited 1×
“using mass preservation principles or energy balances) [223, 228].”
MethodProtein Detection with Aptamer Biosensors
Strehlitz, B., Nikolaus, N., & Stoltenburg, R. (2008) · Sensors · doi:10.3390/s8074296 · Cited by 237
Matthijs, H. C. P., Balke, H., van Hes, U. M., Kroon, B. M. A., Mur, L. R., & Binot, R. A. (1996) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19960405)50:1<98::aid-bit11>3.0.co;2-3 · Cited by 226
Buchholz, A., Takors, R., & Wandrey, C. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5183 · Cited by 221
Real-time bioprocess monitoring
Vojinović, V., Cabral, J. M. S., & Fonseca, L. P. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.07.059 · Cited by 221
Equilibrium studies on colorimetric plastic film sensors for carbon dioxide
Mills, A., Chang, Q., & McMurray, N. (1992) · Analytical Chemistry · doi:10.1021/ac00037a015 · Cited by 219 · cited 2×
“Frequently used pH-sensitive indicators for absorbance are cresol red [96], phenol red, bromophenol blue, and chlorophenol red [97].”
BackgroundMetabolomics: quantification of intracellular metabolite dynamics
Buchholz, A., Hurlebaus, J., Wandrey, C., & Takors, R. (2002) · Biomolecular Engineering · doi:10.1016/s1389-0344(02)00003-5 · Cited by 215
Lange, H. C., Eman, M., van Zuijlen, G., Visser, D., van Dam, J. C., Frank, J., de Mattos, M. J. T., & Heijnen, J. J. (2001) · Biotechnology and Bioengineering · doi:10.1002/bit.10048 · Cited by 194
High-level production of 1,3-propanediol from crude glycerol by Clostridium butyricum AKR102a
Wilkens, E., Ringel, A. K., Hortig, D., Willke, T., & Vorlop, K.-D. (2012) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-011-3595-6 · Cited by 194
Two-Dimensional Fluorescence Spectroscopy: A New Tool for On-Line Bioprocess Monitoring
Marose, S., Lindemann, C., & Scheper, T. (1998) · Biotechnology Progress · doi:10.1021/bp970124o · Cited by 190
Self-citationCarvell, J. P., & Dowd, J. E. (2006) · Cytotechnology · doi:10.1007/s10616-005-3974-x · Cited by 184 · cited 2×
“ISM X X X [157, 158, 160–162, 183, 184] Optical density X X [145] Impedance X [149, 152, 164, 185] Calorimetry X X [165, 167, 168] NMR spectroscopy X [173, 174] OUR / RQ X X [176–179, 181, 182, 186, 187]”
BackgroundAutomated Sampling Device for Monitoring Intracellular Metabolite Dynamics
Schaefer, U., Boos, W., Takors, R., & Weuster-Botz, D. (1999) · Analytical Biochemistry · doi:10.1006/abio.1999.4048 · Cited by 183
Cervera, A. E., Petersen, N., Lantz, A. E., Larsen, A., & Gernaey, K. V. (2009) · Biotechnology Progress · doi:10.1002/btpr.280 · Cited by 175
Biomass measurement online: the performance of in situ measurements and software sensors
Kiviharju, K., Salonen, K., Moilanen, U., & Eerikäinen, T. (2008) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/s10295-008-0346-5 · Cited by 173
Spektroskopische Methoden in der organischen Chemie
(2012) · Thieme eBooks · doi:10.1055/b-002-46984 · Cited by 171
The use and misuse of chemometrics for treating classification problems
Defernez, M., & Kemsley, E. K. (1997) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(97)00015-0 · Cited by 168 · cited 1×
“With PCA, a classification of raw materials, batches, or the process status is also possible [197].”
MethodSensitivity, Selectivity and Stability of Gas-Sensitive Metal-Oxide Nanostructures
Bochenkov, V. E., & Сергеев, Г. Б. (2010) · Cited by 166
Spectral analysis and fingerprinting for biomedia characterisation
Pons, M.-N., Bonté, S. L., & Potier, O. (2004) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2004.03.028 · Cited by 161 · cited 1×
“The observable transitions take place at unsaturated bonds, such as in aromatics [115].”
BackgroundHarms, P. D., Kostov, Y. V., & Rao, G. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00295-1 · Cited by 160 · cited 2×
“Membrane-covered amperometric electrodes, known as Clark-type electrodes, are the most common type used [60, 83, 84].”
MethodWhelan, J., Craven, S., & Glennon, B. (2012) · Biotechnology Progress · doi:10.1002/btpr.1590 · Cited by 159 · cited 1×
“• TCD /VCD [138] • [114] BSA, celldebries”
Soft-sensor development for fed-batch bioreactors using support vector regression
Desai, K. M., Badhe, Y. P., Tambe, S. S., & Kulkarni, B. D. (2005) · Biochemical Engineering Journal · doi:10.1016/j.bej.2005.08.002 · Cited by 153 · cited 1×
“Supported vector machines separate the data by as much as possible [198, 199].”
BackgroundOptical sensor systems for bioprocess monitoring
Ulber, R., Frerichs, J.-G., & Beutel, S. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1930-1 · Cited by 151 · cited 3×
“Furthermore, these sensors must be cheap (owing to their single-use nature), small, and modular [89,94].”
BackgroundKaneko, H., Arakawa, M., & Funatsu, K. (2008) · AIChE Journal · doi:10.1002/aic.11648 · Cited by 151 · cited 1×
“Unforeseen process changes that result in high process variances cannot be balanced by multivariate data analysis in every case [210, 231, 232], but some multivariable applications can be stabilized by soft sensors [228, 233, 234], adjusting the on-line prediction by a mathematical process model.”
BackgroundIn‐situ near infrared spectroscopy to monitor key analytes in mammalian cell cultivation
Arnold, S. A., Crowley, J., Woods, N., Harvey, L. M., & McNeil, B. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10738 · Cited by 149
Upconverting nanoparticle based optical sensor for carbon dioxide
Ali, R., Saleh, S. M., Meier, R. J., Azab, H. A., Abdelgawad, I. I., & Wolfbeis, O. S. (2010) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2010.07.031 · Cited by 145 · cited 1×
“They are typically based on the fluorometric or colorimetric changes of pH-sensitive indicators that are added to the buffer system and separated from the analyte solution by a CO2-permeable membrane [100].”
BackgroundSoftware sensors in bioprocess engineering
Chéruy, A. (1997) · Journal of Biotechnology · doi:10.1016/s0168-1656(96)01644-6 · Cited by 142 · cited 1×
“A soft sensor combines a measuring part (sensor) and a softwarebased estimation algorithm for on-line monitoring [222].”
