The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Conducting Polymers, Hydrogels and Their Composites: Preparation, Properties and Bioapplications
Open accessAbstract
This review is focused on current state-of-the-art research on electroactive-based materials and their synthesis, as well as their physicochemical and biological properties. Special attention is paid to pristine intrinsically conducting polymers (ICPs) and their composites with other organic and inorganic components, well-defined micro- and nanostructures, and enhanced surface areas compared with those of conventionally prepared ICPs. Hydrogels, due to their defined porous structures and being filled with aqueous solution, offer the ability to increase the amount of immobilized chemical, biological or biochemical molecules. When other components are incorporated into ICPs, the materials form composites; in this particular case, they form conductive composites. The design and synthesis of conductive composites result in the inheritance of the advantages of each component and offer new features because of the synergistic effects between the components. The resulting structures of ICPs, conducting polymer hydrogels and their composites, as well as the unusual physicochemical properties, biocompatibility and multi-functionality of these materials, facilitate their bioapplications. The synergistic effects between constituents have made these materials particularly attractive as sensing elements for biological agents, and they also enable the immobilization of bioreceptors such as enzymes, antigen-antibodies, and nucleic acids onto their surfaces for the detection of an array of biological agents. Currently, these materials have unlimited applicability in biomedicine. In this review, we have limited discussion to three areas in which it seems that the use of ICPs and materials, including their different forms, are particularly interesting, namely, biosensors, delivery of drugs and tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Hydrogel: Preparation, characterization, and applications: A review
Ahmed, E. M. (2015) · Journal of Advanced Research · doi:10.1016/j.jare.2013.07.006 · Cited by 5,800
Synthesis of electrically conducting organic polymers: halogen derivatives of polyacetylene, (CH) x
Shirakawa, H., Louis, E. J., MacDiarmid, A. G., Chiang, C. K., & Heeger, A. J. (1977) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39770000578 · Cited by 3,867
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Printing three-dimensional tissue analogues with decellularized extracellular matrix bioink
Pati, F., Jang, J., Ha, D.-H., Won Kim, S., Rhie, J.-W., Shim, J.-H., Kim, D.-H., & Cho, D.-W. (2014) · Nature Communications · doi:10.1038/ncomms4935 · Cited by 1,904
Conducting polymers in biomedical engineering
Guimard, N. K., Gomez, N., & Schmidt, C. E. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.012 · Cited by 1,599
Biodegradable synthetic polymers: Preparation, functionalization and biomedical application
Tian, H., Tang, Z., Zhuang, X., Chen, X., & Jing, X. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.06.004 · Cited by 1,293
Hierarchical nanostructured conducting polymer hydrogel with high electrochemical activity
Pan, L., Yu, G., Zhai, D., Lee, H. R., Zhao, W., Liu, N., Wang, H., Tee, B. C.-K., Shi, Y., Cui, Y., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202636109 · Cited by 1,216
Brown, B. N., Valentin, J. E., Stewart-Akers, A. M., McCabe, G. P., & Badylak, S. F. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.11.040 · Cited by 896
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Cited by
Stimuli‐Responsive Biomolecule‐Based Hydrogels and Their Applications
Vázquez‐González, M., & Willner, I. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201907670 · Cited by 444
Conducting Polymers in the Design of Biosensors and Biofuel Cells
Ramanavicius, S., & Ramanavicius, A. (2020) · Polymers · doi:10.3390/polym13010049 · Cited by 307
Yin, P., Liu, Y., Xiao, L., & Zhang, C. (2021) · Polymers · doi:10.3390/polym13162834 · Cited by 42
Organic electronics for neuroprosthetics
Airaghi Leccardi, M. J. I., & Ghezzi, D. (2020) · Healthcare Technology Letters · doi:10.1049/htl.2019.0108 · Cited by 12
Metadata
- Authors
- Tomczykowa, M., & Plonska-Brzezinska, M.
- Venue
- Polymers
- Publisher
- MDPI AG
- Published
- 2019-02-17
- Volume
- 11
- Issue
- 2
- Pages
- 350
- ISSN
- 2073-4360 (ISSN-L)
- OpenAlex
- W2913907541
- Cited by
- 205
- References
- 14
- FWCI
- 12.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Conducting Polymers, Hydrogels and Their Composites: Preparation, Properties and Bioapplications. https://app.cochat.ai/papers/10.3390/polym11020350
- The paper
- Tomczykowa, M., & Plonska-Brzezinska, M. (2019). Conducting Polymers, Hydrogels and Their Composites: Preparation, Properties and Bioapplications. Polymers. https://doi.org/10.3390/polym11020350
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.