Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 190

The DOI matches its Crossref record.

Elastic biodegradable poly(glycolide‐co‐caprolactone) scaffold for tissue engineering

Open access
Lee, Soo‐Hong, Kim, Byung‐Soo, Kim, Soo Hyun, Choi, Sung Won, Jeong, Sung In, Kwon, Il Keun, Kang, Sun Woong, Nikolovski, Janeta, Mooney, David J., Han, Yang‐Kyoo, Kim, Young Ha·2003·Journal of Biomedical Materials Research Part A

Abstract

Cyclic mechanical strain has been demonstrated to enhance the development and function of engineered smooth muscle (SM) tissues, and it would be necessary for the development of the elastic scaffolds if one wishes to engineer SM tissues under cyclic mechanical loading. This study reports on the development of an elastic scaffold fabricated from a biodegradable polymer. Biodegradable poly(glycolide‐co‐caprolactone) (PGCL) copolymer was synthesized from glycolide and ϵ‐caprolactone in the presence of stannous octoate as catalyst. The copolymer was characterized by 1 H‐NMR, gel permeation chromatography and differential scanning calorimetry. Scaffolds for tissue engineering applications were fabricated from PGCL copolymer using the solvent‐casting and particle‐leaching technique. The PGCL scaffolds produced in this fashion had open pore structures (average pore size = 250 μm) without the usual nonporous skin layer on external surfaces. Mechanical testing revealed that PGCL scaffolds were far more elastic than poly(lactic‐co‐glycolic acid) (PLGA) scaffolds fabricated using the same method. Tensile mechanical tests indicated that PGCL scaffolds could withstand an extension of 250% without cracking, which was much higher than withstood by PLGA scaffolds (10–15%). In addition, PGCL scaffolds achieved recoveries exceeding 96% at applied extensions of up to 230%, whereas PLGA scaffolds failed (cracked) at an applied strain of 20%. Dynamic mechanical tests showed that the permanent deformation of the PGCL scaffolds in a dry condition produced was less than 4% of the applied strain, when an elongation of 20% at a frequency of 1 Hz (1 cycle per second) was applied for 6 days. Moreover, PGCL scaffolds in a buffer solution also had permanent deformations less than 5% of the applied strain when an elongation of 10% at a frequency of 1 Hz was applied for 2 days. The usefulness of the PGCL scaffolds was demonstrated by engineering SM tissues in vivo. This study shows that the elastic PGCL scaffolds produced in this study could be used to engineer SM‐containing tissues (e.g. blood vessels and bladders) in mechanically dynamic environments. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 66A: 29–37, 2003

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.10497

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 190

Metadata

Authors
Lee, S., Kim, B., Kim, S. H., Choi, S. W., Jeong, S. I., Kwon, I. K., Kang, S. W., Nikolovski, J., Mooney, D. J., Han, Y., & Kim, Y. H.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2003-06-03
Volume
66A
Issue
1
Pages
29-37
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2032345944
Cited by
190
References
0
FWCI
5.79
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Elastic biodegradable poly(glycolide‐co‐caprolactone) scaffold for tissue engineering. https://app.cochat.ai/papers/10.1002/jbm.a.10497
The paper
Lee, S., Kim, B., Kim, S. H., Choi, S. W., Jeong, S. I., Kwon, I. K., Kang, S. W., Nikolovski, J., Mooney, D. J., Han, Y., & Kim, Y. H. (2003). Elastic biodegradable poly(glycolide‐co‐caprolactone) scaffold for tissue engineering. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.10497

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.