In vivo validation of the bold mechanism: A review of signal changes in gradient echo functional MRI in the presence of flow
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Brain functional magnetic resonance imaging (FMRI) is possible because of local changes in blood flow and oxygenation levels. Understanding the role of each mechanism is important for interpreting FMRI results as well as for the design of the experiment itself. In this review, we address the role of flow and blood oxygen level dependence (BOLD) and how they can be used in conjunction with each other to enhance the BOLD effect. We also discuss the role of intra/extravascular signal changes in the presence of a vessel for the imaging situation and show how the ratio of these two contributions is likely to change as the blood volume fraction changes. Using the BOLD model itself, along with 3‐D phase imaging, we show that blood oxygenation level in veins in vivo is Y = 0.544 ± 0.029 as measured in 14 vessels in five subjects. Finally, we comment on the use of phase images themselves as a means to discriminate tissues with different levels of blood such as gray matter, white matter, and cerebrospinal fluid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Ogawa, S., Menon, R. S., Tank, D. W., Kim, S. G., Merkle, H., Ellermann, J. M., & Ugurbil, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81441-3 · Cited by 1,772
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Lai, S., Hopkins, A. L., Haacke, E. M., Li, D., Wasserman, B. A., Buckley, P., Friedman, L., Meltzer, H., Hedera, P., & Friedland, R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300318 · Cited by 390
Self-citation
Cited by
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
“This has already been demonstrated for GM/WM contrast (10), small veins in the brain (11), and more recently in venous blood vessels in the peripheral vasculature (8).”
BackgroundSelf-citationSusceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
Self-citationImaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Self-citationThe neural basis of the blood–oxygen–level–dependent functional magnetic resonance imaging signal
Logothetis, N. K. (2002) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.2002.1114 · Cited by 958
Schweser, F., Deistung, A., Lehr, B. W., & Reichenbach, J. R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.070 · Cited by 710
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Self-citationvan Zijl, P. C. M., Eleff, S. M., Ulatowski, J. A., Oja, J. M. E., Uluǧ, A. M., Traystman, R. J., & Kauppinen, R. A. (1998) · Nature Medicine · doi:10.1038/nm0298-159 · Cited by 501
Clinical applications of neuroimaging with susceptibility‐weighted imaging
Sehgal, V., Delproposto, Z., Haacke, E. M., Tong, K. A., Wycliffe, N., Kido, D. K., Xu, Y., Neelavalli, J., Haddar, D., & Reichenbach, J. R. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20404 · Cited by 427
Self-citationDuong, T. Q., Yacoub, E., Adriany, G., Hu, X., Uǧurbil, K., & Kim, S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10472 · Cited by 360
Characterizing iron deposition in multiple sclerosis lesions using susceptibility weighted imaging
Haacke, E. M., Makki, M., Ge, Y., Maheshwari, M., Sehgal, V., Hu, J., Selvan, M., Wu, Z., Latif, Z., Xuan, Y., et al. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21676 · Cited by 329
“Phase images are a direct measure of the sources of local susceptibility changes (34,36,37).”
BackgroundSelf-citationTheory and application of static field inhomogeneity effects in gradient‐echo imaging
Reichenbach, J. R., Venkatesan, R., Yablonskiy, D. A., Thompson, M. R., Lai, S., & Haacke, E. M. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070203 · Cited by 285
Self-citationBiophysical mechanisms of phase contrast in gradient echo MRI
He, X., & Yablonskiy, D. A. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904899106 · Cited by 272
Self-citationIdentification of calcification with MRI using susceptibility‐weighted imaging: A case study
Wu, Z., Mittal, S., Kish, K., Yu, Y., Hu, J., & Haacke, E. M. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21617 · Cited by 260
Self-citationHigh‐resolution BOLD venographic imaging: a window into brain function
Reichenbach, J. R., & Haacke, E. M. (2001) · NMR in Biomedicine · doi:10.1002/nbm.722 · Cited by 248
Self-citationSusceptibility-weighted Imaging: Technical Essentials and Clinical Neurologic Applications
Haller, S., Haacke, E. M., Thurnher, M. M., & Barkhof, F. (2021) · Radiology · doi:10.1148/radiol.2021203071 · Cited by 244
“Basic Underpinnings of SWI Postprocessing The concept of filtering the phase to highlight paramagnetic structures was a key advancement in developing SWI (8,9) and eventually in the use of the nomenclature SWI (1).”
MethodSelf-citationOgg, R. J., Langston, J. W., Haacke, E. M., Steen, R. G., & Taylor, J. S. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00017-x · Cited by 205
Self-citationHigh-Resolution MR Venography at 3.0 Tesla
Reichenbach, J. R., Barth, M., Haacke, E. M., Klarhöfer, M., Kaiser, W. A., & Moser, E. (2000) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200011000-00023 · Cited by 199
Self-citationDeistung, A., Rauscher, A., Sedlacik, J., Stadler, J., Witoszynskyj, S., & Reichenbach, J. R. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21754 · Cited by 169
Metadata
- Authors
- Haacke, E. M., Lai, S., Yablonskiy, D. A., & Lin, W.
- Venue
- International Journal of Imaging Systems and Technology
- Publisher
- Wiley
- Published
- 1995-06
- Volume
- 6
- Issue
- 2-3
- Pages
- 153-163
- ISSN
- 0899-9457 (ISSN-L)
- 1098-1098
- OpenAlex
- W2138321506
- Cited by
- 109
- References
- 4
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.