The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Performance of degradable composite bone repair products made via three‐dimensional fabrication techniques
Abstract
This study analyzed the in vivo performance of composite degradable bone repair products fabricated using the TheriForm™ process, a solid freeform fabrication (SFF) technique, in a rabbit calvarial defect model at 8 weeks. Scaffolds were composed of polylactic‐co‐glycolic acid (PLGA) polymer with 20% w/w β‐tricalcium phosphate (β‐TCP) ceramic with engineered macroscopic channels, a controlled porosity gradient, and a controlled pore size for promotion of new bone ingrowth. Scaffolds with engineered macroscopic channels and a porosity gradient had higher percentages of new bone area compared to scaffolds without engineered channels. These scaffolds also had higher percentages of new bone area compared to unfilled control defects, suggesting that scaffold material and design combinations could be tailored to facilitate filling of bony defects. This proof‐of‐concept study demonstrated that channel size, porosity, and pore size can be controlled and used to influence new bone formation and calvarial defect healing. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 66A: 283–291, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Orthopaedic applications for PLA‐PGA biodegradable polymers
Athanasiou, K., Agrawal, C., Barber, F., & Burkhart, S. (1998) · Arthroscopy · doi:10.1016/s0749-8063(98)70099-4 · Cited by 487
Cited by
Freeze casting of hydroxyapatite scaffolds for bone tissue engineering
Deville, S., Saiz, E., & Tomsia, A. P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.06.028 · Cited by 873
Cell proliferation and migration in silk fibroin 3D scaffolds
Mandal, B. B., & Kundu, S. C. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.02.006 · Cited by 583
Poly (lactic acid)-based biomaterials for orthopaedic regenerative engineering
Narayanan, G., Vernekar, V. N., Kuyinu, E. L., & Laurencin, C. T. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.04.015 · Cited by 484
Vascularized Bone Tissue Engineering: Approaches for Potential Improvement
Nguyen, L. H., Annabi, N., Nikkhah, M., Bae, H., Binan, L., Park, S., Kang, Y., Yang, Y., & Khademhosseini, A. (2012) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2012.0012 · Cited by 313
Yedekçi, B., Tezcaner, A., Yılmaz, B., Demir, T., & Evis, Z. (2022) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2021.104941 · Cited by 35
Metadata
- Authors
- Roy, T. D., Simon, J. L., Ricci, J. L., Rekow, E. D., Thompson, V. P., & Parsons, J. R.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-07-08
- Volume
- 66A
- Issue
- 2
- Pages
- 283-291
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2020594734
- Cited by
- 262
- References
- 1
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of degradable composite bone repair products made via three‐dimensional fabrication techniques. https://app.cochat.ai/papers/10.1002/jbm.a.10582
- The paper
- Roy, T. D., Simon, J. L., Ricci, J. L., Rekow, E. D., Thompson, V. P., & Parsons, J. R. (2003). Performance of degradable composite bone repair products made via three‐dimensional fabrication techniques. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.10582
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.