The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Comparison of right ventricular volume measurements between axial and short axis orientation using steady‐state free precession magnetic resonance imaging
Abstract
Purpose: To compare right ventricular (RV) volume measurements and their reproducibility between axial and short axis orientation acquisition techniques. Materials and Methods: Measurements of RV volumes from data sets acquired in axial and short axis orientations were compared in 20 normal subjects. The observer variabilities were assessed and the left ventricle (LV) and RV stroke volumes (SV) were compared. Results: There was a significant and systematic difference in the EDV and ESV volumes between the axial and short axis methods. The latter method resulted in larger volumes (mean bias EDV 7.5 ± 13.2, 4.7% difference; ESV 7.2 ± 8.6, 10.7% difference). The axial method had lower intra‐ and interobserver variability than the short axis method. The standard deviation of the difference (SDD) and the limits of agreement were consistently lower for the axial method. The mean differences between LV and RV stroke volumes expressed as mean ± 1 SD (r 2 =correlation coefficient) were: axial 7.6 ± 9.1 (r 2 = 0.93); and short axis 7.4 ± 10.8 (r 2 = 0.90). Conclusion: There is a significant systematic difference between volumes measured using the two different orientations. The axial orientation resulted in better inter‐ and intraobserver reproducibility. J. Magn. Reson. Imaging 2003;18:25–32. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Schulz-Menger, J., Bluemke, D. A., Bremerich, J., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Kim, R. J., von Knobelsdorff-Brenkenhoff, F., Kramer, C. M., Pennell, D. J., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-35 · Cited by 2,097
Self-citationHaddad, F., Hunt, S. A., Rosenthal, D. N., & Murphy, D. J. (2008) · Circulation · doi:10.1161/circulationaha.107.653576 · Cited by 1,523
Hudsmith†, L., Petersen†, S., Francis, J., Robson, M., & Neubauer, S. (2005) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640500295516 · Cited by 627
Geva, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-9 · Cited by 582
Maceira, A. M., Prasad, S. K., Khan, M., & Pennell, D. J. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl336 · Cited by 561
Fratz, S., Chung, T., Greil, G. F., Samyn, M. M., Taylor, A. M., Valsangiacomo Buechel, E. R., Yoo, S.-J., & Powell, A. J. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-51 · Cited by 507
Gulati, A., Ismail, T. F., Jabbour, A., Alpendurada, F., Guha, K., Ismail, N. A., Raza, S., Khwaja, J., Brown, T. D. H., Morarji, K., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.002518 · Cited by 342
Mooij, C. F., de Wit, C. J., Graham, D. A., Powell, A. J., & Geva, T. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21407 · Cited by 297
Gerche, A. L., Claessen, G., Van de Bruaene, A., Pattyn, N., Van Cleemput, J., Gewillig, M., Bogaert, J., Dymarkowski, S., Claus, P., & Heidbuchel, H. (2013) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.112.980037 · Cited by 265
Yamasaki, Y., Nagao, M., Yamamura, K., Yonezawa, M., Matsuo, Y., Kawanami, S., Kamitani, T., Higuchi, K., Sakamoto, I., Shiokawa, Y., et al. (2014) · European Radiology · doi:10.1007/s00330-014-3344-1 · Cited by 46
Koskenvuo, J. W., Karra, H., Lehtinen, J., Niemi, P., Pärkkä, J., Knuuti, J., & Hartiala, J. J. (2007) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2007.00764.x · Cited by 28
Gürdoğan, M., Ustabaşıoğlu, F. E., Kula, O., & Korkmaz, S. (2019) · Medicina · doi:10.3390/medicina55060260 · Cited by 6
Metadata
- Authors
- Alfakih, K., Plein, S., Bloomer, T., Jones, T., Ridgway, J., & Sivananthan, M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2003-06-13
- Volume
- 18
- Issue
- 1
- Pages
- 25-32
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2025744156
- Cited by
- 246
- References
- 1
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.