The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T
Abstract
The use of magnetic resonance (MR) imaging is investigated for noninvasively estimating the oxygen saturation of human blood (%HbO 2) in vivo by means of relaxation characteristics identified in earlier MR spectrometry studies. To this end, a sequence is presented for determining the T 2 of vascular blood in regions in which motions of the body and of the blood itself present a major challenge. With use of this sequence on a commercial 1.5‐T whole‐body imager, the relationship between the T 2 and %HbO 2 of blood is calibrated in vitro for the conditions expected in vivo. T 2 varies predictably from about 30 to 250 msec as %HbO 2 varies from 30% to 96%. T 2 values measured in situ for vascular blood in the mediastinum of several healthy subjects qualitatively reflected the behavior observed in vitro. Estimates of %HbO 2 for these vessels obtained with the in vitro calibration appear reasonable, particularly for venous blood, although difficulties arise in selecting the appropriate calibration factors. These encouraging initial results support a more systematic study of potential sources of error and an examination of the accuracy of in vivo measurements by comparison with direct measurements of %HbO 2 in vessels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Data Reduction and Error Analysis for the Physical Sciences.
C., E. L., & Bevington, P. R. (1972) · Journal of the American Statistical Association · doi:10.2307/2284752 · Cited by 3,534
(1971) · Annals of Internal Medicine · doi:10.7326/0003-4819-75-6-991_4 · Cited by 2,379
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging
Haase, A. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130109 · Cited by 693
Luz, Z., & Meiboom, S. (1963) · The Journal of Chemical Physics · doi:10.1063/1.1734254 · Cited by 546
Book of Abstracts, Society of Magnetic Resonance in Medicine
Tanttu, J. I., & SEPPONEN, R. E. (1993) · Cited by 395
Gillis, P., & Koenig, S. H. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050404 · Cited by 353
NMR relaxation times of blood: dependence on field strength, oxidation state, and cell integrity.
Gomori, J. M., Grossman, R. I., Yu-Ip, C., & Asakura, T. (1987) · PubMed · Cited by 213
NMR Relaxation Times of Blood: Dependence on Field Strength, Oxidation State, and Cell Integrity
Gomori, J. M., Grossman, R. I., Yu-Ip, C., & Asakura, T. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198707000-00025 · Cited by 195
Broadband Decoupling in High-Resolution Nuclear Magnetic Resonance Spectroscopy
Levitt, M. H., Freeman, R., & Frenkiel, T. A. (1983) · Advances in magnetic and optical resonance · doi:10.1016/b978-0-12-025511-5.50008-6 · Cited by 159
Magnetic relaxation in blood and blood clots
Bryant, R. G., Marill, K. A., Blackmore, C. C., & Francis, C. W. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130112 · Cited by 136
Methodology for the measurement and analysis of relaxation times in proton imaging
MacFall, J. R., Wehrli, F. W., Breger, R. K., & Johnson, G. A. (1987) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(87)90022-1 · Cited by 97
Flow‐independent magnetic resonance projection angiography
Wright, G. A., Nishimura, D. G., & Macovski, A. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170117 · Cited by 77
Self-citationT2 effect of hemoglobin concentration: assessment with in vitro MR spectroscopy.
Hayman, L. A., Ford, J. J., Taber, K. H., Saleem, A., Round, M. E., & Bryan, R. N. (1988) · Radiology · doi:10.1148/radiology.168.2.3393669 · Cited by 47
On the origin of paramagnetic inhomogeneity effects in blood
Brooks, R. A., Brunetti, A., Alger, J. R., & Chiro, G. D. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910120210 · Cited by 39
Matwiyoff, N. A., Gasparovic, C., Mazurchuk, R., & Matwiyoff, G. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90102-8 · Cited by 35
Cited by
Time course EPI of human brain function during task activation
Bandettini, P. A., Wong, E. C., Hinks, R. S., Tikofsky, R. S., & Hyde, J. S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250220 · Cited by 1,935
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Boxerman, J. L., Bandettini, P. A., Kwong, K. K., Baker, J. R., Davis, T. L., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340103 · Cited by 594
Biophysical and Physiological Origins of Blood Oxygenation Level-Dependent fMRI Signals
Kim, S.-G., & Ogawa, S. (2012) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2012.23 · Cited by 547
Sun, L., Macgowan, C. K., Sled, J. G., Yoo, S.-J., Manlhiot, C., Porayette, P., Grosse-Wortmann, L., Jaeggi, E., McCrindle, B. W., Kingdom, J., et al. (2015) · Circulation · doi:10.1161/circulationaha.114.013051 · Cited by 533
Metadata
- Authors
- Wright, G. A., Hu, B. S., & Macovski, A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1991-05
- Volume
- 1
- Issue
- 3
- Pages
- 275-283
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2009283203
- Cited by
- 327
- References
- 19
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.