Fibrous encapsulation of single polymer microfibers depends on their vertical dimension in subcutaneous tissue
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The purpose of this research was to investigate possible explanations for why small‐diameter microfiber implants do not experience encapsulation in subcutaneous tissue as do large‐diameter fiber implants. Single polypropylene microfibers of approximately rectangular cross‐section with rounded edges were twisted about their longitudinal axes and affixed at their ends to polycarbonate frames. The frames were implanted in rat subcutaneous dorsum for a 5‐week period, then removed and processed for light microscopy analysis. Fibrous capsule presence/absence and thickness around the implants were assessed, and their relationships to geometric features of the fibers investigated. A logistic regression analysis between presence/absence of a fibrous capsule and geometric features of interest demonstrated strong predictive ability (92.4% correct predictions) for implant height and a well‐defined threshold separating the presence and absence of a fibrous capsule at 5.9 μm (p < 0.001). Implant height was defined as the vertical distance between the most superficial and deepest level of the implant. This 5.9‐μm threshold value of implant height is comparable to the 6.0‐μm diameter threshold for capsule presence/absence in fibers of circular cross‐section [Sanders et al. J Biomed Mater Res 2000; 52(1):231–237]. Fiber major axis length, minor axis length, aspect ratio, surface area per unit length, implant width, and implant angle did not show similar predictive ability or a well‐defined threshold separating the presence and absence of a fibrous capsule. It is reasoned that for fibers greater than the threshold height of 5.9 μm, separation of collagen fibers in the extracellular matrix creates dead space regions adjacent to the fibers that attract inflammatory cells and stimulate fibrous capsule formation. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 1181–1187, 2003
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sanders, J. E., Cassisi, D. V., Neumann, T., Golledge, S. L., Zachariah, S. G., Ratner, B. D., & Bale, S. D. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10525 · Cited by 35
Self-citation
Cited by
Jagur‐Grodzinski, J. (2006) · Polymers for Advanced Technologies · doi:10.1002/pat.729 · Cited by 394
The Foreign Body Response Demystified
Chandorkar, Y., K, R., & Basu, B. (2019) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.8b00252 · Cited by 201
Advanced strategies to thwart foreign body response to implantable devices
Capuani, S., Malgir, G., Chua, C. Y. X., & Grattoni, A. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10300 · Cited by 195
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500317 · Cited by 125
Helton, K. L., Ratner, B. D., & Wisniewski, N. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500318 · Cited by 102
Metadata
- Authors
- Sanders, J. E., & Rochefort, J. R.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2003-11-04
- Volume
- 67A
- Issue
- 4
- Pages
- 1181-1187
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1996951593
- Cited by
- 32
- References
- 1
- FWCI
- 1.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fibrous encapsulation of single polymer microfibers depends on their vertical dimension in subcutaneous tissue. https://app.cochat.ai/papers/10.1002/jbm.a.20027
- The paper
- Sanders, J. E., & Rochefort, J. R. (2003). Fibrous encapsulation of single polymer microfibers depends on their vertical dimension in subcutaneous tissue. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.20027
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.