The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Near‐infrared Raman spectroscopy for optical diagnosis of lung cancer
Abstract
Raman spectroscopy is a vibrational spectroscopic technique that can be used to optically probe the molecular changes associated with diseased tissues. The objective of our study was to explore near‐infrared (NIR) Raman spectroscopy for distinguishing tumor from normal bronchial tissue. Bronchial tissue specimens (12 normal, 10 squamous cell carcinoma (SCC) and 6 adenocarcinoma) were obtained from 10 patients with known or suspected malignancies of the lung. A rapid‐acquisition dispersive‐type NIR Raman spectroscopy system was used for tissue Raman studies at 785 nm excitation. High‐quality Raman spectra in the 700–1,800 cm–1 range from human bronchial tissues in vitro could be obtained within 5 sec. Raman spectra differed significantly between normal and malignant tumor tissue, with tumors showing higher percentage signals for nucleic acid, tryptophan and phenylalanine and lower percentage signals for phospholipids, proline and valine, compared to normal tissue. Raman spectral shape differences between normal and tumor tissue were also observed particularly in the spectral ranges of 1,000–1,100, 1,200–1,400 and 1,500–1,700 cm–1, which contain signals related to protein and lipid conformations and nucleic acid's CH stretching modes. The ratio of Raman intensities at 1,445 to 1,655 cm–1 provided good differentiation between normal and malignant bronchial tissue (p < 0.0001). The results of this exploratory study indicate that NIR Raman spectroscopy provides significant potential for the noninvasive diagnosis of lung cancers in vivo based on the optic evaluation of biomolecules. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical Methods for Rates and Proportions, 2nd ed
GROVE, W. A. (1981) · American Journal of Psychiatry · doi:10.1176/ajp.138.12.1644-a · Cited by 3,748
Greenlee, R. T., Hill-Harmon, M. B., Murray, T., & Thun, M. (2001) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.51.1.15 · Cited by 3,288
Bloom, W., & Fawcett, D. W. (1962) · Cited by 2,206
Statistical Methods for Rates and Proportions.
Plewis, I., & Fleiss, J. L. (1982) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2982107 · Cited by 1,731
Characteristic Raman frequencies of organic compounds
Dollish, F. R., Fateley, W. G., & Bentley, F. F. (1974) · Cited by 839
Characteristic Raman frequencies of organic compounds
W.J.O.-T (1974) · Journal of Molecular Structure · doi:10.1016/0022-2860(74)87027-4 · Cited by 733
Localization of Bronchial Intraepithelial Neoplastic Lesions by Fluorescence Bronchoscopy
Lam, S., Kennedy, T., Unger, M., Miller, Y. E., Gelmont, D., Rusch, V., Gipe, B., Howard, D., LeRiche, J. C., Coldman, A., et al. (1998) · Chest · doi:10.1378/chest.113.3.696 · Cited by 571
Self-citationStructural studies of protein–nucleic acid interaction: the sources of sequence-specific binding
Steitz, T. A. (1990) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500005552 · Cited by 505
Raman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475
Spectroscopy of biological systems
Johnson, P. (1987) · Endeavour · doi:10.1016/0160-9327(87)90264-x · Cited by 412
Raman Spectroscopy of Normal and Diseased Human Breast Tissues
Frank, C. J., McCreery, R. L., & Redd, D. C. B. (1995) · Analytical Chemistry · doi:10.1021/ac00101a001 · Cited by 400
Non-Invasive Raman Spectroscopic Detection of Carotenoids in Human Skin
Hata, T. R., Scholz, T. A., Pershing, L. K., Ermakov, I. V., McClane, R. W., Khachik, F., & Gellermann, W. (2000) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2000.00060.x · Cited by 343
Shim, M. G., Wong Kee Song, L.-M., Marcon, N. E., & Wilson, B. C. (2000) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2000)0720146ivnirs2.0.co2 · Cited by 296
Near‐Infrared Raman Spectroscopy for In Vitro Detection of Cervical Precancers
Mahadevan‐Jansen, A., Mitchell, M. F., Ramanujamf, N., Malpica, A., Thomsen, S., Utzinger, U., & Richards‐Kortumt, R. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb03262.x · Cited by 282
Near-Infrared Raman Spectroscopy for in vivo Detection of Cervical Precancers
Utzinger, U., Heintzelman, D. L., Mahadevan-Jansen, A., Malpica, A., Follen, M., & Richards-Kortum, R. (2001) · Applied Spectroscopy · doi:10.1366/0003702011953018 · Cited by 251
Raman Spectroscopy for Early Detection of Laryngeal Malignancy: Preliminary Results
Stone, N., Stavroulaki, P., Kendall, C., Birchall, M., & Barr, H. (2000) · The Laryngoscope · doi:10.1097/00005537-200010000-00037 · Cited by 228
In vivo Fluorescence Spectroscopy of Nonmelanoma Skin Cancer¶
