The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Use of Conducting Electroactive Polymers for Drug Delivery and Sensing of Bioactive Molecules. A Redox Chemistry Approach
Abstract
We have examined the properties of polypyrrole (PPy) as a model electroactive membrane which can simultaneously serve as a medium sensing, and bioactive molecule releasing, material using optical spectroscopic, potentiometric, and conductometric methods. In particular, PPy membranes can sense hydrazine in aqueous solution with linear logarithmic potentiometric and conductometric response s between 10 -4 and 10 -1 M. The sensing properties of the PPy membranes are discussed in terms of both its redox properties and specific acid−base behavior. Adenosine triphosphate (ATP) has been used as a model drug which is easily loaded into PPy during electrochemical synthesis. ATP release processes from PPy/ATP membranes have been studied spectroscopically using electrochemical and chemical triggering. Electrochemical triggering allowed ATP to be delivered with a variety of release profiles and adjustable rates (up to 20 μg cm -2 min -1 for a 10 μm thick membrane). The mass transfer through the membranes has been successfully treated using a simple diffusion model ( D ∼ 5 × 10 -9 cm 2 s -1 ) and discussed with regards to the polymer's structure and potential drug delivery device applications. Hydrazine (0.1 M) and alkaline medium (pH 12) have been used as chemical triggers for ATP release from PPy/ATP membranes. The amount of ATP released was reduced relative to the electrochemically released amount due to inhibited diffusion of reagents into the membranes. The release profiles have been established and demonstrate the viability of a controlled-delivery device using conducting polymers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polymeric systems for controlled drug release
Uhrich, K. E., Cannizzaro, S. M., Langer, R. S., & Shakesheff, K. M. (1999) · Chemical Reviews · doi:10.1021/cr940351u · Cited by 2,633
Langer, R. (1990) · Science · doi:10.1126/science.2218494 · Cited by 1,778
A review of the immobilization of enzymes in electropolymerized films
Barlett, P. N., & Cooper, J. M. (1993) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)80001-x · Cited by 472
Cited by
Electroconductive hydrogels: Synthesis, characterization and biomedical applications
Guiseppi-Elie, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.12.052 · Cited by 646
Next-generation probes, particles, and proteins for neural interfacing
Rivnay, J., Wang, H., Fenno, L., Deisseroth, K., & Malliaras, G. G. (2017) · Science Advances · doi:10.1126/sciadv.1601649 · Cited by 514
Electrically Controlled Drug Delivery from Biotin‐Doped Conductive Polypyrrole
George, P. M., LaVan, D. A., Burdick, J. A., Chen, C. ‐., Liang, E., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501242 · Cited by 320
Kim, D. ‐., Richardson‐Burns, S. M., Hendricks, J. L., Sequera, C., & Martin, D. C. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200500594 · Cited by 299
Cui, X., & Martin, D. C. (2003) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(02)00427-2 · Cited by 160
Metadata
- Authors
- Pernaut, J.-M., & Reynolds, J. R.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2000-03-30
- Volume
- 104
- Issue
- 17
- Pages
- 4080-4090
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W1967110735
- Cited by
- 293
- References
- 3
- FWCI
- 20.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of Conducting Electroactive Polymers for Drug Delivery and Sensing of Bioactive Molecules. A Redox Chemistry Approach. https://app.cochat.ai/papers/10.1021/jp994274o
- The paper
- Pernaut, J.-M., & Reynolds, J. R. (2000). Use of Conducting Electroactive Polymers for Drug Delivery and Sensing of Bioactive Molecules. A Redox Chemistry Approach. The Journal of Physical Chemistry B. https://doi.org/10.1021/jp994274o
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.