The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Material fundamentals and clinical performance of plasma‐sprayed hydroxyapatite coatings: A review
Abstract
The clinical use of plasma‐sprayed hydroxyapatite (HA) coatings on metal implants has aroused as many controversies as interests over the last decade. Although faster and stronger fixation and more bone growth have been revealed, the performance of HA‐coated implants has been doubted. This article will initially address the fundamentals of the material selection, design, and processing of the HA coating and show how the coating microstructure and properties can be a good predictor of the expected behavior in the body. Further discussion will clarify the major concerns with the clinical use of HA coatings and introduce a comprehensive review concerning the outcomes experienced with respect to clinical practice over the past 5 years. A reflection on the results indicates that HA coatings can promote earlier and stronger fixation but exhibit a durability that can be related to the coating quality. Specific relationships between coating quality and clinical performance are being established as characterization methods disclose more information about the coating. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 58: 570–592, 2001
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
HARRIS, W. H. (1969) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196951040-00012 · Cited by 5,640
Banaszkiewicz, P. A. (2014) · Classic Papers in Orthopaedics · doi:10.1007/978-1-4471-5451-8_3 · Cited by 5,038
Handbook of Chemistry and Physics.
(1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-79-6-934_3 · Cited by 2,559
Structure and Chemistry of the Apatites and Other Calcium Orthophosphates
(1994) · Studies in Inorganic Chemistry · doi:10.1016/c2009-0-10247-7 · Cited by 2,527
An Introduction to Bioceramics
Hench, L. L., & Wilson, J. (1993) · WORLD SCIENTIFIC eBooks · doi:10.1142/2028 · Cited by 2,307
Osseointegration and its experimental background
Branemark, P.-I. (1983) · The Journal of Prosthetic Dentistry · doi:10.1016/s0022-3913(83)80101-2 · Cited by 2,084
Calcium Phosphate Ceramics as Hard Tissue Prosthetics
JARCHO, M. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198106000-00037 · Cited by 2,014
Crystal Structure of Hydroxyapatite
KAY, M. I., YOUNG, R. A., & POSNER, A. S. (1964) · Nature · doi:10.1038/2041050a0 · Cited by 1,391
Understanding and controlling the bone–implant interface
Puleo, D. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00160-x · Cited by 1,342
Plasma sprayed coatings of hydroxylapatite
De Groot, K., Geesink, R., Klein, C. P. A. T., & Serekian, P. (1987) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820211203 · Cited by 1,156
Harris, W. H. (1995) · PubMed · Cited by 732
Biodegradation and bioresorption of calcium phosphate ceramics
LeGeros, R. Z. (1993) · Clinical Materials · doi:10.1016/0267-6605(93)90049-d · Cited by 647
Karrholm, J., Borssen, B., Lowenhielm, G., & Snorrason, F. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b6.7983118 · Cited by 622
Encyclopedic handbook of biomaterials and bioengineering
Wise, D. L. (1995) · Cited by 584
Bonfield, W., Grynpas, M. D., Tully, A. E., Bowman, J., & Abram, J. (1981) · Biomaterials · doi:10.1016/0142-9612(81)90050-8 · Cited by 546
Bonding of bone to apatite-coated implants
Geesink, R., de Groot, K., & Klein, C. (1988) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.70b1.2828374 · Cited by 537
Radin, S. R., & Ducheyne, P. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270106 · Cited by 521
Søballe, K., Hansen, E. S., B.‐Rasmussen, H., Jørgensen, P. H., & Bünger, C. (1992) · Journal of Orthopaedic Research · doi:10.1002/jor.1100100216 · Cited by 506
Dickens, B., Schroeder, L. W., & Brown, W. E. (1974) · Journal of Solid State Chemistry · doi:10.1016/0022-4596(74)90030-9 · Cited by 495
Ducheyne, P., Radin, S., & King, L. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270105 · Cited by 467
SANDERS, H. J. (1984) · Chemical & Engineering News · doi:10.1021/cen-v062n028.p026 · Cited by 361
Six-year results of hydroxyapatite-coated total hip replacement
Geesink, R., & Hoefnagels, N. (1995) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.77b4.7615595 · Cited by 327
Localized osteolysis in stable, non-septic total hip replacement.
