The effect of impact direction on the structural capacity of the proximal femur during falls
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
As with any structure, the structural capacity of the proximal femur depends on the applied loads and these can vary as a function of impact direction during a fall. However, despite its potential importance in hip fracture risk assessment, the relative importance of impact direction is unknown. To investigate the role of impact direction in hip fracture, we developed a detailed finite element model of the proximal femur. We analyzed four loading configurations that represent a range of possible falls on the greater trochanter. Our results indicate that a change in the angle between the line of action of the applied force and the axis of the femoral neck from 0° (representing a direct lateral impact) to 45° (representing a posterolateral impact) reduced structural capacity by 26%. This weakening of the femur with changes in impact direction is comparable to the weakening associated with 2–3 decades of age-related bone loss. Our result elucidates the independent contribution of fall mechanics to hip fracture risk by identifying an aspect of the fall (the direction of impact) that is an important determinant of fall severity. The results can also be incorporated into a refined clinical method for assessment of hip fracture risk that accounts for the complex interactions between fall severity and bone fragility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The elastic and ultimate properties of compact bone tissue
Reilly, D. T., & Burstein, A. H. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90075-5 · Cited by 1,533
Changes in Bone Mineral Density of the Proximal Femur and Spine with Aging
Riggs, B. L., Wahner, H. W., Seeman, E., Offord, K. P., Dunn, W. L., Mazess, R. B., Johnson, K. A., & Melton, L. J. (1982) · Journal of Clinical Investigation · doi:10.1172/jci110667 · Cited by 816
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401
Keaveny, T. M., Wachtel, E. F., Ford, C. M., & Hayes, W. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90054-x · Cited by 330
Self-citationAge-related reductions in the strength of the femur tested in a fall-loading configuration.
Courtney, A. C., Wachtel, E. F., Myers, E. R., & Hayes, W. C. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199503000-00008 · Cited by 301
Self-citation
Cited by
Parkkari, J., Kannus, P., Palvanen, M., Natri, A., Vainio, J., Aho, H., Vuori, I., & Järvinen, M. (1999) · Calcified Tissue International · doi:10.1007/s002239900679 · Cited by 563
Modelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504
“[126] analyzed the effect of internal/external rotations on femoral strength for loading that represented impact from a fall onto the hip.”
BackgroundMethodFemoral strength is better predicted by finite element models than QCT and DXA
Cody, D. D., Gross, G. J., J. Hou, F., Spencer, H. J., Goldstein, S. A., & P. Fyhrie, D. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00099-8 · Cited by 440
Schileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 373
Taddei, F., Schileo, E., Helgason, B., Cristofolini, L., & Viceconti, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.10.014 · Cited by 339
Subject-specific finite element models can accurately predict strain levels in long bones
Schileo, E., Taddei, F., Malandrino, A., Cristofolini, L., & Viceconti, M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.02.010 · Cited by 330
Improved prediction of proximal femoral fracture load using nonlinear finite element models
Keyak, J. H. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00045-5 · Cited by 314
Kaptoge, S., Beck, T. J., Reeve, J., Stone, K. L., Hillier, T. A., Cauley, J. A., & Cummings, S. R. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080802 · Cited by 283
Keyak, J. H., & Falkinstein, Y. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00081-x · Cited by 259
Keaveny, T. M., Donley, D. W., Hoffmann, P. F., Mitlak, B. H., Glass, E. V., & San Martin, J. A. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.061011 · Cited by 258
Self-citationCrabtree, N., Loveridge, N., Parker, M., Rushton, N., Power, J., Bell, K. L., Beck, T. J., & Reeve, J. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.7.1318 · Cited by 166
Mechanical behavior of human trabecular bone after overloading
Keaveny, T. M., Wachtel, E. F., & Kopperdahl, D. L. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170308 · Cited by 155
Self-citationGoda, I., & Ganghoffer, J.-F. (2015) · International Journal of Engineering Science · doi:10.1016/j.ijengsci.2014.10.007 · Cited by 51
Development and Validation of a Predictive Bone Fracture Risk Model for Astronauts
Nelson, E. S., Lewandowski, B., Licata, A., & Myers, J. G. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9779-x · Cited by 50
Metadata
- Authors
- Ford, C. M., Keaveny, T. M., & Hayes, W. C.
- Venue
- Journal of Bone and Mineral Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-03-01
- Volume
- 11
- Issue
- 3
- Pages
- 377-383
- ISSN
- 0884-0431 (ISSN-L)
- 1523-4681
- OpenAlex
- W2125144043
- Cited by
- 157
- References
- 5
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.