Optimal acquisition orders of diffusion‐weighted MRI measurements
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Purpose: To propose a new method to optimize the ordering of gradient directions in diffusion‐weighted MRI so that partial scans have the best spherical coverage. Materials and Methods: Diffusion‐weighted MRI often uses a spherical sampling scheme, which acquires images sequentially with diffusion‐weighting gradients in unique directions distributed isotropically on the hemisphere. If not all of the measurements can be completed, the quality of diffusion tensors fitted to the partial scan is sensitive to the order of the gradient directions in the scanner protocol. If the directions are in a random order, then a partial scan may cover some parts of the hemisphere densely but other parts sparsely and thus provide poor spherical coverage. We compare the results of ordering with previously published methods for optimizing the acquisition in simulation. Results: Results show that all methods produce similar results and all improve the accuracy of the estimated diffusion tensors significantly over unordered acquisitions. Conclusion: The new ordering method improves the spherical coverage of partial scans and has the advantage of maintaining the optimal coverage of the complete scan. J. Magn. Reson. Imaging 2007;25:1051–1058. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity
Tuch, D. S., Reese, T. G., Wiegell, M. R., Makris, N., Belliveau, J. W., & Wedeen, V. J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10268 · Cited by 1,548
An Introduction to Computational Diffusion MRI: the Diffusion Tensor and Beyond
Alexander, D. C. (2006) · Mathematics and Visualization · doi:10.1007/3-540-31272-2_5 · Cited by 70
Self-citation
Cited by
NODDI: Practical in vivo neurite orientation dispersion and density imaging of the human brain
Zhang, H., Schneider, T., Wheeler-Kingshott, C. A., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.072 · Cited by 3,288
Self-citationWhite matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
The B‐matrix must be rotated when correcting for subject motion in DTI data
Leemans, A., & Jones, D. K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21890 · Cited by 1,281
About “axial” and “radial” diffusivities
Wheeler‐Kingshott, C. A. M., & Cercignani, M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21965 · Cited by 885
Diffusion Tensor MR Imaging and Fiber Tractography: Technical Considerations
Mukherjee, P., Chung, S. W., Berman, J. I., Hess, C. P., & Henry, R. G. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1052 · Cited by 390
Jones, D. K., & Leemans, A. (2011) · Methods in Molecular Biology · doi:10.1007/978-1-61737-992-5_6 · Cited by 379
Alexander, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21646 · Cited by 331
Self-citationDell'Acqua, F., Scifo, P., Rizzo, G., Catani, M., Simmons, A., Scotti, G., & Fazio, F. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.09.033 · Cited by 304
Design of multishell sampling schemes with uniform coverage in diffusion MRI
Caruyer, E., Lenglet, C., Sapiro, G., & Deriche, R. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24736 · Cited by 302
Dell'Acqua, F., Simmons, A., Williams, S. C. R., & Catani, M. (2013) · Human Brain Mapping · doi:10.1002/hbm.22080 · Cited by 295
Focke, N. K., Yogarajah, M., Bonelli, S. B., Bartlett, P. A., Symms, M. R., & Duncan, J. S. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.031 · Cited by 282
Self-citationPalesi, F., Tournier, J.-D., Calamante, F., Muhlert, N., Castellazzi, G., Chard, D., D’Angelo, E., & Wheeler-Kingshott, C. A. M. (2015) · Brain Structure and Function · doi:10.1007/s00429-014-0861-2 · Cited by 203
“The diffusion weighting was distributed along 61 optimized non-collinear directions with a b value of 1,200 s/mm2 (Cook et al. 2007).”
MethodHistological validation of diffusion MRI fiber orientation distributions and dispersion
Schilling, K. G., Janve, V., Gao, Y., Stepniewska, I., Landman, B. A., & Anderson, A. W. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.10.046 · Cited by 195
“To do this, the full 100 gradient directions were re-ordered to minimize the electrostatic potential energy of any partial set of “N” directions, ensuring that these “N” directions are maximally uniformly distributed (Cook et al., 2007).”
Multi-echo fMRI of the cortical laminae in humans at 7T
Koopmans, P. J., Barth, M., Orzada, S., & Norris, D. G. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.02.042 · Cited by 160
“Then we rotated the z-axis of the cube towards one of 256 maximally different axes in one hemifield (provided by the Camino package (Cook et al., 2007), normally used to maximise sensitivity in diffusion imaging, calculated by electrostatic simulations).”
Sepehrband, F., Clark, K. A., Ullmann, J. F. P., Kurniawan, N. D., Leanage, G., Reutens, D. C., & Yang, Z. (2015) · Human Brain Mapping · doi:10.1002/hbm.22872 · Cited by 143
Winston, G. P., Micallef, C., Symms, M. R., Alexander, D. C., Duncan, J. S., & Zhang, H. (2014) · Epilepsy Research · doi:10.1016/j.eplepsyres.2013.11.004 · Cited by 137
Self-citationNeurite density index is sensitive to age related differences in the developing brain
Genc, S., Malpas, C. B., Holland, S. K., Beare, R., & Silk, T. J. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.01.023 · Cited by 119
Response inhibition is associated with white matter microstructure in children.
Madsen, K. S., Baaré, W. F. C., Vestergaard, M., Skimminge, A., Ejersbo, L. R., Ramsøy, T. Z., Gerlach, C., Åkeson, P., Paulson, O. B., & Jernigan, T. L. (2010) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2009.11.001 · Cited by 104
Layer-specific diffusion weighted imaging in human primary visual cortex in vitro
Kleinnijenhuis, M., Zerbi, V., Küsters, B., Slump, C. H., Barth, M., & van Cappellen van Walsum, A.-M. (2013) · Cortex · doi:10.1016/j.cortex.2012.11.015 · Cited by 71
“Another useful improvement in this respect was proposed by Dell’Acqua et al. (2010) who account for the isotropic partial volume component in spherical deconvolution approaches.”
BackgroundJurcoane, A., Keil, F., Szelenyi, A., Pfeilschifter, W., Singer, O. C., & Hattingen, E. (2014) · Neuroradiology · doi:10.1007/s00234-013-1289-8 · Cited by 45
ADHD severity is associated with white matter microstructure in the subgenual cingulum
Cooper, M., Thapar, A., & Jones, D. K. (2015) · NeuroImage: Clinical · doi:10.1016/j.nicl.2015.02.012 · Cited by 33
“Received 12 November 2014 Received in revised form 20 February 2015 Accepted 22 February 2015 Available online 26 February 2015”
BackgroundMethodWinston, G. P., Mancini, L., Stretton, J., Ashmore, J., Symms, M. R., Duncan, J. S., & Yousry, T. A. (2011) · Epilepsy Research · doi:10.1016/j.eplepsyres.2011.07.019 · Cited by 32
Self-citation
Metadata
- Authors
- Cook, P. A., Symms, M., Boulby, P. A., & Alexander, D. C.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2007-04-24
- Volume
- 25
- Issue
- 5
- Pages
- 1051-1058
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2150632270
- Cited by
- 131
- References
- 3
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.