Jasty, M. J., Floyd, W. E., Schiller, A. L., Goldring, S. R., & Harris, W. H. (1986) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198668060-00014 · Cited by 326
The Various Stress Patterns of Press-Fit, Ingrown, and Cemented Femoral Stems
HUISKES, R. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199012000-00006 · Cited by 308
Radin, S. R., & Ducheyne, P. (1992) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00702942 · Cited by 298
Hydroxylapatite coating of porous implants improves bone ingrowth and interface attachment strength
Cook, S. D., Thomas, K. A., Delton, J. E., Volkman, T. K., Whitecloud, T. S., & Key, J. F. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260803 · Cited by 272
Weng, J. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00022-7 · Cited by 266
Filiaggi, M. J., Coombs, N. A., & Pilliar, R. M. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820251004 · Cited by 245
Tissue response to dense apatite implants in rats
Denissen, H. W., de Groot, K., Makkes, P. C., van den Hooff, A., & Klopper, P. J. (1980) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820140603 · Cited by 241
Age and disease-related changes in the mineral of bone
Grynpas, M. (1993) · Calcified Tissue International · doi:10.1007/bf01673403 · Cited by 235
Bioactive Ceramic Prosthetic Coatings
Ducheyne, P., & Cuckler, J. M. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199203000-00014 · Cited by 218
Current Concepts in Orthopaedic Biomaterials and Implant Fixation
FRIEDMAN, R. J., BLACK, J., GALANTE, J. O., JACOBS, J. J., & SKINNER, H. B. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199307000-00017 · Cited by 210
Lima, R. S., Kucuk, A., & Berndt, C. C. (2001) · Surface and Coatings Technology · doi:10.1016/s0257-8972(00)00997-x · Cited by 206
Self-citationBiological Performance of Materials
Barbucci, R., Lamponi, S., & Magnani, A. (2000) · Chemistry at the Beginning of the Third Millennium · doi:10.1007/978-3-662-04154-3_8 · Cited by 184
Dhert, W. J. A., Klein, C. P. A. T., Jansen, J. A., van der Velde, E. A., Vriesde, R. C., Rozing, P. M., & de Groot, K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270116 · Cited by 179
Determining mineral content variations in bone using backscattered electron imaging
Bloebaum, R. D., Skedros, J. G., Vajda, E. G., Bachus, K. N., & Constantz, B. R. (1997) · Bone · doi:10.1016/s8756-3282(97)00015-x · Cited by 167
Osteolysis from a press-fit hydroxyapatite-coated implant
Bloebaum, R. D., & Dupont, J. A. (1993) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(09)80013-2 · Cited by 164
Harada, Y., Wang, J.-T., Doppalapudi, V. A., Willis, A. A., Jasty, M., Harris, W. H., Nagase, M., & Goldring, S. R. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199605)31:1<19::aid-jbm3>3.0.co;2-t · Cited by 115
The production and characterization of hydroxyapatite (HA) powders
Kweh, S. W. K., Khor, K. A., & Cheang, P. (1999) · Journal of Materials Processing Technology · doi:10.1016/s0924-0136(99)00061-8 · Cited by 109
Analysis of the External Fixator Pin-Bone Interface
Pettine, K. A., Chao, E. Y. S., & KELLY, P. J. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199308000-00004 · Cited by 101
Aro, H. T., Markel, M. D., & Chao, E. Y. S. (1993) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199311000-00022 · Cited by 93
Gatewood, R. R., Cobb, C. M., & Killoy, W. J. (1993) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.1993.040201.x · Cited by 83
Mineral apposition rates of human cancellous bone at the interface of porous coated implants
Bloebaum, R. D., Bachus, K. N., Momberger, N. G., & Hofmann, A. A. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280503 · Cited by 80
Toxicity of hydroxyapatite in vitro: the effect of particle size
Evans, E. J. (1991) · Biomaterials · doi:10.1016/0142-9612(91)90054-e · Cited by 80
Callahan, T., Gantenberg, J., & Sands, B. (1994) · doi:10.1520/stp25193s · Cited by 50
Development of a new percutaneous access device for implantation in soft tissues
Jansen, J. A., van der Waerden, J. P. C. M., & de Groot, K. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820251210 · Cited by 50
Cited by
Navarro, M., Michiardi, A., Castaño, O., & Planell, J. A. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0151 · Cited by 1,513
Bioceramics of calcium orthophosphates
Dorozhkin, S. V. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.050 · Cited by 1,338
A Review on Biomedical Titanium Alloys: Recent Progress and Prospect
Zhang, L., & Chen, L. (2019) · Advanced Engineering Materials · doi:10.1002/adem.201801215 · Cited by 1,100
Eliaz, N., & Metoki, N. (2017) · Materials · doi:10.3390/ma10040334 · Cited by 1,088
Bioceramics: Past, present and for the future
Best, S. M., Porter, A. E., Thian, E. S., & Huang, J. (2008) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2007.12.001 · Cited by 851
Metadata
- Authors
- Sun, L., Berndt, C. C., Gross, K. A., & Kucuk, A.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 2001-01
- Volume
- 58
- Issue
- 5
- Pages
- 570-592
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2012245641
- Cited by
- 1,065
- References
- 47
- FWCI
- 12.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.