The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
1H metabolite relaxation times at 3.0 tesla: Measurements of T1 and T2 values in normal brain and determination of regional differences in transverse relaxation
Open accessAbstract
Purpose: To measure 1 H relaxation times of cerebral metabolites at 3 T and to investigate regional variations within the brain. Materials and Methods: Investigations were performed on a 3.0‐T clinical whole‐body magnetic resonance (MR) system. T2 relaxation times of N‐acetyl aspartate (NAA), total creatine (tCr), and choline compounds (Cho) were measured in six brain regions of 42 healthy subjects. T1 relaxation times of these metabolites and of myo‐inositol (Ins) were determined in occipital white matter (WM), the frontal lobe, and the motor cortex of 10 subjects. Results: T2 values of all metabolites were markedly reduced with respect to 1.5 T in all investigated regions. T2 of NAA was significantly (P < 0.001) shorter in the motor cortex (247 ± 13 msec) than in occipital WM (301 ± 18 msec). T2 of the tCr methyl resonance showed a corresponding yet less pronounced decrease (162 ± 16 msec vs. 178 ± 9 msec, P = 0.021). Even lower T2 values for all metabolites were measured in the basal ganglia. Metabolite T1 relaxation times at 3.0 T were not significantly different from the values at 1.5 T. Conclusion: Transverse relaxation times of the investigated cerebral metabolites exhibit an inverse proportionality to magnetic field strength, and especially T2 of NAA shows distinct regional variations at 3 T. These can be attributed to differences in relative WM/gray matter (GM) contents and to local paramagnetism. J. Magn. Reson. Imaging 2004;19:537–545. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo 1 H NMR spectroscopy of the human brain at 7 T
Tkáč, I., Andersen, P., Adriany, G., Merkle, H., Uǧurbil, K., & Gruetter, R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1213 · Cited by 394
Cited by
2-hydroxyglutarate detection by magnetic resonance spectroscopy in IDH-mutated patients with gliomas
Choi, C., Ganji, S. K., DeBerardinis, R. J., Hatanpaa, K. J., Rakheja, D., Kovacs, Z., Yang, X.-L., Mashimo, T., Raisanen, J. M., Marin-Valencia, I., et al. (2012) · Nature Medicine · doi:10.1038/nm.2682 · Cited by 839
Current practice in the use of MEGA-PRESS spectroscopy for the detection of GABA
Mullins, P. G., McGonigle, D. J., O'Gorman, R. L., Puts, N. A. J., Vidyasagar, R., Evans, C. J., & Edden, R. A. E. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.004 · Cited by 553
Use of tissue water as a concentration reference for proton spectroscopic imaging
Gasparovic, C., Song, T., Devier, D., Bockholt, H. J., Caprihan, A., Mullins, P. G., Posse, S., Jung, R. E., & Morrison, L. A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20901 · Cited by 509
1H MR Spectroscopy of the Brain: Absolute Quantification of Metabolites
Jansen, J. F. A., Backes, W. H., Nicolay, K., & Kooi, M. E. (2006) · Radiology · doi:10.1148/radiol.2402050314 · Cited by 405
Stone, J. M., Dietrich, C., Edden, R., Mehta, M. A., De Simoni, S., Reed, L. J., Krystal, J. H., Nutt, D., & Barker, G. J. (2012) · Molecular Psychiatry · doi:10.1038/mp.2011.171 · Cited by 295
Metadata
- Authors
- Träber, F., Block, W., Lamerichs, R., Gieseke, J., & Schild, H. H.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2004-04-21
- Volume
- 19
- Issue
- 5
- Pages
- 537-545
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2158514967
- Cited by
- 249
- References
- 1
- FWCI
- 10.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 1H metabolite relaxation times at 3.0 tesla: Measurements of T1 and T2 values in normal brain and determination of regional differences in transverse relaxation. https://app.cochat.ai/papers/10.1002/jmri.20053
- The paper
- Träber, F., Block, W., Lamerichs, R., Gieseke, J., & Schild, H. H. (2004). 1H metabolite relaxation times at 3.0 tesla: Measurements of T1 and T2 values in normal brain and determination of regional differences in transverse relaxation. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.20053
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.