In vivo diffusion tensor imaging of the human calf muscle
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Purpose: To demonstrate the feasibility of in vivo calf muscle fiber tracking in human subjects. Materials and Methods: An EPI‐based diffusion tensor imaging (DTI) sequence with six‐direction diffusion gradient sensitization was implemented, and DT images were acquired at 3 Tesla on five subjects using an extremity coil. The mean diffusivity, fractional anisotropy (FA), and fiber angle (with respect to the magnet z‐axis) were measured in different muscles, and fibers were tracked from several regions of interest (ROIs). Results: The fiber orientations in the current DTI studies agree well with those determined in previous spectroscopic studies. The orientation angles ranged from 13.4° in the lateral gastrocnemius to 48.5° in the medial soleus. The diffusion ellipsoid in muscle tissue is anisotropic and approximates a prolate model, as shown by color maps of the anisotropy. Fibers were tracked from the different muscle regions, and the unipennate and bipennate structure of muscle fibers was visualized. Conclusion: The study clearly shows that in vivo fiber tracking of muscle fibers is feasible and could potentially be applied to study muscle structure function relationships. J. Magn. Reson. Imaging 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547 · cited 3×
“The FA was calculated from the eigenvalues as (1):”
BackgroundMethodReduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echo
Reese, T. G., Heid, O., Weisskoff, R. M., & Wedeen, V. J. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10308 · Cited by 1,227 · cited 1×
“Furthermore, eddy-current distortions in the DW images were reduced by a dual 180° pulse design that compensates for eddy-current effects (13).”
BackgroundMusculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Gold, G. E., Han, E., Stainsby, J., Wright, G., Brittain, J., & Beaulieu, C. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.2.1830343 · Cited by 517 · cited 1×
“The signal-tonoise ratio (SNR) is a limiting factor in muscle imaging because muscle has low T2 compared to brain tissue (16).”
BackgroundStatistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise
Basser, P. J., & Pajevic, S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<41::aid-mrm8>3.0.co;2-o · Cited by 318 · cited 1×
“Isotropic pixels should only appear white; however, noise in the acquired images propagates into the tensor calculation and in fact affects isotropic/low anisotropy structures more than high anisotropy regions, introducing spurious anisotropy (14).”
BackgroundMuscle fibre type adaptation in the elderly human muscle
Andersen, J. L. (2003) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2003.00299.x · Cited by 316
Park, H.-J., Westin, C.-F., Kubicki, M., Maier, S. E., Niznikiewicz, M., Baer, A., Frumin, M., Kikinis, R., Jolesz, F. A., McCarley, R. W., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.04.036 · Cited by 295
Force–length characteristics of in vivo human skeletal muscle
Maganaris, C. N. (2001) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2001.00799.x · Cited by 278 · cited 2×
“It is fast and allows real-time measurements of fiber lengths and pennation angles to be made even during isometric contraction (29,30).”
BackgroundMethodJärvinen, T. A. H., Józsa, L., Kannus, P., Järvinen, T. L. N., & Järvinen, M. (2002) · Journal of Muscle Research & Cell Motility · doi:10.1023/a:1020904518336 · Cited by 249
Validation of diffusion tensor MRI‐based muscle fiber tracking
Damon, B. M., Ding, Z., Anderson, A. W., Freyer, A. S., & Gore, J. C. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10198 · Cited by 241 · cited 4×
“It should be noted that the focus of the current study does not include measurements of pennation angles, which would require more sophisticated tracking of the aponeurosis as well as bundling of fibers with similar characteristics (9).”
BackgroundMethodInfluentialDiffusion tensor MRI of the human kidney
Ries, M., Jones, R. A., Basseau, F., Moonen, C. T. W., & Grenier, N. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1149 · Cited by 236 · cited 2×
“This prolate model of diffusion is similar to the type of diffusion anisotropy found in the kidney medulla (6).”
MethodForce‐length characteristics of the in vivo human gastrocnemius muscle
Maganaris, C. N. (2003) · Clinical Anatomy · doi:10.1002/ca.10064 · Cited by 235 · cited 4×
“It is fast and allows real-time measurements of fiber lengths and pennation angles to be made even during isometric contraction (29,30).”
BackgroundMethodResultInfluentialIn vivo MR tractography using diffusion imaging
Bammer, R., Acar, B., & Moseley, M. E. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00311-x · Cited by 232 · cited 1×
“, fractional anisotropy (FA) and lattice index) and reflects microstructural organization (1,2).”
BackgroundSonographic studies of human soleus and gastrocnemius muscle architecture: gender variability
Chow, R. S., Medri, M. K., Martin, D. C., Leekam, R. N., Agur, A. M., & McKee, N. H. (2000) · European Journal of Applied Physiology · doi:10.1007/s004210050677 · Cited by 223 · cited 2×
“US and morphologic measurements of the soleus indicate that it is compartmentalized into a unipennate posterior group and a bipennate anterior group (22,26).”
BackgroundMethodAbdomen: Diffusion-weighted MR Imaging with Pulse-triggered Single-Shot Sequences
Mürtz, P., Flacke, S., Träber, F., van den Brink, J. S., Gieseke, J., & Schild, H. H. (2002) · Radiology · doi:10.1148/radiol.2241011117 · Cited by 222
Ultrasound of nerve and muscle
Walker, F. O., Cartwright, M. S., Wiesler, E. R., & Caress, J. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.10.022 · Cited by 216
Galbán, C. J., Maderwald, S., Uffmann, K., de Greiff, A., & Ladd, M. E. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1186-2 · Cited by 169 · cited 8×
“Variations of 1 in different muscles were attributed to the presence of structural barriers whose dimensions approximately matched the average distance diffused during the typical diffusion times used in spin-echo echo-planar diffusion sequences (11).”
