CoChat

The bone formation in vitro and mandibular defect repair using PLGA porous scaffolds

Ren, Tianbin, Ren, Jie, Jia, Xiaozhen, Pan, Kefeng · 2005 · Journal of Biomedical Materials Research Part A
Cited by 92

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Highly porous scaffolds of poly(lactide‐co‐glycolide) (PLGA) were prepared by solution‐casting/salt‐leaching method. The in vitro degradation behavior of PLGA scaffold was investigated by measuring the change of normalized weight, water absorption, pH, and molecular weight during degradation period. Mesenchymal stem cells (MSCs) were seeded and cultured in three‐dimensional PLGA scaffolds to fabricate in vitro tissue engineering bone, which was investigated by cell morphology, cell number and deposition of mineralized matrix. The proliferation of seeded MSCs and their differentiated function were demonstrated by experimental results. To compare the reconstructive functions of different groups, mandibular defect repair of rabbit was made with PLGA/MSCs tissue engineering bone, control PLGA scaffold, and blank group without scaffold. Histopathologic methods were used to estimate the reconstructive functions. The result suggests that it is feasible to regenerate bone tissue in vitro using PLGA foams with pore size ranging from 100–250 μm as scaffolding for the transplantation of MSCs, and the PLGA/MSCs tissue engineering bone can greatly promote cell growth and have better healing functions for mandibular defect repair. The defect can be completely recuperated after 3 months with PLGA/MSCs tissue engineering bone, and the contrastive experiments show that the defects could not be repaired with blank PLGA scaffold. PLGA/MSCs tissue engineering bone has great potential as appropriate replacement for successful repair of bone defect. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.30324

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 92

Metadata

Authors
Ren, T., Ren, J., Jia, X., & Pan, K.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2005-07-15
Volume
74A
Issue
4
Pages
562-569
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2087643240
Cited by
92
References
4
FWCI
5.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The bone formation in vitro and mandibular defect repair using PLGA porous scaffolds. https://app.cochat.ai/papers/10.1002/jbm.a.30324
The paper
Ren, T., Ren, J., Jia, X., & Pan, K. (2005). The bone formation in vitro and mandibular defect repair using PLGA porous scaffolds. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.30324

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.