Plate‐shape carbonated hydroxyapatite/collagen nanocomposite hydrogel via in situ mineralization of hydroxyapatite concurrent with gelation of collagen at pH = 7.4 and 37°C
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The objective of this study was to develop a collagen/hydroxyapatite (HA) nanocomposite scaffold for bone tissue engineering applications. For this purpose, in situ mineralization of HA was accompanied with formation of collagen hydrogel at condition similar to the physiological condition, pH = 7.4, and 37°C. The physicochemical and biological properties of the in situ scaffold were compared with nanocomposite fabricated by mixing HA powder and collagen hydrogel (powder‐mixed scaffold). The HA in this method was formed in the same condition as the in situ method. X‐ray diffraction and FTIR analysis of in situ scaffold showed the formation of carbonated HA, similar to bone, while the HA powder in powder‐mixed scaffold showed non‐carbonated structure. Scanning electron microscopy revealed the formation of fibrillated collagen in both composites. HA was observed in both scaffolds, but with different morphology. The in situ formed HA had a plate‐like morphology while the preformed HA showed spherical morphology in the powder‐mixed scaffold. The in‐vitro cytocompatibility and osteogenesis activity of scaffolds using osteoblast‐like cells (MG‐63) showed higher cytocompatibility and more osteogenesis capability of the in situ scaffold in comparison with the powder‐mixed scaffold. The results suggest the in situ method as a proper approach for fabrication of HA/collagen scaffolds with similar properties like bone. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1920–1929, 2019.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biocomposites containing natural polymers and hydroxyapatite for bone tissue engineering
Swetha, M., Sahithi, K., Moorthi, A., Srinivasan, N., Ramasamy, K., & Selvamurugan, N. (2010) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2010.03.015 · Cited by 548
Hierarchically biomimetic bone scaffold materials: nano‐HA/collagen/PLA composite
Liao, S. S., Cui, F. Z., Zhang, W., & Feng, Q. L. (2004) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.20035 · Cited by 487
Shen, X., Chen, L., Cai, X., Tong, T., Tong, H., & Hu, J. (2011) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-010-4199-x · Cited by 61
Zheng, L., Jiang, X., Chen, X., Fan, H., & Zhang, X. (2014) · Biomedical Materials · doi:10.1088/1748-6041/9/6/065004 · Cited by 59
Cited by
Amirrah, I. N., Lokanathan, Y., Zulkiflee, I., Wee, M. F. M. R., Motta, A., & Fauzi, M. B. (2022) · Biomedicines · doi:10.3390/biomedicines10092307 · Cited by 426
“The swelling ratio of pure collagen is approximately 650% due to the presence of hydrophilic groups [194].”
BackgroundCollagen-based biomaterials for bone tissue engineering
Li, Y., Liu, Y., Li, R., Bai, H., Zhu, Z., Zhu, L., Zhu, C., Che, Z., Liu, H., Wang, J., et al. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.110049 · Cited by 275
Current Insights into Collagen Type I
Naomi, R., Ridzuan, P. M., & Bahari, H. (2021) · Polymers · doi:10.3390/polym13162642 · Cited by 254
New perspectives: In-situ tissue engineering for bone repair scaffold
Cao, S., Zhao, Y., Hu, Y., Zou, L., & Chen, J. (2020) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2020.108445 · Cited by 169
Gharati, G., Shirian, S., Sharifi, S., Mirzaei, E., Bakhtirimoghadam, B., Karimi, I., & Nazari, H. (2022) · Biological Trace Element Research · doi:10.1007/s12011-021-02909-6 · Cited by 19
Self-citation
Metadata
- Authors
- Takallu, S., Mirzaei, E., Azadi, A., Karimizade, A., & Tavakol, S.
- Venue
- Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Publisher
- Wiley
- Published
- 2018-11-22
- Volume
- 107
- Issue
- 6
- Pages
- 1920-1929
- ISSN
- 1552-4973 (ISSN-L)
- 1552-4981
- OpenAlex
- W2901334632
- Cited by
- 44
- References
- 4
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.