CoChat

Free water elimination improves test–retest reproducibility of diffusion tensor imaging indices in the brain: A longitudinal multisite study of healthy elderly subjects

Open access
Albi, Angela, Pasternak, Ofer, Minati, Ludovico, Marizzoni, Moira, Bartrés‐Faz, David, Bargalló, Núria, Bosch, Beatriz, Rossini, Paolo Maria, Marra, Camillo, Müller, Bernhard, Fiedler, Ute, Wiltfang, Jens, Roccatagliata, Luca, Picco, Agnese, Nobili, Flavio Mariano, Blin, Oliver, Sein, Julien, Ranjeva, Jean‐Philippe, Didic, Mira, Bombois, Stephanie, Lopes, Renaud, Bordet, Régis, Gros‐Dagnac, Hélène, Payoux, Pierre, Zoccatelli, Giada, Alessandrini, Franco, Beltramello, Alberto, Ferretti, Antonio, Caulo, Massimo, Aiello, Marco, Cavaliere, Carlo, Soricelli, Andrea, Parnetti, Lucilla, Tarducci, Roberto, Floridi, Piero, Tsolaki, Magda, Constantinidis, Manos, Drevelegas, Antonios, Frisoni, Giovanni, Jovicich, Jorge, The PharmaCog Consortium · 2017 · Human Brain Mapping
Cited by 90

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

Free water elimination (FWE) in brain diffusion MRI has been shown to improve tissue specificity in human white matter characterization both in health and in disease. Relative to the classical diffusion tensor imaging (DTI) model, FWE is also expected to increase sensitivity to microstructural changes in longitudinal studies. However, it is not clear if these two models differ in their test–retest reproducibility. This study compares a bi‐tensor model for FWE with DTI by extending a previous longitudinal‐reproducibility 3T multisite study (10 sites, 7 different scanner models) of 50 healthy elderly participants (55–80 years old) scanned in two sessions at least 1 week apart. We computed the reproducibility of commonly used DTI metrics (FA: fractional anisotropy, MD: mean diffusivity, RD: radial diffusivity, and AXD: axial diffusivity), derived either using a DTI model or a FWE model. The DTI metrics were evaluated over 48 white‐matter regions of the JHU‐ICBM‐DTI‐81 white‐matter labels atlas, and reproducibility errors were assessed. We found that relative to the DTI model, FWE significantly reduced reproducibility errors in most areas tested. In particular, for the FA and MD metrics, there was an average reduction of approximately 1% in the reproducibility error. The reproducibility scores did not significantly differ across sites. This study shows that FWE improves sensitivity and is thus promising for clinical applications, with the potential to identify more subtle changes. The increased reproducibility allows for smaller sample size or shorter trials in studies evaluating biomarkers of disease progression or treatment effects.Hum Brain Mapp 38:12–26, 2017. ©2016 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/hbm.23350

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 90

Metadata

Authors
Albi, A., Pasternak, O., Minati, L., Marizzoni, M., Bartrés‐Faz, D., Bargalló, N., Bosch, B., Rossini, P. M., Marra, C., Müller, B., Fiedler, U., Wiltfang, J., Roccatagliata, L., Picco, A., Nobili, F. M., Blin, O., Sein, J., Ranjeva, J., Didic, M., Bombois, S., Lopes, R., Bordet, R., Gros‐Dagnac, H., Payoux, P., Zoccatelli, G., Alessandrini, F., Beltramello, A., Ferretti, A., Caulo, M., Aiello, M., Cavaliere, C., Soricelli, A., Parnetti, L., Tarducci, R., Floridi, P., Tsolaki, M., Constantinidis, M., Drevelegas, A., Frisoni, G., Jovicich, J., & The PharmaCog Consortium
Venue
Human Brain Mapping
Publisher
Wiley
Published
2016-08-13
Volume
38
Issue
1
Pages
12-26
ISSN
  • 1065-9471 (ISSN-L)
  • 1097-0193
OpenAlex
W2508881670
Cited by
90
References
22
FWCI
5.26
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Free water elimination improves test–retest reproducibility of diffusion tensor imaging indices in the brain: A longitudinal multisite study of healthy elderly subjects. https://app.cochat.ai/papers/10.1002/hbm.23350
The paper
Albi, A., Pasternak, O., Minati, L., Marizzoni, M., Bartrés‐Faz, D., Bargalló, N., Bosch, B., Rossini, P. M., Marra, C., Müller, B., Fiedler, U., Wiltfang, J., Roccatagliata, L., Picco, A., Nobili, F. M., Blin, O., Sein, J., Ranjeva, J., Didic, M., . . . The PharmaCog Consortium. (2017). Free water elimination improves test–retest reproducibility of diffusion tensor imaging indices in the brain: A longitudinal multisite study of healthy elderly subjects. Human Brain Mapping. https://doi.org/10.1002/hbm.23350

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.