The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Scanning fiber endoscopy with highly flexible, 1 mm catheterscopes for wide‐field, full‐color imaging
Open accessAbstract
In modern endoscopy, wide field of view and full color are considered necessary for navigating inside the body, inspecting tissue for disease and guiding interventions such as biopsy or surgery. Current flexible endoscope technologies suffer from reduced resolution when device diameter shrinks. Endoscopic procedures today, using coherent fiber‐bundle technology on the scale of 1 mm, are performed with such poor image quality that the clinician's vision meets the criteria for legal blindness. Here, we review a new and versatile scanning fiber‐imaging technology and describe its implementation for ultrathin and flexible endoscopy. This scanning fiber endoscope (SFE) or catheterscope enables high‐quality, laser‐based, video imaging for ultrathin clinical applications, while also providing new options for in vivo biological research of subsurface tissue and high resolution fluorescence imaging. (© 2010 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
Self-citationHandbook of Biological Confocal Microscopy
(1995) · Springer eBooks · doi:10.1007/978-1-4757-5348-6 · Cited by 1,848
Engelbrecht, R. S., Hsu, H., Amplifiers, P., & Kotzebue, K. L. (1959) · Cited by 1,417
Gold nanocages covered by smart polymers for controlled release with near-infrared light
Yavuz, M. S., Cheng, Y., Chen, J., Cobley, C. M., Zhang, Q., Rycenga, M., Xie, J., Kim, C., Song, K. H., Schwartz, A. G., et al. (2009) · Nature Materials · doi:10.1038/nmat2564 · Cited by 1,405
Confocal laser endoscopy for diagnosing intraepithelial neoplasias and colorectal cancer in vivo
Kiesslich, R., Burg, J., Vieth, M., Gnaendiger, J., Enders, M., Delaney, P., Polglase, A., McLaren, W., Janell, D., Thomas, S., et al. (2004) · Gastroenterology · doi:10.1053/j.gastro.2004.06.050 · Cited by 843
Serial time-encoded amplified imaging for real-time observation of fast dynamic phenomena
Goda, K., Tsia, K. K., & Jalali, B. (2009) · Nature · doi:10.1038/nature07980 · Cited by 763
Photon Upmanship: Why Multiphoton Imaging Is More than a Gimmick
Denk, W., & Svoboda, K. (1997) · Neuron · doi:10.1016/s0896-6273(00)81237-4 · Cited by 676
A Miniature Head-Mounted Two-Photon Microscope
Helmchen, F., Fee, M. S., Tank, D. W., & Denk, W. (2001) · Neuron · doi:10.1016/s0896-6273(01)00421-4 · Cited by 622
Self-citationHandbook of Optical Biomedical Diagnostics
Tuchin, V. V. (2002) · Medical Entomology and Zoology · Cited by 501
Comprehensive volumetric optical microscopy in vivo
Yun, S. H., Tearney, G. J., Vakoc, B. J., Shishkov, M., Oh, W. Y., Desjardins, A. E., Suter, M. J., Chan, R. C., Evans, J. A., Jang, I.-K., et al. (2006) · Nature Medicine · doi:10.1038/nm1450 · Cited by 438
High-speed, miniaturized fluorescence microscopy in freely moving mice
Flusberg, B. A., Nimmerjahn, A., Cocker, E. D., Mukamel, E. A., Barretto, R. P. J., Ko, T. H., Burns, L. D., Jung, J. C., & Schnitzer, M. J. (2008) · Nature Methods · doi:10.1038/nmeth.1256 · Cited by 385
The utility of a novel narrow band imaging endoscopy system in patients with Barrett's esophagus
Sharma, P., Bansal, A., Mathur, S., Wani, S., Cherian, R., McGregor, D., Higbee, A., Hall, S., & Weston, A. (2006) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2005.10.044 · Cited by 364
The human eye: structure and function
(2000) · Choice Reviews Online · doi:10.5860/choice.37-3340 · Cited by 294
Ultra-compact fiber-optic two-photon microscope for functional fluorescence imaging in vivo
Engelbrecht, C. J., Johnston, R. S., Seibel, E. J., & Helmchen, F. (2008) · Optics Express · doi:10.1364/oe.16.005556 · Cited by 279
Self-citationAdvances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Wei Ho, E. T., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 278
Porphyrin‐related photosensitizers for cancer imaging and therapeutic applications
BERG, K., SELBO, P. K., WEYERGANG, A., DIETZE, A., PRASMICKAITE, L., BONSTED, A., ENGESAETER, B. Ø., ANGELL‐PETERSEN, E., WARLOE, T., FRANDSEN, N., et al. (2005) · Journal of Microscopy · doi:10.1111/j.1365-2818.2005.01471.x · Cited by 274
Jung, J. C., & Schnitzer, M. J. (2003) · Optics Letters · doi:10.1364/ol.28.000902 · Cited by 266
In vivo brain imaging using a portable 39?gram two-photon fluorescence microendoscope