MethodIn situ sensor techniques in modern bioprocess monitoring
Beutel, S., & Henkel, S. (2011) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-011-3470-5 · Cited by 136 · cited 8×
“The NIR range is thus suitable for monitoring of substrates such as glucose and lactate, biomass, and the products of a bioprocess [89, 122].”
BackgroundInfluentialOn-line infrared spectroscopy for bioprocess monitoring
Landgrebe, D., Haake, C., Höpfner, T., Beutel, S., Hitzmann, B., Scheper, T., Rhiel, M., & Reardon, K. F. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2743-8 · Cited by 134 · cited 5×
“The NIR range is thus suitable for monitoring of substrates such as glucose and lactate, biomass, and the products of a bioprocess [89, 122].”
BackgroundSelf-citationTechniques for oxygen transfer measurement in bioreactors: a review
Suresh, S., Srivastava, V., & Mishra, I. (2009) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.2154 · Cited by 130 · cited 2×
“The difference between the oxygen concentration in the off gas and an external air reference results in an electrical resistance change correlating to the oxygen concentration [10].”
BackgroundGnoth, S., Jenzsch, M., Simutis, R., & Lübbert, A. (2007) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2007.03.020 · Cited by 127
Kamen, A. A., Bédard, C., Tom, R., Perret, S., & Jardin, B. (1996) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19960405)50:1<36::aid-bit5>3.0.co;2-2 · Cited by 127
In-situ microscopy: Online process monitoring of mammalian cell cultures
Joeris, K., Frerichs, J.-G., Konstantinov, K., & Scheper, T. H. (2002) · Cytotechnology · doi:10.1023/a:1021170502775 · Cited by 125
Self-citationHao, X., Wang, Q., Zhang, X., Cao, Y., & van Loosdrecht, M. C. M. (2009) · Water Research · doi:10.1016/j.watres.2009.05.019 · Cited by 125
Near Infrared Spectroscopy for Bioprocess Monitoring and Control: Current Status and Future Trends
Scarff, M., Arnold, S. A., Harvey, L. M., & McNeil, B. (2006) · Critical Reviews in Biotechnology · doi:10.1080/07388550500513677 · Cited by 124
Park, S.-Y., & Han, C. (2000) · Computers & Chemical Engineering · doi:10.1016/s0098-1354(00)00343-4 · Cited by 123 · cited 1×
“Unforeseen process changes that result in high process variances cannot be balanced by multivariate data analysis in every case [210, 231, 232], but some multivariable applications can be stabilized by soft sensors [228, 233, 234], adjusting the on-line prediction by a mathematical process model.”
BackgroundCalorimetric investigation of aerobic fermentations
Birou, B., Marison, I. W., & Stockar, U. V. (1987) · Biotechnology and Bioengineering · doi:10.1002/bit.260300509 · Cited by 121
On-Line Fermentation Monitoring by Mid-Infrared Spectroscopy
Mazarevica, G., Diewok, J., Baena, J. R., Rosenberg, E., & Lendl, B. (2004) · Applied Spectroscopy · doi:10.1366/0003702041389229 · Cited by 121 · cited 1×
“• ethanol [108] • glucose; lactate [110]”
Process analytical technology: a critical view of the chemometricians
Pomerantsev, A. L., & Rodionova, O. Y. (2012) · Journal of Chemometrics · doi:10.1002/cem.2445 · Cited by 119 · cited 14×
“PAT is a regulatory initiative introduced by the FDA to improve the understanding of production processes and to increase the quality of the final product by building this quality into the entire production process.”
MethodInfluentialSivakesava, S., Irudayaraj, J., & Demırcı, A. (2001) · Process Biochemistry · doi:10.1016/s0032-9592(01)00223-0 · Cited by 119 · cited 1×
“Filtering [190], centering, normalization, standardization, deviation [191], wavelength selection [192, 193], weighing, and scaling are common preprocessing methods for multivariate data [6, 194].”
MethodFuture Aspects of Bioprocess Monitoring
Becker, T. M., Hitzmann, B., Muffler, K., Pörtner, R., Reardon, K. F., Stahl, F., & Ulber, R. (2006) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2006_036 · Cited by 115 · cited 1×
“It is based on shifted wavelength scattering of molecules, after excitation by monochromatic light, usually produced by adjustable lasers [42].”
BackgroundSelf-citationRuffieux, P.-A., von Stockar, U., & Marison, I. W. (1998) · Journal of Biotechnology · doi:10.1016/s0168-1656(98)00046-7 · Cited by 114 · cited 1×
“Various methods for the determination of the OUR based on oxygen balance in the liquid phase or the whole reactor, as well as with variable (dynamic) or stable dissolved oxygen partial pressure, are known [179, 180].”
MethodIn situ microscopy for on-line determination of biomass
Bittner, C., Wehnert, G., & Scheper, T. (1998) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19981005)60:1<24::aid-bit3>3.0.co;2-2 · Cited by 114
Self-citationDevelopment of an On-line Glucose Sensor for Fermentation Monitoring
Brooks, S. L., Ashby, R. E., Turner, A. P. F., Calder, M. R., & Clarke, D. J. (1987) · Biosensors · doi:10.1016/0265-928x(87)80012-3 · Cited by 112 · cited 4×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodInfluentialPrinciples and Applications of Biosensors for Bioprocess Monitoring and Control
Mulchandani, A., & Bassi, A. S. (1995) · Critical Reviews in Biotechnology · doi:10.3109/07388559509147402 · Cited by 110 · cited 1×
“Other reviews focus on specific biosensor classes, including calorimetric [52, 55–57], optical [39, 41], and electrochemical biosensors [38, 43, 44].”
BackgroundThe potential of mid infrared spectroscopy (MIRS) for real time bioprocess monitoring
Roychoudhury, P., Harvey, L. M., & McNeil, B. W. J. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.086 · Cited by 107 · cited 2×
“However, in-line measurement in aqueous solutions is possible using appropriate fiber optic probes that incorporate attenuated total reflection (ATR) technology and Fourier transformation [14, 121, 122].”
BackgroundThe use of calorimetry in biotechnology
von Stockar, U., & Marison, I. W. (1989) · Advances in biochemical engineering, biotechnology · doi:10.1007/bfb0009829 · Cited by 106 · cited 1×
“ISM X X X [157, 158, 160–162, 183, 184] Optical density X X [145] Impedance X [149, 152, 164, 185] Calorimetry X X [165, 167, 168] NMR spectroscopy X [173, 174] OUR / RQ X X [176–179, 181, 182, 186, 187]”
Hanson, M. A., Ge, X., Kostov, Y., Brorson, K. A., Moreira, A. R., & Rao, G. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21320 · Cited by 106 · cited 1×
“They showed that optical sensors enabled small-scale monitoring and that the measurement results are comparable to standard electrochemical probes [95].”
