Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 324

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Detecting nanoparticulate silver using single-particle inductively coupled plasma–mass spectrometry

Mitrano, Denise M., Lesher, Emily K., Bednar, Anthony, Monserud, Jon, Higgins, Christopher P., Ranville, James F.·2012·Environmental Toxicology and Chemistry

Abstract

The environmental prevalence of engineered nanomaterials, particularly nanoparticulate silver (AgNP), is expected to increase substantially. The ubiquitous use of commercial products containing AgNP may result in their release to the environment, and the potential for ecological effects is unknown. Detecting engineered nanomaterials is one of the greatest challenges in quantifying their risks. Thus, it is imperative to develop techniques capable of measuring and characterizing exposures, while dealing with the innate difficulties of nanomaterial detection in environmental samples, such as low-engineered nanomaterial concentrations, aggregation, and complex matrices. Here the authors demonstrate the use of inductively coupled plasma–mass spectrometry, operated in a single-particle counting mode (SP-ICP-MS), to detect and quantify AgNP. In the present study, two AgNP products were measured by SP-ICP-MS, including one of precisely manufactured size and shape, as well as a commercial AgNP-containing health food product. Serial dilutions, filtration, and acidification were applied to confirm that the method detected particles. Differentiation of dissolved and particulate silver (Ag) is a feature of the technique. Analysis of two wastewater samples demonstrated the applicability of SP-ICP-MS at nanograms per liter Ag concentrations. In this pilot study, AgNP was found at 100 to 200 ng/L in the presence of 50 to 500 ng/L dissolved Ag. The method provides the analytical capability to monitor Ag and other metal and metal oxide nanoparticles in fate, transport, stability, and toxicity studies using a commonly available laboratory instrument. Rapid throughput and element specificity are additional benefits of SP-ICP-MS as a measurement tool for metal and metal oxide engineered nanoparticles. Environ. Toxicol. Chem. 2012;31:115–121. © 2011 SETAC

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/etc.719

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Cited by

Metadata

Authors
Mitrano, D. M., Lesher, E. K., Bednar, A., Monserud, J., Higgins, C. P., & Ranville, J. F.
Venue
Environmental Toxicology and Chemistry
Published
2011-10-19
Volume
31
Issue
1
Pages
115-121
ISSN
  • 0730-7268 (ISSN-L)
  • 1552-8618
OpenAlex
W2156884607
Cited by
324
References
36
FWCI
13.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.