CoChat

On the synchronization of transcranial magnetic stimulation and functional echo‐planar imaging

Open access
Bestmann, Sven, Baudewig, Jürgen, Frahm, Jens · 2003 · Journal of Magnetic Resonance Imaging
Cited by 83

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Purpose: To minimize artifacts in echo‐planar imaging (EPI) of human brain function introduced by simultaneous transcranial magnetic stimulation (TMS). Materials and Methods: Distortions due to TMS pulses (0.25 msec, 2.0 T) were studied at 2.0 T before and during EPI. Results: Best results were obtained if both the EPI section orientation and the frequency‐encoding gradient were parallel to the plane of the TMS coil. Under these conditions, a TMS pulse caused image distortions when preceding the EPI sequence by less than 100 msec. Recordings with a magnetic field gradient pick‐up coil revealed transient magnetic fields after TMS, which are generated by eddy currents in the TMS coil. TMS during image acquisition completely spoiled all transverse magnetizations and induced disturbances ranging from image corruption to mild image blurring, depending on the affected low and high spatial frequencies. Simultaneous TMS and radio‐frequency (RF) excitation gave rise to T1‐dependent signal changes that lasted for several seconds and yielded pronounced false‐positive activations during functional brain mapping. Conclusion: To ensure reliable and robust combinations, TMS should be applied at least 100 msec before EPI while completely avoiding any pulses during imaging. J. Magn. Reson. Imaging 2003;17:309–316. © 2003 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.10260

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 83

Metadata

Authors
Bestmann, S., Baudewig, J., & Frahm, J.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2003-02-19
Volume
17
Issue
3
Pages
309-316
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2156288014
Cited by
83
References
2
FWCI
3.62
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On the synchronization of transcranial magnetic stimulation and functional echo‐planar imaging. https://app.cochat.ai/papers/10.1002/jmri.10260
The paper
Bestmann, S., Baudewig, J., & Frahm, J. (2003). On the synchronization of transcranial magnetic stimulation and functional echo‐planar imaging. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10260

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.