BackgroundIn situ bioprocess monitoring of Escherichia coli bioreactions using Raman spectroscopy
Lee, H., Boccazzi, P., Gorret, N., Ram, R. J., & Sinskey, A. J. (2004) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2003.12.015 · Cited by 106
Systematic Investigation of Optimal Aptamer Immobilization for Protein−Microarray Applications
Walter, J., Kökpınar, Ö., Friehs, K., Stahl, F., & Scheper, T. H. (2008) · Analytical Chemistry · doi:10.1021/ac801081v · Cited by 103
Self-citationThe enzyme thermistor—A realistic biosensor concept. A critical review
Yakovleva, M., Bhand, S., & Danielsson, B. R. G. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.12.004 · Cited by 103
Neurauter, G., Klimant, I., & Wolfbeis, O. S. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(98)00748-x · Cited by 100 · cited 1×
“The protonation of the pH-sensitive fluorophore initiates a reversible reaction, which results in a change of the fluorescence, which correlates to the CO2 concentration [101, 102].”
BackgroundA flow injection analysis system for fermentation monitoring and control
Garn, M. B., Gisin, M., Thommen, C., & Cevey, P. (1989) · Biotechnology and Bioengineering · doi:10.1002/bit.260340402 · Cited by 100
Ödman, P., Johansen, C. L., Lisbeth Olsson, A., Gernaey, K. V., & Lantz, A. E. (2009) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2009.08.018 · Cited by 100
Phase fluorometric sterilizable optical oxygen sensor
Bambot, S. B., Holavanahali, R., Lakowicz, J. R., Carter, G. M., & Rao, G. (1994) · Biotechnology and Bioengineering · doi:10.1002/bit.260431119 · Cited by 98
The effect of dissolved oxygen tension and the utility of oxygen uptake rate in insect cell culture
Palomares, L. A., & Ramírez, O. T. (1996) · Cytotechnology · doi:10.1007/bf00353943 · Cited by 93
Suhr, H., Wehnert, G., Schneider, K., Bittner, C., Scholz, T., Geissler, P., Jähne, B., & Scheper, T. (1995) · Biotechnology and Bioengineering · doi:10.1002/bit.260470113 · Cited by 92
Self-citationMultivariate statistical process control based on multiway locality preserving projections
Hu, K., & Yuan, J. (2008) · Journal of Process Control · doi:10.1016/j.jprocont.2007.11.002 · Cited by 91
On-line Multisensor Monitoring of Yogurt and Filmjölk Fermentations on Production Scale
Navrátil, M., Cimander, C., & Mandenius, C. (2004) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0304876 · Cited by 91
A long-range fiber optic pH sensor prepared by dye doped sol-gel immobilization technique
Gupta, B. D., & Sharma, S. (1998) · Optics Communications · doi:10.1016/s0030-4018(98)00321-6 · Cited by 90 · cited 3×
“To increase the dynamic range, Gupta and Sharma [97] presented a long-range fiber optic pH sensor based on evanescent wave absorption.”
BackgroundIn situ 2D fluorometry and chemometric monitoring of mammalian cell cultures
Teixeira, A. P., Portugal, C. A. M., Carinhas, N., Dias, J. M. L., Crespo, J. P., Alves, P. M., Carrondo, M. J. T., & Oliveira, R. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22125 · Cited by 90
Quantification of intracellular amino acids in batch cultures of Saccharomyces cerevisiae
Hans, M. A., Heinzle, E., & Wittmann, C. (2001) · Applied Microbiology and Biotechnology · doi:10.1007/s002530100708 · Cited by 88
Navrátil, M., Norberg, A., Lembrén, L., & Mandenius, C. (2004) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2004.07.013 · Cited by 87
Roychoudhury, P., Harvey, L. M., & McNeil, B. W. J. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.01.037 · Cited by 85 · cited 2×
“Herewith, the values of different variables can be predicted from a spectroscopic measurement by adapted chemometric models for each variable [111,210].”
BackgroundEstimation of biomass concentrations in fermentation processes for recombinant protein production
Jenzsch, M., Simutis, R., Eisbrenner, G., Stückrath, I., & Lübbert, A. (2006) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-006-0051-6 · Cited by 84 · cited 1×
“This type of soft sensor uses chemometric techniques such as PLS, PCA, and NNs to describe the internal relationships between measured process data and various process variables [224,226,227].”
MethodChalla, S., & Potumarthi, R. (2012) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-012-9950-y · Cited by 83 · cited 14×
“PAT is a regulatory initiative introduced by the FDA to improve the understanding of production processes and to increase the quality of the final product by building this quality into the entire production process.”
MethodInfluentialRhiel, M., Ducommun, P., Bolzonella, I., Marison, I., & von Stockar, U. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10134 · Cited by 83
Model optimization of SVM for a fermentation soft sensor
Liu, G., Zhou, D., Xu, H., & Mei, C. (2009) · Expert Systems with Applications · doi:10.1016/j.eswa.2009.08.008 · Cited by 82 · cited 1×
“Supported vector machines separate the data by as much as possible [198, 199].”
BackgroundAdvances in process monitoring tools for cell culture bioprocesses
Zhao, L., Fu, H., Zhou, W., & Hu, W. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500006 · Cited by 81
High-stability non-invasive autoclavable naked optical CO2 sensor
Ge, X., Kostov, Y. V., & Rao, G. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00159-8 · Cited by 81 · cited 1×
“The protonation of the pH-sensitive fluorophore initiates a reversible reaction, which results in a change of the fluorescence, which correlates to the CO2 concentration [101, 102].”
BackgroundFermentanomics: Monitoring Mammalian Cell Cultures with NMR Spectroscopy
Bradley, S. A., Ouyang, A., Purdie, J., Smitka, T. A., Wang, T., & Kaerner, A. (2010) · Journal of the American Chemical Society · doi:10.1021/ja101962c · Cited by 80 · cited 1×
“ISM X X X [157, 158, 160–162, 183, 184] Optical density X X [145] Impedance X [149, 152, 164, 185] Calorimetry X X [165, 167, 168] NMR spectroscopy X [173, 174] OUR / RQ X X [176–179, 181, 182, 186, 187]”
Two-dimensional fluorescence spectroscopy: A novel approach for controlling fed-batch cultivations
Hantelmann, K., Kollecker, M., Hüll, D., Hitzmann, B., & Scheper, T. (2006) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.07.016 · Cited by 80 · cited 2×
“• ethanol / metabolic changes [117] • glutamine; glutamat [136]”
BackgroundSelf-citationGeneric model control of the specific growth rate in recombinant Escherichia coli cultivations
Jenzsch, M., Simutis, R., & Luebbert, A. (2005) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.09.013 · Cited by 79 · cited 1×
“Sensors based on the use of Kalman filters or extended Kalman filters are commonly applied in this field of soft sensing [229, 230].”
