Functional MR imaging using gradient‐echo echo‐planar imaging in the presence of large static field inhomogeneities
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
At 1.5 T, the field strength of most clinical MR imagers, gradient‐echo Imaging Is the primary imaging method for measuring brain activation, as such sequences are highly sensitive to changes in blood oxygenation or T2* effects. Unfortunately, gradient‐echo sequences are also extremely sensitive to magnetic field inhomogeneities, and this sensitivity has precluded examination of regions of cortex near field inhomogeneities with functional MR imaging. This article presents a gradient‐echo echo‐planar imaging method that uses variable amplitude scaling on the slice‐select refocusing lobe to generate images compensated for static field inhomogeneities. A technique for constructing composite Images to be used in statistical tests for activation is also presented. The method is shown to produce clean activation maps in the presence of large static field inhomogeneities. The technique retains the sensitivity of gradient‐ echo imaging to changes in blood oxygenation while removing the sensitivity to large static field inhomogeneities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Fox, P. T., & Raichle, M. E. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.4.1140 · Cited by 2,056
Functional mapping of the human visual cortex by magnetic resonance imaging
Belliveau, J. W., Kennedy, D. N., McKinstry, R. C., Buchbinder, B. R., Weisskoff, R. M., Cohen, M. S., Vevea, J. M., Brady, T. J., & Rosen, B. R. (1991) · Science · doi:10.1126/science.1948051 · Cited by 1,883
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Cited by
Theory and application of static field inhomogeneity effects in gradient‐echo imaging
Reichenbach, J. R., Venkatesan, R., Yablonskiy, D. A., Thompson, M. R., Lai, S., & Haacke, E. M. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070203 · Cited by 285
Image distortion correction in EPI: Comparison of field mapping with point spread function mapping
Zeng, H., & Constable, R. T. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10200 · Cited by 274
Self-citationCompensation of susceptibility-induced bold sensitivity losses in echo-planar fMRI imaging
Deichmann, R., Josephs, O., Hutton, C., Corfield, D. R., & Turner, R. (2002) · NeuroImage · doi:10.1006/nimg.2001.0985 · Cited by 253
Stenger, V. A., Boada, F. E., & Noll, D. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200010)44:4<525::aid-mrm5>3.0.co;2-l · Cited by 166
Metadata
- Authors
- Constable, R. T.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1995-11
- Volume
- 5
- Issue
- 6
- Pages
- 746-752
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2131433974
- Cited by
- 83
- References
- 4
- FWCI
- 1.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.