On the synchronization of transcranial magnetic stimulation and functional echo‐planar imaging
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose: To minimize artifacts in echo‐planar imaging (EPI) of human brain function introduced by simultaneous transcranial magnetic stimulation (TMS). Materials and Methods: Distortions due to TMS pulses (0.25 msec, 2.0 T) were studied at 2.0 T before and during EPI. Results: Best results were obtained if both the EPI section orientation and the frequency‐encoding gradient were parallel to the plane of the TMS coil. Under these conditions, a TMS pulse caused image distortions when preceding the EPI sequence by less than 100 msec. Recordings with a magnetic field gradient pick‐up coil revealed transient magnetic fields after TMS, which are generated by eddy currents in the TMS coil. TMS during image acquisition completely spoiled all transverse magnetizations and induced disturbances ranging from image corruption to mild image blurring, depending on the affected low and high spatial frequencies. Simultaneous TMS and radio‐frequency (RF) excitation gave rise to T1‐dependent signal changes that lasted for several seconds and yielded pronounced false‐positive activations during functional brain mapping. Conclusion: To ensure reliable and robust combinations, TMS should be applied at least 100 msec before EPI while completely avoiding any pulses during imaging. J. Magn. Reson. Imaging 2003;17:309–316. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pascual-Leone, A. (2000) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(00)00081-7 · Cited by 923 · cited 1×
“, in terms of blood oxygenation level dependent (BOLD) MRI responses, the approach is expected to contribute new insights into the functional connectivity of the human brain, its “functional” plasticity using the concept of virtual lesions (8), and TMSinducable neuronal plasticity.”
Echoplanar BOLD fMRI of brain activation induced by concurrent transcranial magnetic stimulation
BOHNING, D. E., SHASTRI, A., NAHAS, Z., LORBERBAUM, J. P., ANDERSEN, S. W., DANNELS, W. R., HAXTHAUSEN, E.-U., VINCENT, D. J., & GEORGE, M. S. (1998) · Investigative Radiology · doi:10.1097/00004424-199806000-00004 · Cited by 210
Cited by
Noninvasive Human Brain Stimulation
Wagner, T., Valero-Cabre, A., & Pascual-Leone, A. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.061206.133100 · Cited by 873
Study design in fMRI: Basic principles
Amaro, E., & Barker, G. J. (2006) · Brain and Cognition · doi:10.1016/j.bandc.2005.11.009 · Cited by 517
Concurrent TMS-fMRI and Psychophysics Reveal Frontal Influences on Human Retinotopic Visual Cortex
Ruff, C. C., Blankenburg, F., Bjoertomt, O., Bestmann, S., Freeman, E., Haynes, J.-D., Rees, G., Josephs, O., Deichmann, R., & Driver, J. (2006) · Current Biology · doi:10.1016/j.cub.2006.06.057 · Cited by 514
Self-citationBestmann, S., Baudewig, J., Siebner, H. R., Rothwell, J. C., & Frahm, J. (2004) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2004.03277.x · Cited by 455
Self-citationEffects of transcranial direct current stimulation (tDCS) on human regional cerebral blood flow
Zheng, X., Alsop, D. C., & Schlaug, G. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.06.018 · Cited by 368
Consensus paper: Combining transcranial stimulation with neuroimaging
Siebner, H. R., Bergmann, T. O., Bestmann, S., Massimini, M., Johansen-Berg, H., Mochizuki, H., Bohning, D. E., Boorman, E. D., Groppa, S., Miniussi, C., et al. (2009) · Brain Stimulation · doi:10.1016/j.brs.2008.11.002 · Cited by 356
Self-citationSparing, R., Buelte, D., Meister, I. G., Pauš, T., & Fink, G. R. (2008) · Human Brain Mapping · doi:10.1002/hbm.20360 · Cited by 322
Negative BOLD differentiates visual imagery and perception
Amedi, A., Malach, R., & Pascual-Leone, A. (2005) · Neuron · doi:10.1016/j.neuron.2005.10.032 · Cited by 271
BOLD MRI responses to repetitive TMS over human dorsal premotor cortex
Bestmann, S., Baudewig, J., Siebner, H. R., Rothwell, J. C., & Frahm, J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.05.027 · Cited by 271
Self-citationBestmann, S., Baudewig, J., Siebner, H. R., Rothwell, J. C., & Frahm, J. (2003) · NeuroImage · doi:10.1016/j.neuroimage.2003.07.028 · Cited by 262
Self-citationHanlon, C. A., Canterberry, M., Taylor, J. J., DeVries, W., Li, X., Brown, T. R., & George, M. S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0067917 · Cited by 80
“A number of prior studies have examined the association between a single-pulse of TMS over the motor cortex [24,27,29,40,43] or DLPFC [32,33,34] and a BOLD signal response in both the region being stimulated and its subcortical targets.”
BackgroundHanlon, C. A., Dowdle, L. T., Moss, H., Canterberry, M., & George, M. S. (2016) · Neuropsychopharmacology · doi:10.1038/npp.2016.114 · Cited by 76
“…signal in the cortex directly affected by the induced electrical field (MPFC and DLPFC), as well as areas monosynaptically connected to the site (Baudewig et al, 2001; Bestmann et al, 2003; Bestmann et al, 2005; Bohning et al, 1999; Bohning et al, 2000a; Bohning et al, 1998; Bohning et al, 2000b).”
BackgroundConcurrent TMS-fMRI reveals interactions between dorsal and ventral attentional systems
Leitao, J., Thielscher, A., Tunnerhoff, J., & Noppeney, U. (2015) · Journal of Neuroscience · doi:10.1523/jneurosci.0939-15.2015 · Cited by 58
“Each gap was introduced to allow the delivery of four TMS pulses without interference with image quality (Bestmann et al., 2003; Moisa et al., 2009).”
Background
Metadata
- Authors
- Bestmann, S., Baudewig, J., & Frahm, J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2003-02-19
- Volume
- 17
- Issue
- 3
- Pages
- 309-316
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2156288014
- Cited by
- 83
- References
- 2
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.