Visualizing tissue compliance with MR imaging
The DOI matches its Crossref record.
Abstract
We propose a method for visualizing the mechanical properties of tissue based on the use of periodic mechanical compression in conjunction with phase‐contrast MR imaging. A specialized mechanical transducer was used to provide programmable compression pulses to the surface of compliant phantoms. These compression pulses were synchronized to a spin‐echo sequence with motion‐sensitizing gradients to generate phase information reflecting spin displacement throughout the phantom. This sequence was tested with two agarose gel phantoms. The first was a cylinder containing three parallel layers of varying compliance and the second was composed of a semirigid sphere suspended in a uniform layer of decreased elastic modulus. Images showed complex patterns of motion throughout the phantom, which correlated with expected motion behavior of the phantom structures. This indicates that the biomechanical properties of tissues may be elucidated through the use of motion‐sensitized MR imaging and suggests that a form of image contrast relating to tissue elasticity may be feasible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics
Sarvazyan, A. P., Rudenko, O. V., Swanson, S. D., Fowlkes, J. B., & Emelianov, S. Y. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00110-0 · Cited by 1,727
Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
Manduca, A., Oliphant, T. E., Dresner, M. A., Mahowald, J. L., Kruse, S. A., Amromin, E., Felmlee, J. P., Greenleaf, J. F., & Ehman, R. L. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00039-6 · Cited by 1,103
Elastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
Magnetic resonance elastography: A review
Mariappan, Y. K., Glaser, K. J., & Ehman, R. L. (2010) · Clinical Anatomy · doi:10.1002/ca.21006 · Cited by 680
Imaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
Magnetic resonance elastography of the brain
Kruse, S. A., Rose, G. H., Glaser, K. J., Manduca, A., Felmlee, J. P., Jack, C. R., & Ehman, R. L. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.08.030 · Cited by 424
Catheline, S., Gennisson, J.-L., Delon, G., Fink, M., Sinkus, R., Abouelkaram, S., & Culioli, J. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1815075 · Cited by 409
Tissue characterization using magnetic resonance elastography: preliminary results*
Kruse, S. A., Smith, J. A., Lawrence, A. J., Dresner, M. A., Manduca, A., Greenleaf, J. F., Ehman, R. L., Kruse, S. A., Smith, J. A., Lawrence, A. J., et al. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/313 · Cited by 340
Sinkus, R., Siegmann, K., Xydeas, T., Tanter, M., Claussen, C., & Fink, M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21404 · Cited by 332
Plewes, D. B., Bishop, J., Samani, A., & Sciarretta, J. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/6/314 · Cited by 318
Self-citationNon‐invasive measurement of brain viscoelasticity using magnetic resonance elastography
Sack, I., Beierbach, B., Hamhaber, U., Klatt, D., & Braun, J. (2008) · NMR in Biomedicine · doi:10.1002/nbm.1189 · Cited by 316
Magnetic resonance elastography
Muthupillai, R., & Ehman, R. L. (1996) · Nature Medicine · doi:10.1038/nm0596-601 · Cited by 284
Cardiovascular magnetic resonance phase contrast imaging
Nayak, K. S., Nielsen, J.-F., Bernstein, M. A., Markl, M., D. Gatehouse, P., M. Botnar, R., Saloner, D., Lorenz, C., Wen, H., S. Hu, B., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0172-7 · Cited by 264
Assessment of liver viscoelasticity using multifrequency MR elastography
Asbach, P., Klatt, D., Hamhaber, U., Braun, J., Somasundaram, R., Hamm, B., & Sack, I. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21636 · Cited by 264
General review of magnetic resonance elastography
Low, G. (2016) · World Journal of Radiology · doi:10.4329/wjr.v8.i1.59 · Cited by 123
Elastography imaging: the 30 year perspective
Ormachea, J., & Parker, K. J. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abca00 · Cited by 104
Brain palpation from physiological vibrations using MRI
Zorgani, A., Souchon, R., Dinh, A.-H., Chapelon, J.-Y., Ménager, J.-M., Lounis, S., Rouvière, O., & Catheline, S. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1509895112 · Cited by 69
“Synchronization with the shear-wave source is, thus, necessary (9, 10), which penalizes its potential implementation based on natural shear waves.”
Metadata
- Authors
- Plewes, D. B., Betty, I., Urchuk, S. N., & Soutar, I.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1995-11
- Volume
- 5
- Issue
- 6
- Pages
- 733-738
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2167594743
- Cited by
- 166
- References
- 0
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.