Osteoblasts respond to hydroxyapatite surfaces with immediate changes in gene expression
The DOI matches its Crossref record.
Abstract
Bone mineral contains hydroxyapatite (HA). This is the surface that mature osteoblasts and osteocytes interact with. Synthetic HA is widely used in orthopedic surgeries as an implant or implant coating. The bone‐like HA surfaces increase implant union and bone formation; however, the mechanisms accounting for this effect on osteoblasts are not known. In this study, we compared gene expression profiles of osteoblasts responding to HA or plastic surfaces for 24 h. Expression profiles were also compared between HA discs processed with gravity‐sieved compared with combined gravity and air‐jet‐sieved HA powders. The latter, composed of smaller HA particles, exhibits an increase in grain boundary surface area. Discs made with either HA powder similarly up‐regulated osteoblast expression of 10 genes (including proliferin 3, Glvr‐1, DMP‐1, and tenascin C) and down‐regulated 15 genes (such as osteoglycin) by more than 2‐fold compared with plastic surfaces. The overall changes are indicative of an immediate (24‐h) response to the HA surface and a trend toward osteoblast differentiation. In addition, subsets of modulated genes exist that are unique to each HA subtype. Taken together, we identified HA responsive genes evident within 24 h of surface contact, indicating a critical role for extracellular mineral surfaces in the regulation of osteoblast gene expression and phenotype. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res 71A: 108–117, 2004
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bone substitutes in orthopaedic surgery: from basic science to clinical practice
Campana, V., Milano, G., Pagano, E., Barba, M., Cicione, C., Salonna, G., Lattanzi, W., & Logroscino, G. (2014) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-014-5240-2 · Cited by 1,117
Fernandez de Grado, G., Keller, L., Idoux-Gillet, Y., Wagner, Q., Musset, A.-M., Benkirane-Jessel, N., Bornert, F., & Offner, D. (2018) · Journal of Tissue Engineering · doi:10.1177/2041731418776819 · Cited by 912
Collagen-Hydroxyapatite Composites for Hard Tissue Repair
Department of Materials, U. O. O., Wahl, D., & Czernuszka, J. (2006) · European Cells and Materials · doi:10.22203/ecm.v011a06 · Cited by 675
Biphasic calcium phosphate ceramics for bone reconstruction: A review of biological response
Bouler, J. M., Pilet, P., Gauthier, O., & Verron, E. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.01.076 · Cited by 500
Bioactive Coatings for Orthopaedic Implants—Recent Trends in Development of Implant Coatings
Zhang, B., Myers, D., Wallace, G., Brandt, M., & Choong, P. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms150711878 · Cited by 394
Calcium orthophosphate-based biocomposites and hybrid biomaterials
Dorozhkin, S. V. (2009) · Journal of Materials Science · doi:10.1007/s10853-008-3124-x · Cited by 300
Dawson, J. I., Wahl, D. A., Lanham, S. A., Kanczler, J. M., Czernuszka, J. T., & Oreffo, R. O. C. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.040 · Cited by 101
Cunniffe, G. M., Curtin, C. M., Thompson, E. M., Dickson, G. R., & O’Brien, F. J. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b06596 · Cited by 95
Tian, L., Zhang, Z., Tian, B., Zhang, X., & Wang, N. (2020) · RSC Advances · doi:10.1039/c9ra10275b · Cited by 77
Akkouch, A., Zhang, Z., & Rouabhia, M. (2014) · Journal of Biomaterials Applications · doi:10.1177/0885328213486705 · Cited by 76
Metadata
- Authors
- Xie, J., Baumann, M. J., & McCabe, L. R.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2004-08-13
- Volume
- 71A
- Issue
- 1
- Pages
- 108-117
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2081031736
- Cited by
- 134
- References
- 0
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.