Brancaleon, L., Durkin, A. J., Tu, J. H., Menaker, G. M., Fallon, J. D., & Kollias, N. (2001) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2001)0730178ivfson2.0.co2 · Cited by 200
Rapid near-infrared Raman spectroscopy system for real-time in vivo skin measurements
Huang, Z., Zeng, H., Hamzavi, I., McLean, D. I., & Lui, H. (2001) · Optics Letters · doi:10.1364/ol.26.001782 · Cited by 197
Self-citationIn Vivo Detection of Dysplastic Tissue by Raman Spectroscopy
Bakker Schut, T. C., Witjes, M. J. H., Sterenborg, H. J. C. M., Speelman, O. C., Roodenburg, J. L. N., Marple, E. T., Bruining, H. A., & Puppels, G. J. (2000) · Analytical Chemistry · doi:10.1021/ac000780u · Cited by 194
Development of a Fiber Optic Probe to Measure NIR Raman Spectra of Cervical Tissue In Vivo
Mahadevan‐Jansen, A., Mitchell, M. F., Ramanujam, N., Utzinger, U., & Richards‐Kortum, R. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb09703.x · Cited by 192
Lau, D. P., Huang, Z., Lui, H., Man, C. S., Berean, K., Morrison, M. D., & Zeng, H. (2003) · Lasers in Surgery and Medicine · doi:10.1002/lsm.10084 · Cited by 185
Self-citationRaman Spectroscopy and Fluorescence Photon Migration for Breast Cancer Diagnosis and Imaging
Manoharan, R., Shafer, K., Perelman, L., Wu, J., Chen, K., Deinum, G., Fitzmaurice, M., Myles, J., Crowe, J., Dasarl, R. R., et al. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb05160.x · Cited by 170
Development of a Fiber Optic Probe to Measure NIR Raman Spectra of Cervical Tissue In Vivo
Mahadevan-Jansen, A., Mitchell, M. F., Ramanujam, N., Utzinger, U., & Richards-Kortum, R. (1998) · Photochemistry and Photobiology · doi:10.1562/0031-8655(1998)068<0427:doafop>2.3.co;2 · Cited by 168
Koyama, Y., Takatsuka, I., Nakata, M., et al. (1988) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1250190107 · Cited by 155
Huang, Z., McWilliams, A. M., Lam, S. C., English, J. C., McLean, D. I., Lui, H., & Zeng, H. (2003) · International Journal of Oncology · doi:10.3892/ijo.23.3.649 · Cited by 128
Self-citationShim, M. G., & Wilson, B. C. (1996) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1996.tb05671.x · Cited by 110
Human breast tissues studied by IR Fourier-transform Raman spectroscopy
Liu, C. H., Alfano, R. R., Sha, W. L., Zhu, H., Akins, D. L., Cleary, J., Prudente, R., & EJ, C. (1991) · Conference on Lasers and Electro-Optics · Cited by 95
Zellweger, M., Grosjean, P., Goujon, D., Monnier, P., van den Bergh, H., & Wagnières, G. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1332774 · Cited by 81
Kaminaka, S., Yamazaki, H., Ito, T., Kohda, E., & Hamaguchi, H. (2001) · Journal of Raman Spectroscopy · doi:10.1002/jrs.680 · Cited by 73
McMillan, D. C., Talwar, D. K., Sattar, N. A., UNDERWOOD, M., O’Reilly, D. S. J., & McArdle, C. S. (2002) · Clinical Nutrition · doi:10.1054/clnu.2001.0527 · Cited by 57
Application of near‐infrared‐Fourier transform Raman spectroscopy in medical research
Keller, S., Schräder, B., Hoffmann, A., Schräder, W., Metz, K. A., Rehlaender, A., Pahnke, J.-M., Ruwe, M., & Budach, W. (1994) · Journal of Raman Spectroscopy · doi:10.1002/jrs.1250250729 · Cited by 55
Schut, T. C. B., Puppels, G. J., Kraan, Y. M., Greve, J., van der Maas, L. L. J., & Figdor, C. G. (1997) · International Journal of Cancer · doi:10.1002/(sici)1097-0215(19970220)74:1<20::aid-ijc4>3.0.co;2-2 · Cited by 53
Cited by
Raman Spectroscopy of Biological Tissues
Movasaghi, Z., Rehman, S., & Rehman, I. U. (2007) · Applied Spectroscopy Reviews · doi:10.1080/05704920701551530 · Cited by 2,518
Histopathological Image Analysis: A Review
Gurcan, M. N., Boucheron, L. E., Can, A., Madabhushi, A., Rajpoot, N. M., & Yener, B. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2034865 · Cited by 2,052
Fourier Transform Infrared (FTIR) Spectroscopy of Biological Tissues
Movasaghi, Z., Rehman, S., & ur Rehman, D. I. (2008) · Applied Spectroscopy Reviews · doi:10.1080/05704920701829043 · Cited by 1,916
Using Raman spectroscopy to characterize biological materials
Butler, H. J., Ashton, L., Bird, B., Cinque, G., Curtis, K., Dorney, J., Esmonde-White, K., Fullwood, N. J., Gardner, B., Martin-Hirsch, P. L., et al. (2016) · Nature Protocols · doi:10.1038/nprot.2016.036 · Cited by 1,309
Coherent Anti-Stokes Raman Scattering Microscopy: Chemical Imaging for Biology and Medicine
Evans, C. L., & Xie, X. S. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112754 · Cited by 1,150
Metadata
- Authors
- Huang, Z., McWilliams, A., Lui, H., McLean, D. I., Lam, S., & Zeng, H.
- Venue
- International Journal of Cancer
- Publisher
- Wiley
- Published
- 2003-09-18
- Volume
- 107
- Issue
- 6
- Pages
- 1047-1052
- ISSN
- 0020-7136 (ISSN-L)
- 1097-0215
- OpenAlex
- W2097358067
- Cited by
- 821
- References
- 32
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.