Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 204

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Vitamin D Storage in Adipose Tissue of Obese and Normal Weight Women

Open access
Carrelli, Angela, Bucovsky, Mariana, Horst, Ronald, Cremers, Serge, Zhang, Chengchen, Bessler, Marc, Schrope, Beth, Evanko, John, Blanco, Jody, Silverberg, Shonni J, Stein, Emily M · 2017 · Journal of Bone and Mineral Research

Abstract

Although vitamin D deficiency is prevalent among obese individuals, its cause is poorly understood. Few studies have measured vitamin D concentrations in adipose of obese (OB) subjects, and none have included normal weight controls (C). The goal of this study was to investigate whether the relationship between body composition, serum 25-hydroxyvitamin D (25OHD), vitamin D in subcutaneous (SQ) and omental (OM) adipose, and total adipose stores of vitamin D differ among OB and C. Obese women undergoing bariatric surgery and normal-weight women undergoing abdominal surgery for benign gynecologic conditions were enrolled. Subjects had measurements of serum 25OHD by high-performance liquid chromatography (HPLC) and body composition by dual-energy X-ray absorptiometry (DXA). Vitamin D concentrations in SQ and OM adipose were measured by mass spectroscopy. Thirty-six women were enrolled. Serum 25OHD was similar between groups (OB 27 ± 2 versus C 26 ± 2 ng/mL; p = 0.71). Adipose vitamin D concentrations were not significantly different in either SQ (OB 34 ± 9 versus C 26 ± 12 ng/g; p = 0.63) or OM compartments (OB 51 ± 13 versus C 30 ± 18 ng/g; p = 0.37). The distribution of vitamin D between SQ and OM compartments was similar between groups. Serum 25OHD was directly related to adipose vitamin D in both groups. Total body vitamin D stores were significantly greater in OB than in C (2.3 ± 0.6 versus 0.4 ± 0.8 mg, respectively; p < 0.01). In summary, although OB had significantly greater total vitamin D stores than C, the relationship between serum 25OHD and fat vitamin D and the overall pattern of distribution of vitamin D between the OM and SQ fat compartments was similar. Our data demonstrate that obese subjects have greater adipose stores of vitamin D. They support the hypotheses that the enlarged adipose mass in obese individuals serves as a reservoir for vitamin D and that the increased amount of vitamin D required to saturate this depot may predispose obese individuals to inadequate serum 25OHD. © 2016 American Society for Bone and Mineral Research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jbmr.2979

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 204

Metadata

Authors
Carrelli, A., Bucovsky, M., Horst, R., Cremers, S., Zhang, C., Bessler, M., Schrope, B., Evanko, J., Blanco, J., Silverberg, S. J., & Stein, E. M.
Venue
Journal of Bone and Mineral Research
Published
2016-08-20
Volume
32
Issue
2
Pages
237-242
ISSN
  • 0884-0431 (ISSN-L)
  • 1523-4681
OpenAlex
W2517989310
Cited by
204
References
4
FWCI
10.94
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.