Biocompatibility of poly(ethylene glycol)‐based hydrogels in the brain: An analysis of the glial response across space and time
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Poly(ethylene glycol) or PEG‐based hydrogels provide a useful methodology for tissue engineering and the controlled‐release of drugs within the central nervous system (CNS). To be successful, the local neuroinflammatory response to an implant must be well understood. Toward this end, the focus was to examine the localized recruitment and activation of microglia and astrocytes following implantation of PEG‐based hydrogels in the brain. Because they are of clinical relevance and may impact brain tissue differently, hydrogels with different mass loss profiles were examined. At all time points, a needle penetration in sham animals evoked a greater astrocytic response than hydrogel conditions. The astrocyte response that ensued varied with degradation rate. An attenuated response was present in more slowly degrading and nondegrading conditions. Relative to sham, hydrogel conditions attenuated the acute microglial response during the week after implant. By 56 days, microglial levels in shams decreased below the observed response in slowly degrading and nondegradable gels, which remained constant overtime. Although the inflammatory response to PEG‐based hydrogels was complex depending on degradation rates, the magnitude of the acute microglia response and the long‐term astrocyte response were attenuated suggesting the use of these materials for drug and cell delivery to the CNS. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2010.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Microglia: Active sensor and versatile effector cells in the normal and pathologic brain
Hanisch, U.-K., & Kettenmann, H. (2007) · Nature Neuroscience · doi:10.1038/nn1997 · Cited by 3,676
Pellerin, L., & Magistretti, P. J. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.22.10625 · Cited by 2,927
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Direct brain infusion of glial cell line–derived neurotrophic factor in Parkinson disease
Gill, S. S., Patel, N. K., Hotton, G. R., O'Sullivan, K., McCarter, R., Bunnage, M., Brooks, D. J., Svendsen, C. N., & Heywood, P. (2003) · Nature Medicine · doi:10.1038/nm850 · Cited by 1,290
Bush, T. G., Puvanachandra, N., Horner, C. H., Polito, A., Ostenfeld, T., Svendsen, C. N., Mucke, L., Johnson, M. H., & Sofroniew, M. V. (1999) · Neuron · doi:10.1016/s0896-6273(00)80781-3 · Cited by 1,116
Butovsky, O., Ziv, Y., Schwartz, A., Landa, G., Talpalar, A. E., Pluchino, S., Martino, G., & Schwartz, M. (2006) · Molecular and Cellular Neuroscience · doi:10.1016/j.mcn.2005.10.006 · Cited by 923
Microglia as neuroprotective, immunocompetent cells of the CNS
Streit, W. J. (2002) · Glia · doi:10.1002/glia.10154 · Cited by 919
Bryant, S. J., & Anseth, K. S. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1217 · Cited by 845
Cited by
Hydrogel interfaces for merging humans and machines
Yuk, H., Wu, J., & Zhao, X. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00483-4 · Cited by 661
The advanced role of carbon quantum dots in nanomedical applications
Devi, P., Saini, S., & Kim, K.-H. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.02.059 · Cited by 349
Elastocapillary self-assembled neurotassels for stable neural activity recordings
Guan, S., Wang, J., Gu, X., Zhao, Y., Hou, R., Fan, H., Zou, L., Gao, L., Du, M., Li, C., et al. (2019) · Science Advances · doi:10.1126/sciadv.aav2842 · Cited by 222
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
The future of neuroscience: flexible and wireless implantable neural electronics
McGlynn, E., Nabaei, V., Ren, E., Galeote‐Checa, G., Das, R., Curia, G., & Heidari, H. (2021) · Advanced Science · doi:10.1002/advs.202002693 · Cited by 115
Lampe, K. J., Mooney, R. G., Bjugstad, K. B., & Mahoney, M. J. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32787 · Cited by 112
Self-citation
Metadata
- Authors
- Bjugstad, K. B., Lampe, K., Kern, D. S., & Mahoney, M.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2010-08-19
- Volume
- 95A
- Issue
- 1
- Pages
- 79-91
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1967936088
- Cited by
- 118
- References
- 17
- FWCI
- 2.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.