The permeability of silicone rubber to metal compounds: Relevance to implanted devices
The DOI matches its Crossref record.
Abstract
Most implanted electrical devices use encapsulant as insulation. The encapsulant may remain functional for many years, bonded to the metallic surfaces, but eventually become partly detached allowing corrosion to occur. To understand whether the corrosion products will cause toxic effects, we need to know how quickly they will permeate through the encapsulant. In these experiments, silicone capsules (the encapsulant) containing metal compounds were left in jars of initially pure water for 6 months, and the concentration of the metal in the water was measured. The amount of metal depended on the type of compound; for the organometallic compounds tested, permeation was very rapid. However, for most of the other compounds, whether oxides or salts, the amount of metal was below the control level and therefore could have been the result of contamination. These compounds were tin sulfate and oxide (<10 2), lead nitrate and oxide (<10 2), copper sulfate (<10 3), and nitrates of bismuth (<10 1), chrome (<10 2), nickel (<10 3) and zinc (<10 2). The numbers in brackets are the maximum mass (ng) of permeated metal after 6 months. Three silver compounds were tested but without proper controls; however, the amount of permeated silver appeared to be low: silver oxide (1.3 × 10 2), silver nitrate (6.3 × 10 1), and silver chloride (6 × 10 0). The resolution of this method is limited by contamination that is detected by control capsules. The conclusion is that compounds that are likely corrosion products permeate through silicone encapsulant at a low rate and seem unlikely to cause toxic effects. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part A, 2012.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Corrosion of silicon integrated circuits and lifetime predictions in implantable electronic devices
Vanhoestenberghe, A., & Donaldson, N. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/031002 · Cited by 140
Self-citationRen, H., Wu, J., Xi, C., Lehnert, N., Major, T., Bartlett, R. H., & Meyerhoff, M. E. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am406066a · Cited by 69
Lamont, C., Grego, T., Nanbakhsh, K., Shah Idil, A., Giagka, V, Vanhoestenberghe, A., Cogan, S., & Donaldson, N. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf0d6 · Cited by 28
Self-citationHöfler, L., Koley, D., Wu, J., Xi, C., & Meyerhoff, M. E. (2012) · RSC Advances · doi:10.1039/c2ra20853a · Cited by 20
Implantable Device Fabrication and Packaging
Stieglitz, T. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_102 · Cited by 7
Metadata
- Authors
- Donaldson, N., Baviskar, P., Cunningham, J., & Wilson, D.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2011-12-30
- Volume
- 100A
- Issue
- 3
- Pages
- 588-598
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2085011030
- Cited by
- 22
- References
- 0
- FWCI
- 2.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The permeability of silicone rubber to metal compounds: Relevance to implanted devices. https://app.cochat.ai/papers/10.1002/jbm.a.33257
- The paper
- Donaldson, N., Baviskar, P., Cunningham, J., & Wilson, D. (2012). The permeability of silicone rubber to metal compounds: Relevance to implanted devices. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.33257
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.