CoChat

Improved mapping of pharmacologically induced neuronal activation using the IRON technique with superparamagnetic blood pool agents

Chen, Yin‐Ching I., Mandeville, Joseph B., Nguyen, Tuong V., Talele, Anjali, Cavagna, Friedrich, Jenkins, Bruce G. · 2001 · Journal of Magnetic Resonance Imaging
Cited by 78

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The use of functional magnetic resonance imaging (fMRI) techniques for evaluation of pharmacologic stimuli has great potential for understanding neurotransmitter dynamics for a number of brain disorders, such as drug abuse, schizophrenia, epilepsy, or neurodegeneration. Unfortunately, blood oxygenation level‐dependent (BOLD) imaging at common fields strengths, such as 1.5 or 3 T, has very low sensitivity and contrast‐to‐noise ratios (CNRs). We demonstrate here the utility of using an intravascular superparamagnetic iron oxide contrast agent with a long plasma half‐life for evaluation of hemodynamic changes related to dopaminergic stimuli using amphetamine or the cocaine analog 2β‐carbomethoxy‐3β‐(4‐fluorophenyl)tropane (CFT). We refer to this technique as increased relaxation with iron oxide nanoparticles (IRON). Results obtained here show that even at field strengths as high as 4.7 T, one can obtain increases in CNR by factors of 2–3 over BOLD imaging that lead to greater than an order of magnitude increase in statistical power with greatly increased sensitivity to hemodynamic changes in brain regions difficult to observe using BOLD imaging. Furthermore, use of the intravascular contrast agent allows for a meaningful physiologic parameter to be measured (relative cerebral blood volume (rCBV)), compared to conventional BOLD imaging. J. Magn. Reson. Imaging 2001;14:517–524. © 2001 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.1215

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 78

Metadata

Authors
Chen, Y. I., Mandeville, J. B., Nguyen, T. V., Talele, A., Cavagna, F., & Jenkins, B. G.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2001-10-31
Volume
14
Issue
5
Pages
517-524
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2131375848
Cited by
78
References
4
FWCI
3.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved mapping of pharmacologically induced neuronal activation using the IRON technique with superparamagnetic blood pool agents. https://app.cochat.ai/papers/10.1002/jmri.1215
The paper
Chen, Y. I., Mandeville, J. B., Nguyen, T. V., Talele, A., Cavagna, F., & Jenkins, B. G. (2001). Improved mapping of pharmacologically induced neuronal activation using the IRON technique with superparamagnetic blood pool agents. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1215

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.