BackgroundMethodResultInfluentialCardiac diffusion MRI without motion effects
Dou, J., Reese, T. G., Tseng, W. I., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10188 · Cited by 168 · cited 1×
“DTI has been used extensively to study the microstructural architecture of the normal and diseased brain (2–4) and has been applied relatively less frequently to other organs, such as the abdomen (5), kidney (6), heart (7), skeletal muscle (8–11), and lingual muscles (12).”
MethodDetermination of mouse skeletal muscle architecture using three‐dimensional diffusion tensor imaging
Heemskerk, A. M., Strijkers, G. J., Vilanova, A., Drost, M. R., & Nicolay, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20476 · Cited by 160
Fiber type composition of four hindlimb muscles of adult Fisher 344 rats
Staron, R. S., Kraemer, W. J., Hikida, R. S., Fry, A. C., Murray, J. D., & Campos, G. E. R. (1999) · Histochemistry and Cell Biology · doi:10.1007/s004180050341 · Cited by 159
Kinoshita, T., Yashiro, N., Ihara, N., Funatu, H., Fukuma, E., & Narita, M. (2002) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200211000-00033 · Cited by 143 · cited 1×
“Partial Fourier allows shorter readout times, which translates to a reduction in blurring and susceptibility-based artifacts compared to a full k-space acquisition (17,18).”
BackgroundDiffusion tensor imaging in biomechanical studies of skeletal muscle function
VAN DONKELAAR, C. C., KRETZERS, L. J. G., BOVENDEERD, P. H. M., LATASTER, L. M. A., NICOLAY, K., JANSSEN, J. D., & DROST, M. R. (1999) · Journal of Anatomy · doi:10.1046/j.1469-7580.1999.19410079.x · Cited by 141 · cited 2×
“DTI studies of muscle have been performed in vitro on striated muscle, and fiber directions obtained from DTI have been shown to conform to fascicle striation patterns that are visible on high-resolution MRI, and with fiber directions in an actual longitudinal section (ALS) through the same muscle (8).”
BackgroundMethodDocumentation and three‐dimensional modelling of human soleus muscle architecture
Agur, A. M. R., Ng‐Thow‐Hing, V., Ball, K. A., Fiume, E. L., & McKee, N. H. (2003) · Clinical Anatomy · doi:10.1002/ca.10112 · Cited by 130
Diffusion-weighted imaging of the musculoskeletal system in humans
Baur, A., & Reiser, M. F. (2000) · Skeletal Radiology · doi:10.1007/s002560000243 · Cited by 124 · cited 1×
“Bauer and Reiser (10) performed musculoskeletal diffusionweighted imaging (DWI) with steady-state free precession (SSFP) sequences.”
BackgroundIn vivo measurement of diffusion and pseudo-diffusion in skeletal muscle at rest and after exercise
Morvan, D. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00096-l · Cited by 95 · cited 1×
“signal intensity and/or attenuation (19).”
Napadow, V., Chen, Q., Mai, V., So, P. T. C., & Gilbert, R. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76262-5 · Cited by 79 · cited 3×
“In vitro lingual muscle fiber orientation has been mapped by DTI and compared well with determinations made by optical imaging (two-photon excitation microscopy) methods (12).”
BackgroundMethodWater diffusion compartmentation at high b values in ischemic human brain.
Brugières, P., Thomas, P., Maraval, A., Hosseini, H., Combes, C., Chafiq, A., Ruel, L., Breil, S., Peschanski, M., & Gaston, A. (2004) · PubMed · Cited by 73
Finni, T. J., Hodgson, J. A., Lai, A. M., Edgerton, V. R., & Sinha, S. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00596.2003 · Cited by 72 · cited 2×
“The fiber arrangement is also radial in the superior part of the posterior soleus (27).”
BackgroundSelf-citationIn vivo diffusion tensor imaging of human calf muscle
Sinha, U. S., & Yao, L. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10035 · Cited by 70 · cited 1×
“ponential decay in muscle in the b-value range of 100– 1000 s/mm(2) (21).”
BackgroundSelf-citationMapping fiber orientation in human muscle by proton MR spectroscopic imaging
Vermathen, P., Boesch, C., & Kreis, R. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10396 · Cited by 63 · cited 2×
“The ROI locations and the imaging slice were chosen so that comparisons between the current DTI data and those from earlier studies using DTI and spectroscopy would be meaningful (11,15).”
BackgroundMethod
Cited by
Wang, L., Wang, C., Wu, S., Fan, Y., & Li, X. (2020) · Biomaterials Science · doi:10.1039/d0bm00269k · Cited by 233
Relationships between tissue microstructure and the diffusion tensor in simulated skeletal muscle
Berry, D. B., Regner, B., Galinsky, V., Ward, S. R., & Frank, L. R. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26993 · Cited by 86
Metadata
- Authors
- Sinha, S., Sinha, U., & Edgerton, V. R.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2006-05-25
- Volume
- 24
- Issue
- 1
- Pages
- 182-190
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2081412134
- Cited by
- 167
- References
- 29
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.