MethodClavaud, M., Roggo, Y., Daeniken, R. V., Liebler, A., & Schwabe, J. O. (2013) · Talanta · doi:10.1016/j.talanta.2013.03.044 · Cited by 78
NMR for microbiology: In vivo and in situ applications
Grivet, J., & Delort, A. M. (2008) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2008.02.001 · Cited by 77 · cited 1×
“2 NMR spectroscopy Alternatively, NMR spectroscopy allows the direct measurement of different intracellular components such as metabolic intermediates, amino acids, ammonia, intracellular pH, Ca+ and Na+, adenosine-triphosphate, and NAD(P)H [2, 171, 172].”
BackgroundZou, X., Hang, H., Chu, J., Zhuang, Y., & Zhang, S. (2008) · Bioresource Technology · doi:10.1016/j.biortech.2008.09.017 · Cited by 76
Measurement, Monitoring, Modelling and Control of Bioprocesses
Mandenius, C., & Titchener-Hooker, N. J. (2013) · Advances in biochemical engineering, biotechnology · doi:10.1007/978-3-642-36838-7 · Cited by 75
Zafar, S., D'Emic, C. P., Afzali, A., Fletcher, B. J., Zhu, Y., & Ning, T. H. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/40/405501 · Cited by 74
Large-scale calorimetry and biotechnology
von Stockar, U., & Marison, I. W. (1991) · Thermochimica Acta · doi:10.1016/0040-6031(91)80185-l · Cited by 73
Kessler, R. W. (2006) · Wiley eBooks · doi:10.1002/3527608990 · Cited by 73
In-situ imaging sensors for bioprocess monitoring: state of the art
Bluma, A., Höpfner, T., Lindner, P., Rehbock, C., Beutel, S., Riechers, D., Hitzmann, B., & Scheper, T. H. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-4181-y · Cited by 72 · cited 1×
“The cells are dispersed as a solid phase in a liquid medium phase, which is aerated by a gas phase [1].”
BackgroundSelf-citationOn‐line monitoring of Phaffia rhodozyma fed‐batch process with in situ dispersive raman spectroscopy
Cannizzaro, C., Rhiel, M., Marison, I., & von Stockar, U. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10698 · Cited by 70
Dielectric monitoring of growth and sporulation of Bacillus thuringiensis
Sarrafzadeh, M., Belloy, L., Esteban, G., Navarro, J. M., & Ghommidh, C. (2005) · Biotechnology Letters · doi:10.1007/s10529-005-2543-x · Cited by 69 · cited 1×
“ISM X X X [157, 158, 160–162, 183, 184] Optical density X X [145] Impedance X [149, 152, 164, 185] Calorimetry X X [165, 167, 168] NMR spectroscopy X [173, 174] OUR / RQ X X [176–179, 181, 182, 186, 187]”
Application of Scanning Fluorometry for Monitoring of a Fermentation Process
Tartakovsky, B., Sheintuch, M., Hilmer, J.-M., & Scheper, T. (1996) · Biotechnology Progress · doi:10.1021/bp950045h · Cited by 69
Self-citationSandor, M., Rüdinger, F., Bienert, R., Grimm, C., Solle, D., & Scheper, T. H. (2013) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2013.08.002 · Cited by 68
Self-citationClementschitsch, F., Jürgen, K., Pötschacher, F., & Karl, B. (2005) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2005.05.030 · Cited by 68 · cited 1×
“Different measurements, multivariate spectroscopic data, or univariate classical process data can be pooled [208] to generate a holistic view of the bioprocess.”
BackgroundHaack, M. B., Lantz, A. E., & Lisbeth Olsson, A. (2004) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2004.05.009 · Cited by 67
Glucose sensor using immobilized whole cells of Pseudomonas fluorescens
Karube, I., Mitsuda, S., & Suzuki, S. (1979) · Applied Microbiology and Biotechnology · doi:10.1007/bf00499848 · Cited by 67 · cited 1×
“Another approach uses the enzymes glucose/fructose oxidoreductase and gluconolactonase, immobilized upon a pH electrode, which determines the production of hydrogen ions resulting from the enzymatic turnover in presence of glucose [51, 58, 59].”
MethodOn-line biomass measurements in bioreactor cultivations: comparison study of two on-line probes
Kiviharju, K., Salonen, K., Moilanen, U., Meskanen, E., Leisola, M., & Eerikäinen, T. (2007) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/s10295-007-0233-5 · Cited by 66
Sensors in Disposable Bioreactors Status and Trends
Glindkamp, A., Riechers, D., Rehbock, C., Hitzmann, B., Scheper, T., & Reardon, K. F. (2009) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/10_2009_10 · Cited by 65 · cited 17×
“PAT is a regulatory initiative introduced by the FDA to improve the understanding of production processes and to increase the quality of the final product by building this quality into the entire production process.”
BackgroundSelf-citationHakemeyer, C., Strauss, U. T., Werz, S., José, G. E., Folque, F., & de Menezes, J. C. (2011) · Talanta · doi:10.1016/j.talanta.2011.12.042 · Cited by 65 · cited 1×
“NIR spectroscopy offer a more global view to a bioprocess, for example, by batch trajectory [125].”
BackgroundChemometrics applications in biotech processes: A review
Rathore, A. S., Bhushan, N., & Hadpe, S. R. (2011) · Biotechnology Progress · doi:10.1002/btpr.561 · Cited by 65 · cited 1×
“It cannot be found in a subset of a spectrum nor in only one spectrum [188, 189].”
BackgroundFrahm, B., Blank, H.-C., Cornand, P., Oelßner, W., Guth, U., Lane, P., Munack, A., Johannsen, K., & Pörtner, R. (2002) · Journal of Biotechnology · doi:10.1016/s0168-1656(02)00180-3 · Cited by 65
Guez, J. S., Cassar, J. P., Wartelle, F., Dhulster, P., & Suhr, H. (2004) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2004.04.028 · Cited by 64
Koch, C., Posch, A. E., Goicoechea, H. C., Herwig, C., & Lendl, B. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.10.042 · Cited by 63 · cited 1×
“Pilot tests, spiking experiments, and data from experimental design allow one to construct premodels, which can be adjusted and validated by process data [213, 214].”
