Cited by 69Nitric Oxide and Endothelin EffectsElectrochemical sensors and biosensorsPolymer Surface Interaction Studies

Electrochemically Modulated Nitric Oxide (NO) Releasing Biomedical Devices via Copper(II)-Tri(2-pyridylmethyl)amine Mediated Reduction of Nitrite

Open access
Ren, Hang, Wu, Jianfeng, Xi, Chuanwu, Lehnert, Nicolai, Major, Terry, Bartlett, Robert H., Meyerhoff, Mark E.·2014·ACS Applied Materials & Interfaces

Abstract

A controllable and inexpensive electrochemical nitric oxide (NO) release system is demonstrated to improve hemocompatibility and reduce bacterial biofilm formation on biomedical devices. Nitric oxide is produced from the electrochemical reduction of nitrite using a copper(II)-tri(2-pyridylmethyl)amine (Cu(II)TPMA) complex as a mediator, and the temporal profile of NO release can be modulated readily by applying different cathodic potentials. Single lumen and dual lumen silicone rubber catheters are employed as initial model biomedical devices incorporating this novel NO release approach. The modified catheters can release a steady, physiologically-relevant flux of NO for more than 7 days. Both single and dual lumen catheters with continuous NO release exhibit greatly reduced thrombus formation on their surfaces after short-term 7-h intravascular placement in rabbit veins (p < 0.02, n = 6). Three day in vitro antimicrobial experiments, in which the catheters are “turned on” for only 3 h of NO release each day, exhibit more than a 100-fold decrease in the amount of surface attached live bacteria (n = 5). These results suggest that this electrochemical NO generation system could provide a robust and highly effective new approach to improving the thromboresistance and antimicrobial properties of intravascular catheters and potentially other biomedical devices.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/am406066a

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Nitrite can generate NO via electrochemical reduction at an electrode surface using Cu(I) from Cu0 oxidation or Cu(II)-ligand complexes mimicking nitrite reductase.

    “Recently, it was demonstrated that nitrite can also be used to generate NO via electrochemical reduction at an electrode surface with either Cu(I) ion generated from oxidation of Cu0145,146 or via the use of Cu(II)-ligand complexes that mimic the active site of nitrite reductase (e.g., Cu(II)-tri(2-pyridylmethyl)amine, Cu(II)TPMA).147”
  • This electrochemical approach has been used to develop multi-lumen catheters with one lumen dedicated to generating NO electrochemically to reduce thrombus and microbial biofilm formation on catheter surfaces.

    “This approach has been utilized to develop a new generation of multi-lumen catheters in which one lumen is dedicated to generating NO electrochemically to reduce thrombus and microbial biofilm formation on the surface of the catheters.147,258”
  • NO releasing or generating polymers can have strong bactericidal effects, even for bacteria able to metabolize and deactivate NO, such as P. aeruginosa with NO reductase.

    “It has been clearly demonstrated that NO releasing/generating polymers can have strong bactericidal effects,19,146,147,162,201,227,283,284 even for bacteria that are able to metabolize and deactivate NO, such as P. aeruginosa, that possesses NO reductase enzyme that converts NO to nitrous oxide (N2O) and ultimately nitrogen (N2).86,201,219”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ren, H., Wu, J., Xi, C., Lehnert, N., Major, T., Bartlett, R. H., & Meyerhoff, M. E.
Affiliations
University of Michigan (US)
Corresponding author
Meyerhoff, Mark E.
Venue
ACS Applied Materials & Interfaces
Published
2014-03-10
Volume
6
Issue
6
Pages
3779-3783
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2317490821
Cited by
69
References
26
Citations by year
2026: 3 · 2025: 5 · 2024: 5 · 2023: 4 · 2022: 9 · 2021: 2 · 2020: 1 · 2019: 14 · 2018: 5 · 2017: 7 · 2016: 5 · 2015: 8 · 2014: 1
FWCI
4.65
Type
journal article
Language
en
Open access
Locations
  • ACS Applied Materials & Interfaces (publishedVersion, other-oa)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
NIH Office of the Director (EB-000783)
Topics
  • Health Sciences › Medicine › Physiology › Nitric Oxide and Endothelin Effects
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
Keywords
nitric oxide release, electrochemical mediator, intravascular catheters, hemocompatibility, thromboresistance, bacterial biofilm inhibition, antimicrobial surfaces, silicone rubber catheters, biomedical devices
MeSH terms
Animals, Bacteria, Copper, Humans, Nitric Oxide, Nitrites, Organometallic Compounds, Pyridines, Rabbits, Catheter-Related Infections, Vascular Access Devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review