Precision of the CASL‐perfusion MRI technique for the measurement of cerebral blood flow in whole brain and vascular territories
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Purpose: To analyze the precision of cerebral blood flow (CBF) measurements made with continuous arterial spin labeling(CASL) perfusion magnetic resonance imaging (MRI) over experimentally relevant intervals. Materials and Methods: CASL perfusion MRI measurements of CBF on a 1.5‐T GE Signa magnet were repeated in young healthy male and female subjects at one hour and one week. Precision of the measurement was evaluated at both time intervals. Results: CASL perfusion MRI measurements of CBF yielded within‐subject coefficients of variation (wsCV) of 5.8% for global and 13% for individual vascular regions when measurements were repeated within one hour. Differences in these values represent the error in post‐processing. Global and regional CBF measurements over one week yielded wsCVs of 13% and 14%, respectively. At one week, error secondary to physiologic variability affected global and regional measurements to the same degree and masked the software post‐processing error seen at one hour. The magnitude of the difference in repeated measures correlated with the magnitude of the measurement. Conclusion: CASL perfusion MRI CBF measurements are accurate and precise. Variability over longer periods of time appears attributable to physiologic factors. Repeatability of the CASL measurement is sensitive to the magnitude of the measurement. This should be taken into account when studies requiring repeated measures involve subjects with significant variability in CBF. J. Magn. Reson. Imaging 2003;18:649–655. © 2003 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Experimental design and the relative sensitivity of BOLD and perfusion fMRI
Aguirre, G. K., Detre, J. A., Zarahn, E., & Alsop, D. C. (2002) · NeuroImage · doi:10.1006/nimg.2001.0990 · Cited by 403 · cited 1×
“However, due to the pair-wise subtraction of adjacently acquired images and the subsequent calibration process to produce an absolute measure of CBF, the slow drift effects are eliminated in arterial spin labeling (ASL) (19).”
BackgroundSelf-citation
Cited by
Non-invasive measurement of perfusion: a critical review of arterial spin labelling techniques
Petersen, E. T., Zimine, I., Ho, Y.-C. L., & Golay, X. (2006) · The British Journal of Radiology · doi:10.1259/bjr/67705974 · Cited by 352
Preoperative cerebral blood flow is diminished in neonates with severe congenital heart defects
Licht, D. J., Wang, J., Silvestre, D. W., Nicolson, S. C., Montenegro, L. M., Wernovsky, G., Tabbutt, S., Durning, S. M., Shera, D. M., Gaynor, J. W., et al. (2004) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.07.022 · Cited by 332
Self-citationAbnormal Metabolic Network Activity in Parkinson'S Disease: Test—Retest Reproducibility
Ma, Y., Tang, C., Spetsieris, P. G., Dhawan, V., & Eidelberg, D. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600358 · Cited by 312
Xu, G., Rowley, H. A., Wu, G., Alsop, D. C., Shankaranarayanan, A., Dowling, M., Christian, B. T., Oakes, T. R., & Johnson, S. C. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1462 · Cited by 280
Wang, J., Zhang, Y., Wolf, R. L., Roc, A. C., Alsop, D. C., & Detre, J. A. (2005) · Radiology · doi:10.1148/radiol.2351031663 · Cited by 271
Self-citationPerfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
Test–retest reliability of arterial spin labeling with common labeling strategies
Chen, Y., Wang, D. J. J., & Detre, J. A. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22345 · Cited by 238
Self-citationArterial spin-labeled perfusion MRI in basic and clinical neuroscience
Detre, J. A., Wang, J., Wang, Z., & Rao, H. (2009) · Current Opinion in Neurology · doi:10.1097/wco.0b013e32832d9505 · Cited by 236
Self-citationYu, G., Floyd, T. F., Durduran, T., Zhou, C., Wang, J., Detre, J. A., & Yodh, A. G. (2007) · Optics Express · doi:10.1364/oe.15.001064 · Cited by 223
Self-citationArterial Spin Labeling Blood Flow MRI: Its Role in the Early Characterization of Alzheimer's Disease
Alsop, D. C., Dai, W., Grossman, M., & Detre, J. A. (2010) · Journal of Alzheimer's Disease · doi:10.3233/jad-2010-091699 · Cited by 215
“Existing data suggest test-retest reliability comparable to other modalities [13] [14] [15].”
Self-citationIshiuji, Y., Coghill, R. C., Patel, T. S., Oshiro, Y., Kraft, R. A., & Yosipovitch, G. (2009) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2009.09308.x · Cited by 173
Asllani, I., Habeck, C., Scarmeas, N., Borogovac, A., Brown, T. R., & Stern, Y. (2008) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600570 · Cited by 172
“…analysis of continuous arterial spin labeling perfusion MRI in Alzheimer’s disease Iris Asllani1, Christian Habeck2, Nikolaos Scarmeas2,3, Ajna Borogovac4, Truman R Brown1,4 and Yaakov Stern2,3,5 1Department of Radiology, Columbia University, New York, New York, USA; 2The Cognitive Neuroscience”
Resting‐state functional connectivity and nicotine addiction: prospects for biomarker development
Fedota, J. R., & Stein, E. A. (2015) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12882 · Cited by 164
Fan, A. P., Jahanian, H., Holdsworth, S. J., & Zaharchuk, G. (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x16636393 · Cited by 158
“ASL reproducibility scans revealed similar 14% variation for an interval of a week, and 6% variation even for measurements repeated within an hour.(49) To account for normal diurnal variations in CBF,(50,51) perfusion scans should be performed at the same time of day for optimal reproducibility.”
BackgroundHao, X., Xu, D., Bansal, R., Dong, Z., Liu, J., Wang, Z., Kangarlu, A., Liu, F., Duan, Y., Shova, S., et al. (2013) · Human Brain Mapping · doi:10.1002/hbm.21440 · Cited by 63
“Implementing more recent procedures that measure cerebral perfusion using MRI [Detre and Wang, 2002; Floyd et al., 2003] would provide a measure of resting functional activity throughout the entire brain that could be more versatile and more revealing of biological relationships with other imaging measures in correlat…”
MethodWolf, R. C., Thomann, P. A., Sambataro, F., Vasic, N., Schmid, M., & Wolf, N. D. (2012) · European Archives of Psychiatry and Clinical Neuroscience · doi:10.1007/s00406-012-0303-1 · Cited by 54
Extraversion and its positive emotional core—further evidence from neuroscience
Hermes, M., Hagemann, D., Naumann, E., & Walter, C. (2011) · Emotion · doi:10.1037/a0021550 · Cited by 39
Metadata
- Authors
- Floyd, T. F., Ratcliffe, S. J., Wang, J., Resch, B., & Detre, J. A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2003-11-18
- Volume
- 18
- Issue
- 6
- Pages
- 649-655
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2161846593
- Cited by
- 126
- References
- 1
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.