CoChat

Investigating the role of substrate stiffness in the persistence of valvular interstitial cell activation

Open access
Quinlan, Angela M. Throm, Billiar, Kristen L. · 2012 · Journal of Biomedical Materials Research Part A
Cited by 117

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

During heart valve remodeling and in many disease states, valvular interstitial cells (VICs) shift to an activated myofibroblast phenotype characterized by enhanced synthetic and contractile activity. Pronounced alpha smooth muscle actin (αSMA)‐positive stress fibers, the hallmark of activated myofibroblasts, are also observed in VICs cultured on stiff substrates especially in the presence of transforming growth factor‐beta1 (TGF‐β1), however, the detailed relationship between stiffness and VIC phenotype has not been explored. The goal of this study was to characterize VIC activation as a function of substrate stiffness over a wide range of stiffness levels including that of diseased valves (stiff), normal valves (compliant), and hydrogels for heart valve tissue engineering (very soft). VICs obtained from porcine aortic valves were cultured on stiff tissue culture plastic to activate them, then, cultured on collagen‐coated polyacrylamide substrates of predefined stiffness in a high‐throughput culture system to assess the persistence of activation. Metrics extracted from regression analysis demonstrate that relative to a compliant substrate, stiff substrates result in higher cell numbers, more pronounced expression of αSMA‐positive stress fibers, and larger spread area which is in qualitative agreement with previous studies. Our data also indicate that VICs require a much lower substrate stiffness level to “deactivate” them than previously thought. The high sensitivity of VICs to substrate stiffness demonstrates the importance of the mechanical properties of materials used for valve repair or for engineering valve tissue. © 2012 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 100A: 2474–2482, 2012.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbm.a.34162

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Quinlan, A. M. T., & Billiar, K. L.
Venue
Journal of Biomedical Materials Research Part A
Publisher
Wiley
Published
2012-05-12
Volume
100A
Issue
9
Pages
2474-2482
ISSN
  • 1549-3296 (ISSN-L)
  • 1552-4965
OpenAlex
W2053721676
Cited by
117
References
2
FWCI
4.57
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.