MethodBioanalytics: detailed insight into bioprocesses
Scheper, T. H., Hitzmann, B., Stärk, E., Ulber, R., Faurie, R., Sosnitza, P., & Reardon, K. F. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00612-1 · Cited by 62 · cited 1×
“photodiode) is connected to the other end of the fiber [3,91].”
Self-citationCamisard, V., Brienne, J. ‐., Baussart, H., Hammann, J., & Suhr, H. (2002) · Biotechnology and Bioengineering · doi:10.1002/bit.10178 · Cited by 62
Boehl, D. (2003) · Journal of Biotechnology · doi:10.1016/s0168-1656(03)00189-5 · Cited by 62
Evaluation of a dialysis probe for continuous sampling in fermentors and in complex media
Mandenius, C., Danielsson, B. R. G., & Mattìasson, B. (1984) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)81502-0 · Cited by 61 · cited 1×
“A carrier buffer stream circulates at the inner permeate site of this membrane [20, 36, 37].”
BackgroundBäcker, M., Rakowski, D., Poghossian, A., Biselli, M., Wagner, P., & Schöning, M. J. (2012) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2012.03.014 · Cited by 61 · cited 1×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodJunker, B., Reddy, J., Gbewonyo, K., & Greasham, R. (1994) · Bioprocess and Biosystems Engineering · doi:10.1007/bf00369530 · Cited by 60 · cited 1×
“ISM X X X [157, 158, 160–162, 183, 184] Optical density X X [145] Impedance X [149, 152, 164, 185] Calorimetry X X [165, 167, 168] NMR spectroscopy X [173, 174] OUR / RQ X X [176–179, 181, 182, 186, 187]”
Sellick, C. A., Hansen, R., Jarvis, R. M., Maqsood, A. R., Stephens, G. M., Dickson, A. J., & Goodacre, R. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22707 · Cited by 60
Ansorge, S., Esteban, G., & Schmid, G. (2010) · Cytotechnology · doi:10.1007/s10616-010-9267-z · Cited by 59 · cited 1×
“Impedance measurement works best with large cells like CHO cells but is limited by the conductivity of the culture medium and must be calibrated for each biological system [154].”
BackgroundSoftware sensors for fermentation processes
Sundström, H., & Enfors, S. (2007) · Bioprocess and Biosystems Engineering · doi:10.1007/s00449-007-0157-5 · Cited by 57
de Vargas-Sansalvador, I. M. P., Fay, C., Phelan, T. J., Fernández-Ramos, M. D., Capitán-Vallvey, L. F., Diamond, D., & Benito‐Lopez, F. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.05.019 · Cited by 56 · cited 1×
“Furthermore, the analysis of carbon dioxide via this approach is affected by other IR-active gases such as methane [15].”
BackgroundKornmann, H., Rhiel, M., Cannizzaro, C., Marison, I., & von Stockar, U. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10618 · Cited by 56
A hybrid asymptotic-Kalman observer for bioprocesses
Bogaerts, P. (1999) · Bioprocess Engineering · doi:10.1007/s004490050587 · Cited by 55 · cited 1×
“Sensors based on the use of Kalman filters or extended Kalman filters are commonly applied in this field of soft sensing [229, 230].”
MethodBiosensors in bioprocess monitoring
Scheper, T. H., Hilmer, J., Lammers, F., Müller, C., & Reinecke, M. (1996) · Journal of Chromatography A · doi:10.1016/0021-9673(95)00998-1 · Cited by 54
Self-citationRemoval of U and Mo from water by immobilizedDesulfovibrio desulfuricans in column reactors
Tucker, M. D., Barton, L. L., & Thomson, B. M. (1998) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(19981005)60:1<88::aid-bit10>3.0.co;2-4 · Cited by 53
Rhee, J. I., & Kang, T.-H. (2007) · Process Biochemistry · doi:10.1016/j.procbio.2007.05.007 · Cited by 52
On-line monitoring and control of fermentation processes by flow-injection analysis
Forman, L. W., Thomas, B. D., & Jacobson, F. S. (1991) · Analytica Chimica Acta · doi:10.1016/0003-2670(91)87013-w · Cited by 52
Instrumentation of Biotechnological Processes
Sonnleitner, B. (1999) · Advances in biochemical engineering, biotechnology · doi:10.1007/3-540-48773-5_1 · Cited by 52
Alcohol biosensing by polyamidoamine (PAMAM)/cysteamine/alcohol oxidase‐modified gold electrode
Akin, M., Yuksel, M., Geyik, C., Demirkol, D. O., Bluma, A., Höpfner, T., Beutel, S., Scheper, T. H., & Tımur, S. (2010) · Biotechnology Progress · doi:10.1002/btpr.372 · Cited by 51 · cited 2×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodSelf-citationScheper, T., Lorenz, T., SCHMIDT, W., & Schügerl, K. (1987) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1987.tb23839.x · Cited by 50
Self-citationFermentation monitoring and control by on-line flow injection and liquid chromatography
Schügerl, K., Brandes, L., Dullau, T., Holzhauer-Rieger, K., Hotop, S., Hübner, U., Wu, X., & Zhou, W. (1991) · Analytica Chimica Acta · doi:10.1016/0003-2670(91)87012-v · Cited by 49 · cited 1×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodMarison, I. W., & von Stockar, U. (1986) · Biotechnology and Bioengineering · doi:10.1002/bit.260281205 · Cited by 49
Applications of biosensor systems for bioprocess monitoring
Scheper, T. H., Brandes, W., Grau, C., Hundeck, H. G., Reinhardt, B., Rüther, F., Plötz, F., Schelp, C., Schügerl, K., Schneider, K., et al. (1991) · Analytica Chimica Acta · doi:10.1016/0003-2670(91)87004-q · Cited by 49
Self-citationOn-line monitoring of lipid storage in yeasts using impedance spectroscopy
Maskow, T., Röllich, A., Fetzer, I., Ackermann, J., & Harms, H. (2008) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2008.02.014 · Cited by 49
Berríos, J., Altamirano, C., Osses, N., & González, R. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2011.03.011 · Cited by 49 · cited 1×
“RQ allows one to make inferences about substrate utilization rates of the culture and has been proposed as a valuable parameter for monitoring and controlling cell cultures [14, 181, 182].”
