A multinational study to develop universal standardization of whole-body bone density and composition using GE Healthcare Lunar and Hologic DXA systems
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Dual-energy x-ray absorptiometry (DXA) is used to assess bone mineral density (BMD) and body composition, but measurements vary among instruments from different manufacturers. We sought to develop cross-calibration equations for whole-body bone density and composition derived using GE Healthcare Lunar and Hologic DXA systems. This multinational study recruited 199 adult and pediatric participants from a site in the US (n = 40, ages 6 through 16 years) and one in China (n = 159, ages 5 through 81 years). The mean age of the participants was 44.2 years. Each participant was scanned on both GE Healthcare Lunar and Hologic Discovery or Delphi DXA systems on the same day (US) or within 1 week (China) and all scans were centrally analyzed by a single technologist using GE Healthcare Lunar Encore version 14.0 and Hologic Apex version 3.0. Paired t-tests were used to test the results differences between the systems. Multiple regression and Deming regressions were used to derive the cross-conversion equations between the GE Healthcare Lunar and Hologic whole-body scans. Bone and soft tissue measures were highly correlated between the GE Healthcare Lunar and Hologic and systems, with r ranging from 0.96 percent fat [PFAT] to 0.98 (BMC). Significant differences were found between the two systems, with average absolute differences for PFAT, BMC, and BMD of 1.4%, 176.8 g and 0.013 g/cm2, respectively. After cross-calibration, no significant differences remained between GE Healthcare Lunar measured results and the results converted from Hologic. The equations we derived reduce differences between BMD and body composition as determined by GE Healthcare Lunar and Hologic systems and will facilitate combining study results in clinical or epidemiological studies. © 2012 American Society for Bone and Mineral Research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 1×
“Bland-Altman statistics((13)) were used to test the agreement with the resubstitution validation.”
MethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Cited by
Sarcopenia Definition: The Position Statements of the Sarcopenia Definition and Outcomes Consortium
Bhasin, S., Travison, T. G., Manini, T. M., Patel, S., Pencina, K. M., Fielding, R. A., Magaziner, J. M., Newman, A. B., Kiel, D. P., Cooper, C., et al. (2020) · Journal of the American Geriatrics Society · doi:10.1111/jgs.16372 · Cited by 723
Crabtree, N. J., Arabi, A., Bachrach, L. K., Fewtrell, M., El-Hajj Fuleihan, G., Kecskemethy, H. H., Jaworski, M., & Gordon, C. M. (2014) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2014.01.003 · Cited by 552
Obesity, adiposity, and dyslipidemia: a consensus statement from the National Lipid Association
Bays, H. E., Toth, P. P., Kris-Etherton, P. M., Abate, N., Aronne, L. J., Brown, W. V., Gonzalez-Campoy, J. M., Jones, S. R., Kumar, R., La Forge, R., et al. (2013) · Journal of Clinical Lipidology · doi:10.1016/j.jacl.2013.04.001 · Cited by 521
Shepherd, J. A., Ng, B. K., Sommer, M. J., & Heymsfield, S. B. (2017) · Bone · doi:10.1016/j.bone.2017.06.010 · Cited by 460
Self-citationSuetta, C., Haddock, B., Alcazar, J., Noerst, T., Hansen, O. M., Ludvig, H., Kamper, R. S., Schnohr, P., Prescott, E., Andersen, L. L., et al. (2019) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12477 · Cited by 293
Veronese, N., Berton, L., Carraro, S., Bolzetta, F., De Rui, M., Perissinotto, E., Toffanello, E. D., Bano, G., Pizzato, S., Miotto, F., et al. (2014) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.113.080168 · Cited by 154
“Body composition was assessed by dual-energy X-ray absorptiometry with a fan-beam technology (Hologic Discovery A) (21).”
MethodCawthon, P. M., Travison, T. G., Manini, T. M., Patel, S., Pencina, K. M., Fielding, R. A., Magaziner, J. M., Newman, A. B., Brown, T., Kiel, D. P., et al. (2020) · The Journals of Gerontology Series A · doi:10.1093/gerona/glz081 · Cited by 127
“Therefore, DXA-derived estimates of lean and fat mass were harmonized across the eligible epidemiological cohorts using mathematical equations provided by scientific group at Hologic, Inc (37).”
MethodFour men in a boat: Ultra-endurance exercise alters the gut microbiome
Keohane, D. M., Woods, T., O’Connor, P., Underwood, S., Cronin, O., Whiston, R., O'Sullivan, O., Cotter, P., Shanahan, F., & Molloy, M. G. M. (2019) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2019.04.004 · Cited by 113
Imboden, M. T., Swartz, A. M., Finch, H. W., Harber, M. P., & Kaminsky, L. A. (2017) · PLOS ONE · doi:10.1371/journal.pone.0176161 · Cited by 75
“The only other known reference values for these LM variables measured directly from DXA were derived from the 1999–2004 NHANES dataset [12], which used the Hologic QDR 4500A system that is known to differ from GE-Healthcare systems [15], as well as in reference datasets from Mexican [19] and Australian [7] adult popul…”
BackgroundMethodInfluentialSon, J. W., Han, B., Bennett, J. P., Heymsfield, S., & Lim, S. (2025) · Obesity Reviews · doi:10.1111/obr.13844 · Cited by 74
Scafoglieri, A., Clarys, J. P., Bauer, J. M., Verlaan, S., Van Malderen, L., Vantieghem, S., Cederholm, T., Sieber, C. C., Mets, T., & Bautmans, I. (2017) · Clinical Nutrition · doi:10.1016/j.clnu.2016.04.026 · Cited by 65
“In attempts to accommodate for these problems in clinical settings and epidemiological studies, regional conversion formulas have been proposed recently and NHANES reference curves applicable to DXAwhole body scans acquired on GE Lunar systems have been presented [10,11].”
BackgroundAre men at greater risk of lean mass deficits in rheumatoid arthritis?
Baker, J. F., Long, J., Ibrahim, S., Leonard, M. B., & Katz, P. (2015) · Arthritis Care & Research · doi:10.1002/acr.22396 · Cited by 44
“In addition, DXA results from UCSF subjects were analyzed using earlier versions of the Lunar Prodigy software than the versions used in the adjustment published by Shepherd et al (22).”
MethodSylivris, A., Mesinovic, J., Scott, D., & Jansons, P. (2022) · Obesity Reviews · doi:10.1111/obr.13442 · Cited by 39
Gutiérrez-Marín, D., Luque, V., Ferré, N., Fewtrell, M. S., Williams, J. E., & Wells, J. C. K. (2019) · European Journal of Clinical Nutrition · doi:10.1038/s41430-019-0447-4 · Cited by 26
Metadata
- Authors
- Shepherd, J. A., Fan, B., Lu, Y., Wu, X. P., Wacker, W. K., Ergun, D. L., & Levine, M. A.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-05-23
- Volume
- 27
- Issue
- 10
- Pages
- 2208-2216
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2034147766
- Cited by
- 218
- References
- 2
- FWCI
- 9.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.