Comparative analysis of in vitro oxidative degradation of poly(carbonate urethanes) for biostability screening
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The resistance to oxidation and environmental stress cracking of poly(carbonate urethanes) (PCUs) has generated significant interest as potential replacements of poly(ether urethanes) in medical devices. Several in vitro models have been developed to screen segmented polyurethanes for oxidative stability. High concentrations of reactive oxygen intermediates produced by combining hydrogen peroxide and dissolved cobalt ions has frequently been used to predict long‐term oxidative degradation with short‐term testing. Alternatively, a 3% H 2 O 2 concentration without metal ions is suggested within the ISO 10993‐13 standard to simulate physiological degradation rates. A comparative analysis which evaluates the predictive capabilities of each test method has yet to be completed. To this end, we have utilized both systems to test three commercially available PCUs with low and high soft segment content: Bionate® PCU and Bionate® II PCUs, two materials with different soft segment chemistries, and CarboSil® TSPCU, a thermoplastic silicone PCU. Bulk properties of all PCUs were retained with minor changes in molecular weight and tensile properties indicating surface oxidative degradation in the accelerated system after 36 days. Soft segment loss and surface damage were comparable to previous in vivo data. The 3% H 2 O 2 method exhibited virtually no changes on the surface or in bulk properties after 12 months of treatment despite previous in vivo results. These results indicate the accelerated test method more effectively characterized the oxidative degradation profiles than the 3% H 2 O 2 treatment system. The lack of bulk degradation in the 12‐month study also supports the hydrolytic stability of these PCUs. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 3649–3665, 2014.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“Exposure of PCUs to high concentrations of candidate enzymes has also been investigated due to the release of these enzymes from inflammatory cells at the implant site.(28,29) Although in vitro studies conducted on polyurethanes synthesized in-house raised concerns over the susceptibility of PCUs to enzymatic degradat…”
BackgroundThe Immunologic Release of Constituents from Neutrophil Leukocytes
Henson, P. M. (1971) · The Journal of Immunology · doi:10.4049/jimmunol.107.6.1535 · Cited by 347
Zhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318 · cited 1×
“Various concentrations of hydrogen peroxide have been explored with or without metal ions to provide an accelerated in vitro environment(9,34,42,43) that mimics the release of hydrogen peroxide, hydroxyl radicals, and superoxide anions by adherent macrophages and foreign body giant cells during frustrated phagocytosis…”
BackgroundChristenson, E. M., Anderson, J. M., & Hiltner, A. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30067 · Cited by 219 · cited 8×
“useful comparisons between the two.(18,52,53) The calculated soft segment loss of Bionate R 80A PCU after 36 days accelerated oxidation does not exceed the 12-month data point from previous in vivo data, but the results are far more significant than the 3% H2O2 system.”
BackgroundMethodResultInfluentialZhao, Q. H., McNally, A. K., Rubin, K. R., Renier, M., Wu, Y., Rose‐Caprara, V., Anderson, J. M., Hiltner, A., Urbanski, P., & Stokes, K. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270311 · Cited by 140
Hydrolytic degradation of poly(carbonate)-urethanes by monocyte-derived macrophages
Labow, R. S., Meek, E., & Santerre, J. P. (2001) · Biomaterials · doi:10.1016/s0142-9612(01)00049-7 · Cited by 108
Matheson, L. A., Labow, R. S., & Santerre, J. P. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10286 · Cited by 69
Antioxidant inhibition of poly(carbonate urethane) in vivo biodegradation
Christenson, E. M., Anderson, J. M., & Hiltner, A. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30506 · Cited by 64
In vivo biostability of polysiloxane polyether polyurethanes: Resistance to metal ion oxidation
Ward, B., Anderson, J., Ebert, M., McVenes, R., & Stokes, K. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30553 · Cited by 46
Cited by
On the biodegradability of polyethylene glycol, polypeptoids and poly(2-oxazoline)s
Ulbricht, J., Jordan, R., & Luxenhofer, R. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.02.029 · Cited by 348
Trucco, D., Vannozzi, L., Teblum, E., Telkhozhayeva, M., Nessim, G. D., Affatato, S., Al‐Haddad, H., Lisignoli, G., & Ricotti, L. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202001434 · Cited by 94
Liquid crystal elastomers as substrates for 3D, robust, implantable electronics
Maeng, J., Rihani, R. T., Javed, M., Rajput, J. S., Kim, H., Bouton, I. G., Criss, T. A., Pancrazio, J. J., Black, B. J., & Ware, T. H. (2020) · Journal of Materials Chemistry B · doi:10.1039/d0tb00471e · Cited by 31
Metadata
- Authors
- Dempsey, D. K., Carranza, C., Chawla, C. P., Gray, P., Eoh, J. H., Cereceres, S., & Cosgriff‐Hernandez, E. M.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2013-11-21
- Volume
- 102
- Issue
- 10
- Pages
- 3649-3665
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W1528232319
- Cited by
- 62
- References
- 9
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.