BackgroundBioprocess and Fermentation Monitoring
Pohlscheidt, M., Charaniya, S., Bork, C., Jenzsch, M., Noetzel, T. L., & Luebbert, A. (2013) · Wiley eBooks · doi:10.1002/9780470054581.eib606.pub2 · Cited by 48
A new set up for multi-analyte sensing: At-line bio-process monitoring
Akin, M., Prediger, A., Yuksel, M., Höpfner, T., Demirkol, D. O., Beutel, S., Tımur, S., & Scheper, T. H. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.018 · Cited by 48 · cited 4×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodSelf-citationEvaluation and applications of optical cell density probes in mammalian cell bioreactors
Wu, P., Ozturk, S. S., Blackie, J. D., Thrift, J., Figueroa, C., & Naveh, D. (1995) · Biotechnology and Bioengineering · doi:10.1002/bit.260450606 · Cited by 48 · cited 1×
“Backscattering probes show better results at cell concentrations up to 20 × 10(6) cells/mL in comparison to transmission probes [148].”
BackgroundSato, K., Yoshida, Y., Hirahara, T., & Toshiteru, O. H. B. A. (2000) · Journal of Bioscience and Bioengineering · doi:10.1016/s1389-1723(00)80084-5 · Cited by 47
Buttler, T., Nilsson, C., Gorton, L. G. O., Marko‐Varga, G., & Laurell, T. (1996) · Journal of Chromatography A · doi:10.1016/0021-9673(95)01120-x · Cited by 47 · cited 1×
“A carrier buffer stream circulates at the inner permeate site of this membrane [20, 36, 37].”
BackgroundDremel, B. A. A., Li, S.-Y., & Schmid, R. D. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)90018-i · Cited by 47 · cited 1×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodFast sampling and quenching procedures for microbial metabolic profiling
Hiller, J., Franco‐Lara, E., Papaioannou, V., & Weuster‐Botz, D. (2007) · Biotechnology Letters · doi:10.1007/s10529-007-9383-9 · Cited by 47
On-line calorimetry as a technique for process monitoring and control in biotechnology
von Stockar, U., Duboc, P., Menoud, L., & Marison, I. W. (1997) · Thermochimica Acta · doi:10.1016/s0040-6031(97)00055-5 · Cited by 47
Abu-Absi, N. R., Martel, R. P., Lanza, A. M., Clements, S. J., Borys, M. C., & Li, Z. J. (2014) · Pharmaceutical Bioprocessing · doi:10.4155/pbp.14.24 · Cited by 47 · cited 1×
“The use of Raman spectroscopy is limited by the strong fluorescence activity of several biological molecules in the culture broth [142].”
BackgroundAptasensors for Small Molecule Detection
Walter, J., Heilkenbrinker, A., Austerjost, J., Tımur, S., Stahl, F., & Scheper, T. H. (2012) · Zeitschrift für Naturforschung B · doi:10.5560/znb.2012-0147 · Cited by 47
Self-citationUse of spectroscopic data for automation in food processing industry
Ghosh, P. K., & Jayas, D. S. (2009) · Sensing and Instrumentation for Food Quality and Safety · doi:10.1007/s11694-008-9068-7 · Cited by 46 · cited 1×
“There has been a considerable effort to produce such a representative data basis for process variables and corresponding spectroscopic data [211, 212].”
BackgroundSampling Tube Device for Monitoring Intracellular Metabolite Dynamics
Weuster‐Botz, D. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2009 · Cited by 46
Warth, B., Rajkai, G., & Mandenius, C. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.02.023 · Cited by 45 · cited 2×
“NIR spectroscopy can be used to determine biomass and the specific growth rate [224].”
MethodHolzhauer-Rieger, K., Zhou, W., & Schügerl, K. (1990) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)97005-5 · Cited by 45
Optical Instrumentation for Bioprocess Monitoring
Lam, H., & Kostov, Y. V. (2009) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2008_50 · Cited by 44 · cited 7×
“[102] Ge, X., Kostov, Y., Rao, G., High-stability non-invasive autoclavable naked optical CO2 sensor.”
BackgroundInfluentialHikuma, M., Obana, H., Yasuda, T., Karube, I., & Suzuki, S. (1980) · Enzyme and Microbial Technology · doi:10.1016/0141-0229(80)90053-8 · Cited by 44 · cited 1×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodCleland, N., & Enfors, S. (1983) · Applied Microbiology and Biotechnology · doi:10.1007/bf00498035 · Cited by 43 · cited 2×
“Often, classical oxygen electrodes [50], or pH electrodes [51] are used.”
BackgroundMethodSampling and sample handling — crucial steps in process monitoring and control
Mattìasson, B., & Håkanson, H. (1993) · Trends in biotechnology · doi:10.1016/0167-7799(93)90088-q · Cited by 41 · cited 2×
“A carrier buffer stream circulates at the inner permeate site of this membrane [20, 36, 37].”
BackgroundChemometric Modelling based on 2D-Fluorescence Spectra without a Calibration Measurement
Solle, D., Geissler, D., Stärk, E., Scheper, T., & Hitzmann, B. (2003) · Bioinformatics · doi:10.1093/bioinformatics/19.2.173 · Cited by 41 · cited 1×
“There has been a considerable effort to produce such a representative data basis for process variables and corresponding spectroscopic data [211, 212].”
BackgroundSelf-citationNMR bioreactor development for live in-situ microbial functional analysis
Majors, P. D., McLean, J. S., & Scholten, J. C. M. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.02.014 · Cited by 40 · cited 1×
“Important drawbacks of this technology are the high prices for the hardware, the general technical setup, the need for high biomass concentrations, small measurement volumes, and long measurement periods [175].”
BackgroundReal time in-line monitoring of large scale Bacillus fermentations with near-infrared spectroscopy
Alves-Rausch, J., Bienert, R., Grimm, C., & Bergmaier, D. (2014) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2014.09.004 · Cited by 38 · cited 1×
“High process reproducibility and product safety can be provided by this type of process supervision [203].”
BackgroundRank, M., Gram, J., & Danielsson, B. R. G. (1993) · Analytica Chimica Acta · doi:10.1016/0003-2670(93)85010-h · Cited by 37 · cited 1×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodDevelopment of a high resolution UV spectrophotometer for at-line monitoring of bioprocesses
Noui, L., Hill, J., Keay, P. J., Wang, R. Y., Smith, T., Yeung, K. S. Y., Habib, G., & Hoare, M. (2002) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/s0255-2701(01)00122-2 · Cited by 37 · cited 2×
“• TCD /VCD [138] • [114] BSA, celldebries”
Backgroundda Luz, J. A., Hans, E., & Zeng, A. (2013) · Engineering in Life Sciences · doi:10.1002/elsc.201300099 · Cited by 37
Assessment of near infrared and “software sensor” for biomass monitoring and control
Soons, Z. I. T. A., Streefland, M., Straten, G. V., & van Boxtel, A. J. B. (2008) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2008.07.009 · Cited by 37 · cited 1×
“Filtering [190], centering, normalization, standardization, deviation [191], wavelength selection [192, 193], weighing, and scaling are common preprocessing methods for multivariate data [6, 194].”
