The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In vitro cell infiltration and in vivo cell infiltration and vascularization in a fibrous, highly porous poly(D,L‐lactide) scaffold fabricated by cryogenic electrospinning technique
Abstract
One of the obstacles limiting the application of electrospun scaffolds for tissue engineering is the nanoscale pores that inhibit cell infiltration. In this article, we describe a technique that uses ice crystals as templates to fabricate cryogenic electrospun scaffolds (CES) with large three‐dimensional and interconnected pores using poly(D,L‐lactide) (PLA). Manipulating the humidity of the electrospinning environment the pore sizes are controlled. We are able to achieve pore sizes ranging from 900 ± 100 μm 2 to 5000 ± 2000 μm 2 depending on the relative humidity used. Our results show that cells infiltrated the CES up to 50 μm in thickness in vitro under static culture conditions whereas cells did not infiltrate the conventional electrospun scaffolds. In vivo studies demonstrated improved cell infiltration and vascularization in the CES compared with conventionally prepared electrospun scaffolds. In gaining control of the pore characteristics, we can then design CES that are optimized for specific tissue engineering applications. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frost formation on a vertical plate in simultaneously developing flow
Lee, Y. B., & Ro, S. T. (2002) · Experimental Thermal and Fluid Science · doi:10.1016/s0894-1777(02)00216-9 · Cited by 97 · cited 1×
“It has been established that the rate of ice crystal formation increases with humidity.(26) Hence, at high humidity, the proportion of ice crystals to fibers deposited is increased, resulting in a more open structure.”
Background
Cited by
Rnjak-Kovacina, J., Wise, S. G., Li, Z., Maitz, P. K. M., Young, C. J., Wang, Y., & Weiss, A. S. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.065 · Cited by 323
Phipps, M. C., Clem, W. C., Grunda, J. M., Clines, G. A., & Bellis, S. L. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.09.080 · Cited by 287
Chong, C., Wang, Y., Fathi, A., Parungao, R., Maitz, P. K., & Li, Z. (2019) · Burns · doi:10.1016/j.burns.2019.04.014 · Cited by 82
Zhao, H., Tang, J., Zhou, D., Weng, Y., Qin, W., Liu, C., Lv, S., Wang, W., & Zhao, X. (2020) · International Journal of Nanomedicine · doi:10.2147/ijn.s238800 · Cited by 51
Metadata
- Authors
- Leong, M. F., Rasheed, M. Z., Lim, T. C., & Chian, K. S.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2008-09-23
- Volume
- 91A
- Issue
- 1
- Pages
- 231-240
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2081648428
- Cited by
- 189
- References
- 1
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vitro cell infiltration and in vivo cell infiltration and vascularization in a fibrous, highly porous poly(D,L‐lactide) scaffold fabricated by cryogenic electrospinning technique. https://app.cochat.ai/papers/10.1002/jbm.a.32208
- The paper
- Leong, M. F., Rasheed, M. Z., Lim, T. C., & Chian, K. S. (2009). In vitro cell infiltration and in vivo cell infiltration and vascularization in a fibrous, highly porous poly(D,L‐lactide) scaffold fabricated by cryogenic electrospinning technique. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.32208
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.