The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Isolation of predominantly submicron‐sized UHMWPE wear particles from periprosthetic tissues
Abstract
A method of tissue digestion using sodium hydroxide was applied to the isolation and recovery of ultra‐high‐molecular‐weight polyethylene (UHMWPE) particles from tissues around failed total hip replacements. Density gradient ultracentrifugation of the digested tissues was performed to separate the UHMWPE from cell debris and other particulates. Fourier transform infrared spectroscopy and differential scanning calorimetry (DSC) verified that the recovered particles were UHMWPE. When viewed by scaning electron microscopy, individual particles were clearly observed and were either rounded or elongated. The majority were submicron in size. The application of this method to the study or particles from periprosthetic tissues may elucidate aspects of biomaterial particles size and shape that are important to the biologic response to, and clinical outcome of, total joint replacement. © 1995 John wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schmalzried, T. P., Jasty, M., & Harris, W. H. (1992) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199274060-00006 · Cited by 989
Self-citationMechanism and Clinical Significance of Wear Debris-Induced Osteolysis
AMSTUTZ, H. C., CAMPBELL, P., KOSSOVSKY, N., & CLARKE, I. C. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199203000-00003 · Cited by 670
Self-citationHowie, D. W., Vernon-Roberts, B., Oakeshott, R., & Manthey, B. (1988) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198870020-00015 · Cited by 390
Composition and morphology of wear debris in failed uncemented total hip replacement
Shanbhag, A., Jacobs, J., Glant, T., Gilbert, J., Black, J., & Galante, J. (1994) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.76b1.8300684 · Cited by 387
Anthony, P., Gie, G., Howie, C., & Ling, R. (1990) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.72b6.2246300 · Cited by 319
Aggressive granulomatous lesions associated with hip arthroplasty. Immunopathological studies.
Santavirta, S., Konttinen, Y. T., Bergroth, V, Eskola, A., Tallroth, K., & Lindholm, T. S. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072020-00014 · Cited by 318
Size of metallic and polyethylene debris particles in failed cemented total hip replacements
Lee, J., Salvati, E., Betts, F., DiCarlo, E., Doty, S., & Bullough, P. (1992) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.74b3.1587882 · Cited by 176
GOODMAN, S. B., CHIN, R. C., CHIOU, S. S., SCHURMAN, D. J., WOOLSON, S. T., & MASADA, M. P. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198907000-00017 · Cited by 168
Cited by
Biological reactions to wear debris in total joint replacement
Ingham, E., & Fisher, J. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535219 · Cited by 708
The role of macrophages in osteolysis of total joint replacement
Ingham, E., & Fisher, J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.035 · Cited by 667
Moro, T., Takatori, Y., Ishihara, K., Konno, T., Takigawa, Y., Matsushita, T., Chung, U.-I., Nakamura, K., & Kawaguchi, H. (2004) · Nature Materials · doi:10.1038/nmat1233 · Cited by 572
The Minderoo-Monaco Commission on Plastics and Human Health
Landrigan, P. J., Raps, H., Cropper, M., Bald, C., Brunner, M., Canonizado, E. M., Charles, D., Chiles, T. C., Donohue, M. J., Enck, J., et al. (2023) · Annals of Global Health · doi:10.5334/aogh.4056 · Cited by 471
Doorn, P. F., Campbell, P. A., Worrall, J., Benya, P. D., McKellop, H. A., & Amstutz, H. C. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199810)42:1<103::aid-jbm13>3.0.co;2-m · Cited by 431
Self-citation
Metadata
- Authors
- Campbell, P., Ma, S., Yeom, B., McKellop, H., Schmalzried, T. P., & Amstutz, H. C.
- Venue
- Journal of Biomedical Materials Research
- Publisher
- Wiley
- Published
- 1995-01
- Volume
- 29
- Issue
- 1
- Pages
- 127-131
- ISSN
- 0021-9304 (ISSN-L)
- 1097-4636
- OpenAlex
- W2130111797
- Cited by
- 352
- References
- 8
- FWCI
- 14.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.