MethodSarrafzadeh, M., Guiraud, J. P., Lagneau, C., Gaven, B., Carron, A., & Navarro, J. M. (2005) · Current Microbiology · doi:10.1007/s00284-005-4463-3 · Cited by 37 · cited 1×
“For example, the differentiation between growing, sporulating, and mature spores of Bacillus thuringiensis during endotoxin production was tracked using impendence data [153].”
MethodOptical Sensor Systems in Biotechnology
Rao, G. (2009) · Advances in biochemical engineering, biotechnology · doi:10.1007/978-3-642-03470-1 · Cited by 35
Kaiser, C., Pototzki, T., Ellert, A., & Luttmann, R. (2008) · Engineering in Life Sciences · doi:10.1002/elsc.200720232 · Cited by 35 · cited 2×
“ISM X X X [157, 158, 160–162, 183, 184] Optical density X X [145] Impedance X [149, 152, 164, 185] Calorimetry X X [165, 167, 168] NMR spectroscopy X [173, 174] OUR / RQ X X [176–179, 181, 182, 186, 187]”
MethodTwo FIA-based biosensor systems studied for bioprocess monitoring
Scheper, T., Brandes, W., Maschke, H. E., Plötz, F., & Müller, C. (1993) · Journal of Biotechnology · doi:10.1016/0168-1656(93)90079-3 · Cited by 35 · cited 2×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodSelf-citationIn situ proton-NMR analyses of Escherichia coli HB101 fermentations in 1H2O and in D2O
Brecker, L., Weber, H., Griengl, H., & Ribbons, D. W. (1999) · Microbiology · doi:10.1099/00221287-145-12-3389 · Cited by 35 · cited 1×
“ISM X X X [157, 158, 160–162, 183, 184] Optical density X X [145] Impedance X [149, 152, 164, 185] Calorimetry X X [165, 167, 168] NMR spectroscopy X [173, 174] OUR / RQ X X [176–179, 181, 182, 186, 187]”
Xiong, Z., Guo, M., Guo, Y., Chu, J., Zhuang, Y., Wang, N. S., & Zhang, S. (2010) · Enzyme and Microbial Technology · doi:10.1016/j.enzmictec.2010.03.003 · Cited by 34 · cited 1×
“RQ allows one to make inferences about substrate utilization rates of the culture and has been proposed as a valuable parameter for monitoring and controlling cell cultures [14, 181, 182].”
BackgroundRodrigues, L. M., VIEIRA, L., CARDOSO, J., & de Menezes, J. C. (2008) · Talanta · doi:10.1016/j.talanta.2008.01.048 · Cited by 34 · cited 1×
“Filtering [190], centering, normalization, standardization, deviation [191], wavelength selection [192, 193], weighing, and scaling are common preprocessing methods for multivariate data [6, 194].”
MethodRehbock, C., Beutel, S., Brückerhoff, T., Hitzmann, B., Riechers, D., Rudolph, G., Stahl, F., Scheper, T. H., & Friehs, K. (2008) · Chemie Ingenieur Technik · doi:10.1002/cite.200700164 · Cited by 34
Self-citationWiedemann, P., Guez, J., Wiegemann, H. B., Egner, F., Quintana, J. C., Asanza-Maldonado, D., Filipaki, M., Wilkesman, J., Schwiebert, C., Cassar, J., et al. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23252 · Cited by 33
Thermal Biosensors in Biotechnology
Lammers, F., & Scheper, T. H. (1999) · Advances in biochemical engineering, biotechnology · doi:10.1007/3-540-49811-7_2 · Cited by 33
Self-citationDetermination of Cell Concentration and Characterization of Cells
Reardon, K. F., & Scheper, T. H. (1991) · Biotechnology · doi:10.1002/9783527620852.ch6 · Cited by 33
Self-citationOgbomo, I., Kittsteiner-Eberle, R., Englbrecht, U., Prinzing, U., Danzer, J., & Schmidt, H. (1991) · Analytica Chimica Acta · doi:10.1016/0003-2670(91)87016-z · Cited by 30 · cited 1×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodpH prediction and control in bioprocesses using mid‐infrared spectroscopy
Schenk, J., Marison, I. W., & von Stockar, U. (2008) · Biotechnology and Bioengineering · doi:10.1002/bit.21719 · Cited by 29
Yuksel, M., Akin, M., Geyik, C., Demirkol, D. O., Özdemir, Ç., Bluma, A., Höpfner, T., Beutel, S., Tımur, S., & Scheper, T. H. (2010) · Biotechnology Progress · doi:10.1002/btpr.544 · Cited by 29 · cited 4×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodSelf-citationFour-channel enzyme thermistor system for process monitoring and control in biotechnology
Hundeck, H. G., Sauerbrei, A., Hübner, U., Scheper, T. V. O., Schügerl, K., Koch, R., & Antranikian, G. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)80539-5 · Cited by 28
Self-citationSivaprakasam, S., Schuler, M. M., Hama, A., Hughes, K.-M., & Marison, I. W. (2011) · Journal of Thermal Analysis and Calorimetry · doi:10.1007/s10973-010-1259-x · Cited by 28 · cited 2×
“Thus, simple adoption to different process types and procedures is limited [165].”
BackgroundGeneral sampling system for sterile monitoring of biological processes
Håkanson, H., Nilsson, M., & Mattìasson, B. (1991) · Analytica Chimica Acta · doi:10.1016/0003-2670(91)87008-u · Cited by 27 · cited 1×
“present a general sampling system based on the use of a coaxial catheter, enabling the direct addition of metabolism inhibitor solutions to fermentation samples [33].”
BackgroundKsar, F., Sharma, G. K., Audonnet, F., Beaunier, P., & Remita, H. (2011) · Nanotechnology · Cited by 27
Ödman, P., Johansen, C. L., Lisbeth Olsson, A., Gernaey, K. V., & Lantz, A. E. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-009-2412-y · Cited by 26 · cited 1×
“This type of soft sensor uses chemometric techniques such as PLS, PCA, and NNs to describe the internal relationships between measured process data and various process variables [224,226,227].”