Flusberg, B. A., Jung, J. C., Cocker, E. D., Anderson, E. P., & Schnitzer, M. J. (2005) · Optics Letters · doi:10.1364/ol.30.002272 · Cited by 260
Göbel, W., Kerr, J. N. D., Nimmerjahn, A., & Helmchen, F. (2004) · Optics Letters · doi:10.1364/ol.29.002521 · Cited by 259
Self-citationVisually evoked activity in cortical cells imaged in freely moving animals
Sawinski, J., Wallace, D. J., Greenberg, D. S., Grossmann, S., Denk, W., & Kerr, J. N. D. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903680106 · Cited by 233
Solid-State Circuits Conference
Edwards, W. J., MEINDL, J. D., & Harnwell, G. P. (1969) · Cited by 198
Silicon-micromachined scanning confocal optical microscope
Dickensheets, D. L., & Kino, G. S. (1998) · Journal of Microelectromechanical Systems · doi:10.1109/84.661382 · Cited by 187
CMOS image sensors: State-of-the-art
Theuwissen, A. J. P. (2008) · Solid-State Electronics · doi:10.1016/j.sse.2008.04.012 · Cited by 180
Piyawattanametha, W., Cocker, E. D., Burns, L. D., Barretto, R. P. J., Jung, J. C., Ra, H., Solgaard, O., & Schnitzer, M. J. (2009) · Optics Letters · doi:10.1364/ol.34.002309 · Cited by 180
Nonlinear optical endoscopy based on a double-clad photonic crystal fiber and a MEMS mirror
Fu, L., Jain, A., Xie, H., Cranfield, C., & Gu, M. (2006) · Optics Express · doi:10.1364/oe.14.001027 · Cited by 160
Wu, Y., Leng, Y., Xi, J., & Li, X. D. (2009) · Optics Express · doi:10.1364/oe.17.007907 · Cited by 157
Piyawattanametha, W., Barretto, R. P. J., Ko, T. H., et al. (2006) · Optics Letters · doi:10.1364/ol.31.002018 · Cited by 153
Lipson, S. G., Lipson, H., & Tannhauser, D. S. (1995) · Cambridge University Press eBooks · doi:10.1017/cbo9781139170413 · Cited by 129
Tang, S., Jung, W., McCormick, D. T., Xie, T., Su, J., Ahn, Y., Tromberg, B. J., & Chen, Z. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3127203 · Cited by 122
Göbel, W., Nimmerjahn, A., & Helmchen, F. (2004) · Optics Letters · doi:10.1364/ol.29.001285 · Cited by 114
Self-citationTowards oncological application of Raman spectroscopy
Nijssen, A., Koljenović, S., Schut, T. C. B., Caspers, P. J., & Puppels, G. J. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200810055 · Cited by 113
Yao, K., Takaki, Y., Matsui, T., Iwashita, A., Anagnostopoulos, G. K., Kaye, P., & Ragunath, K. (2008) · Gastrointestinal Endoscopy Clinics of North America · doi:10.1016/j.giec.2008.05.011 · Cited by 97
Delivery of nanojoule femtosecond pulses through large-core microstructured fibers
Ouzounov, D. G., Moll, K. D., Foster, M. A., Zipfel, W. R., Webb, W. W., & Gaeta, A. L. (2002) · Optics Letters · doi:10.1364/ol.27.001513 · Cited by 95
Three-dimensional nonlinear optical endoscopy
Fu, L., Jain, A., Cranfield, C. G., Xie, H., & Gu, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2756102 · Cited by 81
Miniature random-access fiber scanner for in vivo multiphoton imaging
Sawinski, J., & Denk, W. T. (2007) · Journal of Applied Physics · doi:10.1063/1.2763945 · Cited by 78
Spectral background and transmission characteristics of fiber optic imaging bundles
Udovich, J. A., Kirkpatrick, N. D., Kano, A. L., Rynes, A. W., Utzinger, U., & Gmitro, A. F. (2008) · Applied Optics · doi:10.1364/ao.47.004560 · Cited by 77
Liu, J. T. C., Helms, M. W., Mandella, M. J., Crawford, J. M., Kino, G. S., & Contag, C. H. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2008.12.3908 · Cited by 64
Spatial frequency response of color image sensors: Bayer color filters and Foveon X3
Hubel, P. M., Liu, J., & Guttosch, R. J. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.561568 · Cited by 62
Wilson, B. C. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2795688 · Cited by 55
Engelbrecht, C. J., Göbel, W., & Helmchen, F. (2009) · Optics Express · doi:10.1364/oe.17.006421 · Cited by 54
Self-citationPsychophysical thresholds and digital camera sensitivity: the thousand-photon limit
Feng, X., Farrell, J., & Wandell, B. A. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.587468 · Cited by 34
Cited by
Wang, J., & Dong, J. (2020) · Sensors · doi:10.3390/s20143981 · Cited by 77
Metadata
- Authors
- Lee, C. M., Engelbrecht, C. J., Soper, T. D., Helmchen, F., & Seibel, E. J.
- Venue
- Journal of Biophotonics
- Publisher
- Wiley
- Published
- 2010-05-18
- Volume
- 3
- Issue
- 5-6
- Pages
- 385-407
- ISSN
- 1864-063X (ISSN-L)
- 1864-0648
- OpenAlex
- W1998979002
- Cited by
- 281
- References
- 42
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.