CoChat

Inpatient glucose control: a glycemic survey of 126 U.S. hospitals

Open access
Cook, Curtiss B., Kongable, Gail L., Potter, Daniel Jason, Abad, Victor J., Leija, Dora E., Anderson, Marcy · 2009 · Journal of Hospital Medicine
Cited by 213

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Despite increased awareness of the value of treating inpatient hyperglycemia, little is known about glucose control in U.S. hospitals. METHODS: The Remote Automated Laboratory System‐Plus (RALS®‐Plus Medical Automation Systems, Charlottesville, VA) was used to extract inpatient point‐of‐care bedside glucose (POC‐BG) tests from 126 hospitals for the period January to December 2007. Patient‐day‐weighted mean POC‐BG and hypoglycemia/hyperglycemia rates were calculated for intensive care unit (ICU) and non‐ICU areas. The relationship of POC‐BG levels with hospital characteristics was determined. RESULTS: A total of 12,559,305 POC‐BG measurements were analyzed: 2,935,167 from the ICU and 9,624,138 from the non‐ICU. Patient‐day‐weighted mean POC‐BG was 165 mg/dL for ICU and 166 mg/dL for non‐ICU. Hospital hyperglycemia (>180 mg/dL) prevalence was 46.0% for ICU and 31.7% for non‐ICU. Hospital hypoglycemia (<70 mg/dL) prevalence was low at 10.1% for ICU and 3.5% for non‐ICU. For ICU and non‐ICU there was a significant relationship between number of beds and patient‐day‐weighted mean POC‐BG levels, with larger hospitals (≥400 beds) having lower patient‐day weighted mean POC‐BG per patient day than smaller hospitals (<200 beds, P < 0.001). Rural hospitals had higher POC‐BG levels compared to urban and academic hospitals (P < 0.05), and hospitals in the West had the lowest values. CONCLUSIONS: POC‐BG data captured through automated data management software can support hospital efforts to monitor the status of inpatient glycemic control. From these data, hospital hyperglycemia is common, hypoglycemia prevalence is low, and POC‐BG levels vary by hospital characteristics. Increased hospital participation in data collection and reporting may facilitate the creation of a national benchmarking process for the development of best practices and improved inpatient hyperglycemia management. Journal of Hospital Medicine 2009;4:E7–E17. © 2009 Society of Hospital Medicine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jhm.533

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 213

Metadata

Authors
Cook, C. B., Kongable, G. L., Potter, D. J., Abad, V. J., Leija, D. E., & Anderson, M.
Venue
Journal of Hospital Medicine
Publisher
Wiley
Published
2009-11
Volume
4
Issue
9
Pages
E7-E14
ISSN
  • 1553-5592 (ISSN-L)
  • 1553-5606
OpenAlex
W2018751432
Cited by
213
References
9
FWCI
5.87
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inpatient glucose control: a glycemic survey of 126 U.S. hospitals. https://app.cochat.ai/papers/10.1002/jhm.533
The paper
Cook, C. B., Kongable, G. L., Potter, D. J., Abad, V. J., Leija, D. E., & Anderson, M. (2009). Inpatient glucose control: a glycemic survey of 126 U.S. hospitals. Journal of Hospital Medicine. https://doi.org/10.1002/jhm.533

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.