Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 288

The DOI matches its Crossref record.

Spatial variation in cartilage T2 of the knee

Open access
Smith, Harvey E., Mosher, Timothy J., Dardzinski, Bernard J., Collins, Belinda G., Collins, Christopher M., Yang, Qing X., Schmithorst, Vincent J., Smith, Michael B.·2001·Journal of Magnetic Resonance Imaging

Abstract

Technical limitations imposed by resolution and B1 homogeneity have thus far limited quantitative in vivo T2 mapping of cartilage to the patella. The purpose of this study is to develop T2 mapping of the femoral/tibial joint and assess regional variability of cartilage T2 in the knee. Quantitative in vivo T2 mapping of the knee was performed on 15 asymptomatic adults (age, 22–44) using a 3T MR scanner. There is a consistent pattern of spatial variation in cartilage T2 with longer values near the articular surface. The greatest variation occurs in the patella, where T2 increases from 45.3 ± 2.5 msec at a normalized distance of 0.33–67 ± 5.5 msec at a distance of 1.0. These results demonstrate feasibility of performing in vivo T2 mapping of femoral tibial cartilage. Except for the superficial 15% where T2 values are lower, the spatial variation in T2 of femoral and tibial cartilage is similar to patellar cartilage. J. Magn. Reson. Imaging 2001;14:50–55. © 2001 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.1150

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 288

Metadata

Authors
Smith, H. E., Mosher, T. J., Dardzinski, B. J., Collins, B. G., Collins, C. M., Yang, Q. X., Schmithorst, V. J., & Smith, M. B.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2001-06-26
Volume
14
Issue
1
Pages
50-55
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1964208449
Cited by
288
References
0
FWCI
7.29
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Spatial variation in cartilage T2 of the knee. https://app.cochat.ai/papers/10.1002/jmri.1150
The paper
Smith, H. E., Mosher, T. J., Dardzinski, B. J., Collins, B. G., Collins, C. M., Yang, Q. X., Schmithorst, V. J., & Smith, M. B. (2001). Spatial variation in cartilage T2 of the knee. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1150

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.