Novel complexation hydrogels for oral peptide delivery: In vitro evaluation of their cytocompatibility and insulin‐transport enhancing effects using Caco‐2 cell monolayers
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Poly[methacrylic acid‐grafted‐poly(ethylene glycol)] [P(MAA‐g‐EG)] is a complexation hydrogel molecularly designed for oral peptide delivery. In this work, the cytotoxicity and insulin‐transport enhancing effect of P(MAA‐g‐EG) microparticles on intestinal epithelial cells were evaluated using Caco‐2 cell monolayers. A series of P(MAA‐g‐EG) microparticles with different polymer compositions were prepared by a photo‐initiated free radical solution polymerization and subsequent pulverization. The hydrogel microparticles were preswollen in either Ca 2+‐containing (CM+) or Ca 2+‐free medium (CM−; pH 7.4) and applied to the apical side of the Caco‐2 monolayers. No significant cytotoxic effects, as determined by a calorimetric assay with P(MAA‐g‐EG) microparticles preswollen in the CM+, were observed at doses ranging from 3 to 31 mg/cm 2 of cell monolayer. Transepithelial electrical resistance (TEER) measurements showed that the P(MAA‐g‐EG) microparticles induced a Ca 2+ concentration‐dependent lowering in TEER values. The reduction effect in CM− media was greater than that in CM+ media (17 ± 2% reduction in CM+ and 45 ± 3% reduction in CM−, respectively). Insulin transport in the presence of the preswollen P(MAA‐g‐EG) microparticles was also strongly depended on the Ca 2+ concentration in the medium. The respective estimated permeability for insulin alone and the insulin with hydrogels in CM+ were 0.77 and 1.16 × 10−8 cm/s, whereas those in CM− were 1.18 and 24.78 × 10−8 cm/s. The results demonstrate that the P(MAA‐g‐EG) hydrogel microparticles could be used as a cytocompatible carrier possessing the transport‐enhancing effect of insulin on the intestinal epithelial cells. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 609–617, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels in pharmaceutical formulations
Peppas, N. (2000) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(00)00090-4 · Cited by 4,011
Self-citationPhysicochemical Foundations and Structural Design of Hydrogels in Medicine and Biology
Peppas, N. A., Huang, Y., Torres-Lugo, M., Ward, J. H., & Zhang, J. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.9 · Cited by 1,016
Self-citationBiologically erodable microspheres as potential oral drug delivery systems
Mathiowitz, E., Jacob, J. S., Jong, Y. S., Carino, G. P., Chickering, D. E., Chaturvedi, P., Santos, C. A., Vijayaraghavan, K., Montgomery, S., Bassett, M., et al. (1997) · Nature · doi:10.1038/386410a0 · Cited by 823
Cited by
Approaches for enhancing oral bioavailability of peptides and proteins
Renukuntla, J., Vadlapudi, A. D., Patel, A., Boddu, S. H. S., & Mitra, A. K. (2013) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2013.02.030 · Cited by 681
Materials for oral delivery of proteins and peptides
Brown, T. D., Whitehead, K. A., & Mitragotri, S. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0156-6 · Cited by 520
pH-Responsive carriers for oral drug delivery: Challenges and opportunities of current platforms
Liu, L., Yao, W., Rao, Y., Lu, X., & Gao, J. (2017) · Drug Delivery · doi:10.1080/10717544.2017.1279238 · Cited by 420
Influence of molecular weight on oral absorption of water soluble chitosans
Chae, S. Y., Jang, M.-K., & Nah, J.-W. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.10.012 · Cited by 383
Therapeutic applications of hydrogels in oral drug delivery
Sharpe, L. A., Daily, A. M., Horava, S. D., & Peppas, N. A. (2014) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2014.902047 · Cited by 354
“Previous studies have demonstrated the successful use of this hydrogel system for the oral delivery of proteins, such as insulin [66,67], calcitonin [68,69] and IFN-a [69].”
BackgroundSelf-citationBiodegradable poly(ɛ-caprolactone)–poly(ethylene glycol) copolymers as drug delivery system
Wei, X., Gong, C., Gou, M., Fu, S., Guo, Q., Shi, S., Luo, F., Guo, G., Qiu, L., & Qian, Z. (2009) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2009.07.033 · Cited by 352
Choonara, B. F., Choonara, Y. E., Kumar, P., Bijukumar, D., du Toit, L. C., & Pillay, V. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.07.006 · Cited by 311
Wong, C. Y., Al-Salami, H., & Dass, C. R. (2018) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2017.12.036 · Cited by 269
Hydrogels for oral delivery of therapeutic proteins
Peppas, N. A., Wood, K. M., & Blanchette, J. O. (2004) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.4.6.881 · Cited by 161
“This network attains physical integrity and is made insoluble due to the presence of chemical and/or physical crosslinks [1,9,10].”
BackgroundSelf-citationThermosensitive Polymeric Hydrogels As Drug Delivery Systems
Gong, C., Qi, T., Wei, X., Qu, Y., Wu, Q., Luo, F., & Qian, Z. (2012) · Current Medicinal Chemistry · doi:10.2174/09298673130109 · Cited by 161
“Especially, the thermosensitive physical crosslinked in situ gel-forming hydrogels with sol-gel transition have been extensively studied due to their potential biomedical applications, including controlled drug delivery, cell encapsulation and tissue engineering [13-24].”
Background
Metadata
- Authors
- Ichikawa, H., & Peppas, N. A.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-10-06
- Volume
- 67A
- Issue
- 2
- Pages
- 609-617
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2120812026
- Cited by
- 91
- References
- 3
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.