Protein/polysaccharide‐based scaffolds mimicking native extracellular matrix for cardiac tissue engineering applications
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Tissue engineering has emerged as a viable approach to treat disease or repair damage in tissues and organs. One of the key elements for the success of tissue engineering is the use of a scaffold serving as artificial extracellular matrix (ECM). The ECM hosts the cells and improves their survival, proliferation, and differentiation, enabling the formation of new tissue. Here, we propose the development of a class of protein/polysaccharide‐based porous scaffolds for use as ECM substitutes in cardiac tissue engineering. Scaffolds based on blends of a protein component, collagen or gelatin, with a polysaccharide component, alginate, were produced by freeze‐drying and subsequent ionic and chemical crosslinking. Their morphological, physicochemical, and mechanical properties were determined and compared with those of natural porcine myocardium. We demonstrated that our scaffolds possessed highly porous and interconnected structures, and the chemical homogeneity of the natural ECM was well reproduced in both types of scaffolds. Furthermore, the alginate/gelatin (AG) scaffolds better mimicked the native tissue in terms of interactions between components and protein secondary structure, and in terms of swelling behavior. The AG scaffolds also showed superior mechanical properties for the desired application and supported better adhesion, growth, and differentiation of myoblasts under static conditions. The AG scaffolds were subsequently used for culturing neonatal rat cardiomyocytes, where high viability of the resulting cardiac constructs was observed under dynamic flow culture in a microfluidic bioreactor. We therefore propose our protein/polysaccharide scaffolds as a viable ECM substitute for applications in cardiac tissue engineering. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 769–781, 2018.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exploring and Engineering the Cell Surface Interface
Stevens, M. M., & George, J. H. (2005) · Science · doi:10.1126/science.1106587 · Cited by 2,607
Accordion-like honeycombs for tissue engineering of cardiac anisotropy
Engelmayr, G. C., Cheng, M., Bettinger, C. J., Borenstein, J. T., Langer, R., & Freed, L. E. (2008) · Nature Materials · doi:10.1038/nmat2316 · Cited by 848
A liver-on-a-chip platform with bioprinted hepatic spheroids
Bhise, N. S., Manoharan, V., Massa, S., Tamayol, A., Ghaderi, M., Miscuglio, M., Lang, Q., Shrike Zhang, Y., Shin, S. R., Calzone, G., et al. (2016) · Biofabrication · doi:10.1088/1758-5090/8/1/014101 · Cited by 615
Self-citationTonsomboon, K., & Oyen, M. L. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2013.03.001 · Cited by 207
Cited by
Hydrogels: Properties and Applications in Biomedicine
Ho, T.-C., Chang, C.-C., Chan, H.-P., Chung, T.-W., Shu, C.-W., Chuang, K.-P., Duh, T.-H., Yang, M.-H., & Tyan, Y.-C. (2022) · Molecules · doi:10.3390/molecules27092902 · Cited by 1,091
Novel Biomedical Applications of Crosslinked Collagen
Gu, L., Shan, T., Ma, Y.-X., Tay, F. R., & Niu, L. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.10.007 · Cited by 305
Chitosan and hyaluronic-based hydrogels could promote the infected wound healing
Bai, Q., Gao, Q., Hu, F., Zheng, C., Chen, W., Sun, N., Liu, J., Zhang, Y., Wu, X., & Lu, T. (2023) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2023.123271 · Cited by 125
Self-citationAdvancements in tissue engineering for cardiovascular health: a biomedical engineering perspective
Razavi, Z.-S., Soltani, M., Mahmoudvand, G., Farokhi, S., Karimi-Rouzbahani, A., Farasati-Far, B., Tahmasebi-Ghorabi, S., Pazoki-Toroudi, H., & Afkhami, H. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1385124 · Cited by 64
Banerjee, S., Szepes, M., Dibbert, N., Rios-Camacho, J.-C., Kirschning, A., Gruh, I., & Dräger, G. (2021) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2021.117924 · Cited by 25
Metadata
- Authors
- Rosellini, E., Zhang, Y. S., Migliori, B., Barbani, N., Lazzeri, L., Shin, S. R., Dokmeci, M. R., & Cascone, M. G.
- Venue
- Journal of Biomedical Materials Research Part A
- Publisher
- Wiley
- Published
- 2017-11-20
- Volume
- 106
- Issue
- 3
- Pages
- 769-781
- ISSN
- 1549-3296 (ISSN-L)
- 1552-4965
- OpenAlex
- W2766720830
- Cited by
- 117
- References
- 4
- FWCI
- 7.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Protein/polysaccharide‐based scaffolds mimicking native extracellular matrix for cardiac tissue engineering applications. https://app.cochat.ai/papers/10.1002/jbm.a.36272
- The paper
- Rosellini, E., Zhang, Y. S., Migliori, B., Barbani, N., Lazzeri, L., Shin, S. R., Dokmeci, M. R., & Cascone, M. G. (2018). Protein/polysaccharide‐based scaffolds mimicking native extracellular matrix for cardiac tissue engineering applications. Journal of Biomedical Materials Research Part A. https://doi.org/10.1002/jbm.a.36272
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.