Functional decoupling of BOLD and gamma‐band amplitudes in human primary visual cortex
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Although functional magnetic resonance imaging is an important tool for measuring brain activity, the hemodynamic blood oxygenation level dependent (BOLD) response is only an indirect measure of neuronal activity. Converging evidence obtained from simultaneous recording of hemodynamic and electrical measures suggest that the best correlate of the BOLD response in primary visual cortex is gamma‐band oscillations (∼40 Hz). Here, we examined the coupling between BOLD and gamma‐band amplitudes measured with magntoencephalography (MEG) in human primary visual cortex in 10 participants. In Experiment A, participants were exposed to grating stimuli at two contrast levels and two spatial frequencies and in Experiment B square and sine wave stimuli at two spatial frequencies. The amplitudes of both gamma‐band oscillations and BOLD showed tuning with stimulus contrast and stimulus type; however, gamma‐band oscillations showed a 300% increase across two spatial frequencies, whereas BOLD exhibited no change. This functional decoupling demonstrates that increased amplitude of gamma‐band oscillations as measured with MEG is not sufficient to drive the subsequent BOLD response. Hum Brain Mapp, 2009. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neurophysiological investigation of the basis of the fMRI signal
Logothetis, N. K., Pauls, J., Augath, M., Trinath, T., & Oeltermann, A. (2001) · Nature · doi:10.1038/35084005 · Cited by 6,551 · cited 4×
“Invasive simultaneous recording work in animals [Logothetis et al., 2001] has demonstrated a complex origin of the BOLD response, which appears correlated not only to local field potentials but also to some extent in multiunit activity.”
BackgroundResultInfluentialThe basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Stimulus-specific neuronal oscillations in orientation columns of cat visual cortex
Gray, C. M., & Singer, W. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.5.1698 · Cited by 2,463
A three-dimensional statistical analysis for CBF activation studies in human brain
Worsley, K. J., Evans, A. C., Marrett, S., & Neelin, P. (1992) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1992.127 · Cited by 2,036
Hemodynamic Signals Correlate Tightly with Synchronized Gamma Oscillations
Niessing, J., Ebisch, B., Schmidt, K. E., Niessing, M., Singer, W., & Galuske, R. A. W. (2005) · Science · doi:10.1126/science.1110948 · Cited by 806 · cited 5×
“Fluctuations of the BOLD response to the same stimulus correlate well with corresponding fluctuations in the gamma-band response [Niessing et al., 2005].”
BackgroundResultInfluentialSignal Processing in Magnetoencephalography
Vrba, J., & Robinson, S. E. (2001) · Methods · doi:10.1006/meth.2001.1238 · Cited by 716 · cited 2×
“Details of the calculation of SAM pseudo-T source image statistics are described in detail in a number of sources [Cheyne et al., 2003; Hillebrand et al., 2005; Robinson and Vrba, 1999; Singh et al., 2003; Vrba and Robinson, 2001].”
MethodNir, Y., Fisch, L., Mukamel, R., Gelbard-Sagiv, H., Arieli, A., Fried, I., & Malach, R. (2007) · Current Biology · doi:10.1016/j.cub.2007.06.066 · Cited by 621 · cited 2×
“Similar findings have also been reported when BOLD and invasive recordings are made non-simultaneously [Kayser et al., 2004; Nir et al., 2007].”
BackgroundResultNunez, P. L., & Silberstein, R. B. (2000) · Brain Topography · doi:10.1023/a:1026683200895 · Cited by 307
Cited by
Muthukumaraswamy, S. D., Edden, R. A. E., Jones, D. K., Swettenham, J. B., & Singh, K. D. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0900728106 · Cited by 567
Self-citationScheeringa, R., Fries, P., Petersson, K.-M., Oostenveld, R., Grothe, I., Norris, D. G., Hagoort, P., & Bastiaansen, M. C. M. (2011) · Neuron · doi:10.1016/j.neuron.2010.11.044 · Cited by 446
Gamma oscillations as a biomarker for major depression: an emerging topic
Fitzgerald, P. J., & Watson, B. O. (2018) · Translational Psychiatry · doi:10.1038/s41398-018-0239-y · Cited by 366
Functional Properties of Human Primary Motor Cortex Gamma Oscillations
Muthukumaraswamy, S. D. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00607.2010 · Cited by 300
Self-citationYuan, H., Liu, T., Szarkowski, R., Rios, C., Ashe, J., & He, B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.028 · Cited by 274
Jerbi, K., Ossandón, T., Hamamé, C. M., Senova, S., Dalal, S. S., Jung, J., Minotti, L., Bertrand, O., Berthoz, A., Kahane, P., et al. (2009) · Human Brain Mapping · doi:10.1002/hbm.20750 · Cited by 272
The relationship between oscillatory EEG activity and the laminar-specific BOLD signal
Scheeringa, R., Koopmans, P. J., van Mourik, T., Jensen, O., & Norris, D. G. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522577113 · Cited by 162
Brain imaging of the self-conceptual, anatomical and methodological issues
Northoff, G., Qin, P., & Feinberg, T. E. (2011) · Consciousness and Cognition · doi:10.1016/j.concog.2010.09.011 · Cited by 135
“Muthukumaraswamy and Singh (2009) for instance demonstrated the association of GABA with NBR in visual cortex (Muthukumaraswamy & Singh, 2009).”
Ketamine amplifies induced gamma frequency oscillations in the human cerebral cortex
Shaw, A. D., Saxena, N., E. Jackson, L., Hall, J. E., Singh, K. D., & Muthukumaraswamy, S. D. (2015) · European Neuropsychopharmacology · doi:10.1016/j.euroneuro.2015.04.012 · Cited by 122
Self-citationEstimating the transfer function from neuronal activity to BOLD using simultaneous EEG-fMRI
Rosa, M. J., Kilner, J., Blankenburg, F., Josephs, O., & Penny, W. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.011 · Cited by 105
Metadata
- Authors
- Muthukumaraswamy, S. D., & Singh, K. D.
- Venue
- Human Brain Mapping
- Publisher
- Wiley
- Published
- 2008-08-26
- Volume
- 30
- Issue
- 7
- Pages
- 2000-2007
- ISSN
- 1065-9471 (ISSN-L)
- 1097-0193
- OpenAlex
- W2096806648
- Cited by
- 60
- References
- 8
- FWCI
- 4.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.