CoChat

Automated quality assessment of structural magnetic resonance images in children: Comparison with visual inspection and surface‐based reconstruction

Open access
White, Tonya, Jansen, Philip R., Muetzel, Ryan L., Sudre, Gustavo, El Marroun, Hanan, Tiemeier, Henning, Qiu, Anqi, Shaw, Philip, Michael, Andrew M., Verhulst, Frank C. · 2018 · Human Brain Mapping
Cited by 62

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Motion‐related artifacts are one of the major challenges associated with pediatric neuroimaging. Recent studies have shown a relationship between visual quality ratings of T 1 images and cortical reconstruction measures. Automated algorithms offer more precision in quantifying movement‐related artifacts compared to visual inspection. Thus, the goal of this study was to test three different automated quality assessment algorithms for structural MRI scans. The three algorithms included a Fourier‐, integral‐, and a gradient‐based approach which were run on raw T 1‐weighted imaging data collected from four different scanners. The four cohorts included a total of 6,662 MRI scans from two waves of the Generation R Study, the NIH NHGRI Study, and the GUSTO Study. Using receiver operating characteristics with visually inspected quality ratings of the T 1 images, the area under the curve (AUC) for the gradient algorithm, which performed better than either the integral or Fourier approaches, was 0.95, 0.88, and 0.82 for the Generation R, NHGRI, and GUSTO studies, respectively. For scans of poor initial quality, repeating the scan often resulted in a better quality second image. Finally, we found that even minor differences in automated quality measurements were associated with FreeSurfer derived measures of cortical thickness and surface area, even in scans that were rated as good quality. Our findings suggest that the inclusion of automated quality assessment measures can augment visual inspection and may find use as a covariate in analyses or to identify thresholds to exclude poor quality data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/hbm.23911

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 62

Metadata

Authors
White, T., Jansen, P. R., Muetzel, R. L., Sudre, G., El Marroun, H., Tiemeier, H., Qiu, A., Shaw, P., Michael, A. M., & Verhulst, F. C.
Venue
Human Brain Mapping
Publisher
Wiley
Published
2017-12-05
Volume
39
Issue
3
Pages
1218-1231
ISSN
  • 1065-9471 (ISSN-L)
  • 1097-0193
OpenAlex
W2771414833
Cited by
62
References
8
FWCI
4.54
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated quality assessment of structural magnetic resonance images in children: Comparison with visual inspection and surface‐based reconstruction. https://app.cochat.ai/papers/10.1002/hbm.23911
The paper
White, T., Jansen, P. R., Muetzel, R. L., Sudre, G., El Marroun, H., Tiemeier, H., Qiu, A., Shaw, P., Michael, A. M., & Verhulst, F. C. (2018). Automated quality assessment of structural magnetic resonance images in children: Comparison with visual inspection and surface‐based reconstruction. Human Brain Mapping. https://doi.org/10.1002/hbm.23911

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.