In vivo performance of a phospholipid‐coated bioerodable elastomeric graft for small‐diameter vascular applications
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
There remains a great need for vascular substitutes for small‐diameter applications. The use of an elastomeric biodegradable material, enabling acute antithrombogenicity and long‐term in vivo remodeling, could be beneficial for this purpose. Conduits (1.3 mm internal diameter) were obtained by electrospinning biodegradable poly(ester urethane)urea (PEUU), and by luminally immobilizing a non‐thrombogenic, 2‐methacryloyloxyethyl phosphorylcholine (MPC) copolymer. Platelet adhesion was characterized in vitro after contact with ovine blood. The conduits were implanted as aortic interposition grafts in the rat for 4, 8, 12, and 24 weeks. Surface treatment resulted in a 10‐fold decrease in platelet adhesion compared to untreated material. Patency at 8 weeks was 92% for the coated grafts compared to 40% for the non‐coated grafts. Histology at 8 and 12 weeks demonstrated formation of cellularized neotissue consisting of aligned collagen and elastin. The lumen of the grafts was confluent with cells qualitatively aligned in the direction of blood flow. Immunohistochemistry suggested the presence of smooth muscle cells in the medial layer of the neotissue and endothelial cells lining the lumen. Mechanically, the grafts were less compliant than rat aortas prior to implantation (4.5 ± 2.0 × 10−4 mmHg−1 vs. 14.2 ± 1.1 × 10−4 mmHg−1, respectively), then after 4 weeks in vivo they approximated native values, but subsequently became stiffer again at later time points. The novel coated grafts exhibited promising antithrombogenic and mechanical properties for small‐diameter arterial revascularization. Further evaluation in vivo will be required to demonstrate complete remodeling of the graft into a native‐like artery. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part A:, 2011.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The design of scaffolds for use in tissue engineering. Part I. Traditional factors
Yang, S., Leong, K.-F., Du, Z., & Chua, C.-K. (2001) · Tissue Engineering · doi:10.1089/107632701753337645 · Cited by 2,234
The effect of scaffold degradation rate on three-dimensional cell growth and angiogenesis
Sung, H.-J., Meredith, C., Johnson, C., & Galis, Z. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.066 · Cited by 804
Cited by
Electrospun scaffolds for tissue engineering of vascular grafts
Hasan, A., Memic, A., Annabi, N., Hossain, M., Paul, A., Dokmeci, M. R., Dehghani, F., & Khademhosseini, A. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.08.022 · Cited by 742
Elastomeric biomaterials for tissue engineering
Chen, Q., Liang, S., & Thouas, G. A. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.05.003 · Cited by 564
Fast-degrading elastomer enables rapid remodeling of a cell-free synthetic graft into a neoartery
Wu, W., Allen, R. A., & Wang, Y. (2012) · Nature Medicine · doi:10.1038/nm.2821 · Cited by 431
Iwasaki, Y., & Ishihara, K. (2012) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/13/6/064101 · Cited by 346
Electrospun fibers for tissue engineering, drug delivery, and wound dressing
Goh, Y.-F., Shakir, I., & Hussain, R. (2013) · Journal of Materials Science · doi:10.1007/s10853-013-7145-8 · Cited by 318
Kucinska-Lipka, J., Gubanska, I., Janik, H., & Sienkiewicz, M. (2015) · Materials Science and Engineering: C · doi:10.1016/j.msec.2014.10.027 · Cited by 207
Liu, Q., Jiang, L., Shi, R., & Zhang, L. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.11.001 · Cited by 203
In Vivo Applications of Electrospun Tissue-Engineered Vascular Grafts: A Review
Rocco, K. A., Maxfield, M. W., Best, C. A., Dean, E. W., & Breuer, C. K. (2014) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2014.0123 · Cited by 165
“70,71 To improve the thrombogenic nature of PEUU, they blended or coated electrospun PEUU with copolymers featuring 2-methacry-loyloxyethyl phosphorylcholine (MPC), a material known to reduce platelet adhesion.”
InfluentialRational design of biodegradable thermoplastic polyurethanes for tissue repair
Xu, C., & Hong, Y. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.11.029 · Cited by 109
“In addition to physical blending and surface modification by nonthrombogenic moieties [175, 177], these nonthrombogenic moieties can be covalently incorporated into the PU backbone or grafted onto the polymer chain as pendants.”
BackgroundSelf-citationTakanari, K., Hong, Y., Hashizume, R., Huber, A., Amoroso, N. J., D'Amore, A., Badylak, S. F., & Wagner, W. R. (2016) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.1834 · Cited by 35
“…conventionally electrospun biodegradable, elastomeric poly(ester urethane)urea (PEUU) has strong mechanical properties with controllable degradation rates, but elicits a proinflammatory host response (Hong et al., 2008, 2009; Stankus et al., 2008; Hashizume et al., 2010; Soletti et al., 2011).”
BackgroundSelf-citation
Metadata
- Authors
- Soletti, L., Nieponice, A., Hong, Y., Ye, S., Stankus, J. J., Wagner, W. R., & Vorp, D. A.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2010-12-09
- Volume
- 96A
- Issue
- 2
- Pages
- 436-448
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1995013883
- Cited by
- 107
- References
- 2
- FWCI
- 5.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.