The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Conducting polymers grown in hydrogel scaffolds coated on neural prosthetic devices
Open accessAbstract
The conducting polymer polypyrrole (PPy) was electrochemically grown on hydrogel scaffolds deposited on the surface of microfabricated neural prosthetic devices. It is shown that the pyrrole monomer can be grown vertically through the hydrogel layer up to the surface without affecting the adjacent sites on the probes. The electrochemical properties of the conducting polymer‐modified hydrogels were studied by impedance spectroscopy and cyclic voltammetry. It is also found that the conducting polymers could still be readily grown through the hydrogel after the microstructure is disrupted by freeze drying. Impedance measurements at the biologically important frequency of 1 kHz showed that the minimum impedance of this polymer‐modified hydrogel was 7 kΩ. This is much lower than the minimum impedance of polypyrrole film (∼100 kΩ). © 2004 Wiley Periodicals, Inc. J Biomed Mater Res 71A: 577–585, 2004
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · doi:10.1016/c2009-0-02433-7 · Cited by 5,127
High power electrochemical capacitors based on carbon nanotube electrodes
Niu, C., Sichel, E. K., Hoch, R., Moy, D., & Tennent, H. (1997) · Applied Physics Letters · doi:10.1063/1.118568 · Cited by 1,408
Stimulation of neurite outgrowth using an electrically conducting polymer
Schmidt, C. E., Shastri, V. R., Vacanti, J. P., & Langer, R. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.17.8948 · Cited by 1,071
Mesoporous Platinum Films from Lyotropic Liquid Crystalline Phases
Attard, G. S., Bartlett, P. N., Coleman, N. R. B., Elliott, J. M., Owen, J. R., & Wang, J. H. (1997) · Science · doi:10.1126/science.278.5339.838 · Cited by 965
Foulds, N. C., & Lowe, C. R. (1986) · Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases · doi:10.1039/f19868201259 · Cited by 532
Surface modification of neural recording electrodes with conducting polymer/biomolecule blends
Cui, X., Lee, V. A., Raphael, Y., Wiler, J. A., Hetke, J. F., Anderson, D. J., & Martin, D. C. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200108)56:2<261::aid-jbm1094>3.0.co;2-i · Cited by 530
Self-citationNovel alginate sponges for cell culture and transplantation
Shapiro, L., & Cohen, S. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00181-0 · Cited by 495
Conducting Polymer Hydrogels as 3D Electrodes: Applications for Supercapacitors
Ghosh, S., & Inganäs, O. (1999) · Advanced Materials · doi:10.1002/(sici)1521-4095(199910)11:14<1214::aid-adma1214>3.0.co;2-3 · Cited by 407
Conductive electroactive polymers : intelligent materials systems
Wallace, G. G., Spinks, G. M., Kane‐Maguire, L. A. P., & Teasdale, P. R. (2003) · Griffith Research Online · Cited by 402
Ratner, B. D., Hoffman, A. S., Schoen, F. J., & Lemons, J. E. (1996) · Biomaterials Science · doi:10.1016/b978-012582460-6/50002-5 · Cited by 385
Characterization of implantable biosensor membrane biofouling
Wisniewski, N., Moussy, F., & Reichert, W. M. (2000) · Fresenius' Journal of Analytical Chemistry · doi:10.1007/s002160051556 · Cited by 350
Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343
Cui, X., Hetke, J. F., Wiler, J. A., Anderson, D. J., & Martin, D. C. (2001) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(01)00637-9 · Cited by 330
Self-citationPernaut, J.-M., & Reynolds, J. R. (2000) · The Journal of Physical Chemistry B · doi:10.1021/jp994274o · Cited by 293
Polypyrrole-heparin composites as stimulus-responsive substrates for endothelial cell growth
Garner, B., Georgevich, A., Hodgson, A. J., Liu, L., & Wallace, G. G. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199902)44:2<121::aid-jbm1>3.0.co;2-a · Cited by 279
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Activated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 227
Hydrogels and Biodegradable Polymers for Bioapplications
(1996) · ACS Symposium Series · doi:10.1021/bk-1996-0627 · Cited by 195
A preliminary assessment of poly(pyrrole) in nerve guide studies
Williams, R. L., & Doherty, P. J. (1994) · Journal of Materials Science: Materials in Medicine · doi:10.1007/bf00058978 · Cited by 166
Stable long-term recordings from cat peripheral nerves
Stein, R. B., Nichols, T. R., Jhamandas, J., Davis, L., & Charles, D. (1977) · Brain Research · doi:10.1016/0006-8993(77)90233-5 · Cited by 160
Electroformation of conducting polymers in a hydrogel support matrix
Kim, B. C., Spinks, G. M., Wallace, G. G., et al. (2000) · Polymer · doi:10.1016/s0032-3861(99)00308-0 · Cited by 78
Chronic recording of regenerating viiith nerve axons with a sieve electrode
Mensinger, A. F., Anderson, D. J., Buchko, C. J., Johnson, M. A., Martin, D. C., Tresco, P. A., Silver, R. B., & Highstein, S. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.611 · Cited by 76
Self-citationPolymer Hydrogel Microelectrodes for Neural Communication
Nyberg, T., Inganäs, O., & Jerregård, H. (2002) · Biomedical Microdevices · doi:10.1023/a:1014219828983 · Cited by 70
Surgical Implantation and Biocompatibility of Central Nervous System Auditory Prostheses
Niparko, J. K., Altschuler, R. A., Wiler, J. A., Xue, X., & Anderson, D. J. (1989) · Annals of Otology Rhinology & Laryngology · doi:10.1177/000348948909801209 · Cited by 62
Hodgson, A. J., John, M. J., Campbell, T. E., Georgevich, A., Woodhouse, S., Aoki, T., Ogata, N., & Wallace, G. G. (1996) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.232137 · Cited by 44
Impedance spectroscopy of protein polymer modified silicon micromachined probes
Athreya, S. A., & Martin, D. C. (1999) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(98)00223-4 · Cited by 28
Self-citation
Cited by
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Conductive polymers: Towards a smart biomaterial for tissue engineering
Balint, R., Cassidy, N. J., & Cartmell, S. H. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.02.015 · Cited by 1,777
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Conducting‐Polymer Nanotubes for Controlled Drug Release
Abidian, M. R., Kim, D. ‐., & Martin, D. C. (2006) · Advanced Materials · doi:10.1002/adma.200501726 · Cited by 869
Self-citationElectrospinning polyaniline-contained gelatin nanofibers for tissue engineering applications
Li, M., Guo, Y., Wei, Y., MacDiarmid, A. G., & Lelkes, P. I. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.037 · Cited by 856
Metadata
- Authors
- Kim, D., Abidian, M., & Martin, D. C.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2004-10-27
- Volume
- 71A
- Issue
- 4
- Pages
- 577-585
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2143252380
- Cited by
- 289
- References
- 26
- FWCI
- 8.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.