The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Characterization of parylene C as an encapsulation material for implanted neural prostheses
Abstract
The applicability of parylene C as an encapsulation material for implanted neural prostheses was characterized and optimized. The adhesion of parylene C was tested on different substrate materials, which were commonly used in neural prostheses and the efficiency of different adhesion promotion methods was investigated. On Si 3 N 4, platinum, and on a first film of parylene C, a satisfactory adhesion was achieved with Silane A‐174, which even withstood standard steam sterilization. The adhesion to gold and polyimide could not be improved sufficiently with the tested methods. Furthermore, tensile tests and measurements of the degree of crystallinity were performed on untreated, on steam sterilized, and on annealed parylene C layers to investigate the influence of thermal treatment. This led to more brittle and stiffer films due to an increase in the crystalline portion in the parylene layers. Finally, an electrochemical impedance spectroscopy was used to test if a parylene C layer was able to protect a metallic structure against corrosion on a Si 3 N 4 substrate. The results indicated that this could be only possible by treating the substrate with Silane A‐174. To receive parylene C layers with a good encapsulation performance, it is important to consider the materials, which are used in the neural prosthesis, to find the best suited process parameters. © 2010 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2010
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
A New, General Synthetic Method for the Preparation of Linear Poly‐p‐xylylenes
Gorham, W. F. (1966) · Journal of Polymer Science Part A-1: Polymer Chemistry · doi:10.1002/pol.1966.150041209 · Cited by 666
Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
Rousche, P. J., & Normann, R. A. (1998) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(98)00031-4 · Cited by 646
Neural probe design for reduced tissue encapsulation in CNS
Seymour, J. P., & Kipke, D. R. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.024 · Cited by 462
Disinfection and Sterilization in Health Care Facilities: What Clinicians Need to Know
Rutala, W. A., & Weber, D. J. (2004) · Clinical Infectious Diseases · doi:10.1086/423182 · Cited by 399
Parylene flexible neural probes integrated with microfluidic channels
Takeuchi, S., Ziegler, D., Yoshida, Y., Mabuchi, K., & Suzuki, T. (2005) · Lab on a Chip · doi:10.1039/b417497f · Cited by 364
RODGER, D., FONG, A., LI, W., AMERI, H., AHUJA, A., GUTIERREZ, C., LAVROV, I., ZHONG, H., MENON, P., & MENG, E. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.10.069 · Cited by 325
Sacral anterior root stimulators for bladder control in paraplegia
Brindley, G. S., Polkey, C. E., & Rushton, D. N. (1982) · Spinal Cord · doi:10.1038/sc.1982.65 · Cited by 311
Parylene as a Chronically Stable, Reproducible Microelectrode Insulator
Loeb, G. E., Bak, M. J., Salcman, M., & Schmidt, E. M. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326115 · Cited by 258
MED-EL Cochlear Implants: State of the Art and a Glimpse Into the Future
Hochmair, I., Nopp, P., Jolly, C., Schmidt, M., Schößer, H., Garnham, C., & Anderson, I. (2006) · Trends in Amplification · doi:10.1177/1084713806296720 · Cited by 254
Cited by
Polymeric Biomaterials for Medical Implants and Devices
Teo, A. J. T., Mishra, A., Park, I., Kim, Y.-J., Park, W.-T., & Yoon, Y.-J. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00429 · Cited by 778
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Flexible Organic Electronics in Biology: Materials and Devices
Liao, C., Zhang, M., Yao, M. Y., Hua, T., Li, L., & Yan, F. (2015) · Advanced Materials · doi:10.1002/adma.201402625 · Cited by 438
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
Metadata
- Authors
- Hassler, C., von Metzen, R. P., Ruther, P., & Stieglitz, T.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2010-01-29
- Volume
- 93B
- Issue
- 1
- Pages
- 266-274
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2067692467
- Cited by
- 264
- References
- 29
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of parylene C as an encapsulation material for implanted neural prostheses. https://app.cochat.ai/papers/10.1002/jbm.b.31584
- The paper
- Hassler, C., von Metzen, R. P., Ruther, P., & Stieglitz, T. (2010). Characterization of parylene C as an encapsulation material for implanted neural prostheses. Journal of Biomedical Materials Research Part B: Applied Biomaterials. https://doi.org/10.1002/jbm.b.31584
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.