MethodBioanalysis and Biosensors for Bioprocess Monitoring
Sonnleitner, B. (2000) · Advances in biochemical engineering, biotechnology · doi:10.1007/3-540-48773-5 · Cited by 26
Optimal feeding strategies by adaptive mesh selection for fed-batch bioprocesses
Waldraff, W., King, R., & Gilles, E. D. (1997) · Bioprocess Engineering · doi:10.1007/s004490050378 · Cited by 24
Robust on-line sampling and analysis during long-term perfusion cultivation of mammalian cells
Chong, L., Saghafi, M., Knappe, C., Steigmiller, S., Matanguihan, C., & Goudar, C. T. (2013) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2013.03.008 · Cited by 24 · cited 1×
“There are also automated systems [21, 22] that use multivalve systems to flush tubing with cleaning solution and hot steam for sterilization after each sample-removal step [23].”
BackgroundMonitoring glutamine in animal cell cultures using a chemiluminescence fiber optic biosensor
Cattaneo, M. V., & Luong, J. H. T. (1993) · Biotechnology and Bioengineering · doi:10.1002/bit.260410609 · Cited by 24 · cited 2×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
MethodAptamer-Modified Nanoparticles as Biosensors
Lönne, M., Zhu, G., Stahl, F., & Walter, J. (2013) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2013_231 · Cited by 23
UV‐Visible Spectroscopy for On‐Line Analysis
Liauw, M., Baylor, L. C., & O’Rourke, P. E. (2010) · Wiley eBooks · doi:10.1002/9780470689592.ch4 · Cited by 22 · cited 1×
“However, UV/Vis spectroscopy does not currently play a major role for bioprocess monitoring [126].”
BackgroundBiotechnological applications of fiber-optic sensing: multiple uses of a fiber-optic fluorimeter
Anders, K.-D., Wehnert, G., Thordsen, O., Scheper, T. V. O., Rehr, B., & Sahm, H. (1993) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(93)85279-j · Cited by 22
Self-citationL-Glutamine Enzyme Electrode for On-Line Mammalian Cell Culture Process Control
Romette, J. L., & Cooney, C. L. (1987) · Analytical Letters · doi:10.1080/00032718708064592 · Cited by 22 · cited 2×
“Electrochemical Amperometric, platinum electrode Glucose, glutamine, glutamate [67] Amperometric, ferrocene electrode Glucose [68] Amperometric, oxygen electrode Glucose [69, 70] Ethanol [70, 71] Glutamine [72] Mono-, disaccharides, lactate, amino acids [73] Total sugars [74] Optical Fiber-optic-based oxygen sensor Gl…”
Method
Research works printed but not linked: 12
- R. W. Kessler 2006 Wiley‐VCH Weinheim
- Shuk P., 2010, Process zirconia oxygen analyzer‐state of art. tm‐Technisches Messen Plattform für Methoden, Systeme und Anwendungen der Messtechnik., 77, 19
- Pohlscheidt M., 2009, Bioprocess and Fermentation Monitoring, in Encyclopedia of Industrial Biotechnology
- Ruzicka J., 1988, Chemical Analysis
- Ulber R., 2000, Academic Press, Enyclopedia of Microbiology, 567
- Glindkamp A., 2009, Sensors in disposable bioreactors status and trends, Adv. Biochem. Eng. Biotechnol., 115, 145
- Henriques J. G., 2010, Optical Sensor Systems in Biotechnology, 29
- Card C., 2008, Near‐infrared spectroscopy for rapid, simultaneous monitoring, BioProcess Int., 6, 58
- Moretto J., 2011, Process Raman spectroscopy for in‐line CHO cell culture monitoring, Am. Pharmaceut. Rev., 14, 18
- Lottspeich F., 2006, Bioanalytik
- Logan D. W., 2011, BMC Proc, P57
- Shaw A. D., 1999, Advances in Biochemical Engineering and Biotechnology, 83
Cited by
Paper Electrode-Based Flexible Pressure Sensor for Point-of-Care Immunoassay with Digital Multimeter
Yu, Z., Tang, Y., Cai, G., Ren, R., & Tang, D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04635 · Cited by 341
Digital Twins in Pharmaceutical and Biopharmaceutical Manufacturing: A Literature Review
Chen, Y., Yang, O., Sampat, C., Bhalode, P., Ramachandran, R., & Ierapetritou, M. (2020) · Processes · doi:10.3390/pr8091088 · Cited by 278
“In the gas phase, the commonly used sensing system consists of semiconducting, electrochemical, and paramagnetic sensors, which can be applied to oxygen and carbon dioxide measurements [185,186].”
BackgroundMethodClaßen, J., Aupert, F., Reardon, K. F., Solle, D., & Scheper, T. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-0068-x · Cited by 176
“It includes a gas (aeration), a liquid (growth medium), and a solid phase (cells) [5].”
BackgroundInfluentialSelf-citationProcess Analytical Technologies – Advances in bioprocess integration and future perspectives
Gerzon, G., Sheng, Y., & Kirkitadze, M. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2021.114379 · Cited by 176
Blueprints for Biosensors: Design, Limitations, and Applications
Carpenter, A. C., Paulsen, I. T., & Williams, T. C. (2018) · Genes · doi:10.3390/genes9080375 · Cited by 183
“This involves the sampling of large scale biological processes such as beer/wine fermentations, garbage degradation, or bio-remediation [13,14].”
Background
Metadata
- Authors
- Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K.
- Affiliations
- Leibniz University Hannover (DE)
- Colorado State University (US)
- Corresponding author
- Solle, Dörte
- Venue
- Engineering in Life Sciences
- Publisher
- Wiley
- Published
- 2015-05-12
- Volume
- 15
- Issue
- 5
- Pages
- 469-488
- ISSN
- 1618-0240 (ISSN-L)
- 1618-2863
- OpenAlex
- W2085488202
- Semantic Scholar
- d24fffc6c68def0606d462a8628ed3175d254e61
- Cited by
- 224
- References
- 230
- Citations by year
- 2026: 27 · 2025: 22 · 2024: 17 · 2023: 17 · 2022: 23 · 2021: 23 · 2020: 22 · 2019: 24 · 2018: 14 · 2017: 22 · 2016: 10 · 2015: 3
- FWCI
- 15.12
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Engineering in Life Sciences (publishedVersion)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Fluid Dynamics and Mixing
- Physical Sciences › Environmental Science › Waste Management and Disposal › Water Quality Monitoring and Analysis
- Keywords
- bioprocess monitoring, real-time process analysis, oxygen sensors, CO2 sensor, biosensors, flow injection analysis, spectroscopic sensors, chemometrics, soft sensors, disposable sensors, biopharmaceutical manufacturing, continuous biomanufacturing, quality by design
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.