The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
Open accessAbstract
Purpose: To evaluate the validity of different approaches to determine the signal‐to‐noise ratio (SNR) in MRI experiments with multi‐element surface coils, parallel imaging, and different reconstruction filters. Materials and Methods: Four different approaches of SNR calculation were compared in phantom measurements and in vivo based on: 1) the pixel‐by‐pixel standard deviation (SD) in multiple repeated acquisitions; 2) the signal statistics in a difference image; and 3) and 4) the statistics in two separate regions of a single image employing either the mean value or the SD of background noise. Different receiver coil systems (with one and eight channels), acquisitions with and without parallel imaging, and five different reconstruction filters were compared. Results: Averaged over all phantom measurements, the deviations from the reference value provided by the multiple‐acquisitions method are 2.7% (SD 1.6%) for the difference method, 37.7% (25.9%) for the evaluation of the mean value of background noise, and 34.0% (38.1%) for the evaluation of the SD of background noise. Conclusion: The conventionally determined SNR based on separate signal and noise regions in a single image will in general not agree with the true SNR measured in images after the application of certain reconstruction filters, multichannel reconstruction, or parallel imaging. J. Magn. Reson. Imaging 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Mathematical Analysis of Random Noise
Rice, S. O. (1944) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1944.tb00874.x · Cited by 5,480
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Measurement of signal intensities in the presence of noise in MR images
Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595711 · Cited by 1,017
Image reconstruction in SNR units: A general method for SNR measurement†
Kellman, P., & McVeigh, E. R. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20713 · Cited by 535
Signal‐to‐noise measurements in magnitude images from NMR phased arrays
Constantinides, C. D., Atalar, E., & McVeigh, E. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380524 · Cited by 510
Measuring signal-to-noise ratios in MR imaging.
Kaufman, L., Kramer, D. M., Crooks, L. E., & Ortendahl, D. A. (1989) · Radiology · doi:10.1148/radiology.173.1.2781018 · Cited by 360
Reeder, S. B., Wintersperger, B. J., Dietrich, O., Lanz, T., Greiser, A., Reiser, M. F., Glazer, G. M., & Schoenberg, S. O. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20636 · Cited by 302
Self-citationA comparison of two methods for measuring the signal to noise ratio on MR images
Firbank, M. J., Coulthard, A., Harrison, R. M., & Williams, E. D. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/12/403 · Cited by 256
Edelstein, W. A., Bottomley, P. A., & Pfeifer, L. M. (1984) · Medical Physics · doi:10.1118/1.595484 · Cited by 230
Noise and filtration in magnetic resonance imaging
McVeigh, E. R., Henkelman, R. M., & Bronskill, M. J. (1985) · Medical Physics · doi:10.1118/1.595679 · Cited by 222
Field‐of‐view limitations in parallel imaging
Griswold, M. A., Kannengießer, S., Heidemann, R. M., et al. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20249 · Cited by 146
SNR-optimality of sum-of-squares reconstruction for phased-array magnetic resonance imaging
Larsson, E. G., Erdoğmuş, D., Yan, R., et al. (2003) · Journal of Magnetic Resonance · doi:10.1016/s1090-7807(03)00132-0 · Cited by 115
Signal-to-noise ratio and signal-to-noise efficiency in SMASH imaging
Sodickson, D. K., Griswold, M. A., Jakob, P. M., Edelman, R. R., & Manning, W. J. (1999) · Magnetic Resonance in Medicine · Cited by 99
Signal-to-noise measures for magnetic resonance imagers
Murphy, B. W., Carson, P. L., Ellis, J. H., Zhang, Y. T., Hyde, R. J., & Chenevert, T. L. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90076-p · Cited by 86
Scalable multichannel MRI data acquisition system
Bodurka, J., Ledden, P. J., van Gelderen, P., Chu, R., de Zwart, J. A., Morris, D., & Duyn, J. H. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10693 · Cited by 71
Contrast‐enhanced peripheral MR angiography using SENSE in multiple stations: Feasibility study
de Vries, M., Nijenhuis, R. J., Hoogeveen, R. M., de Haan, M. W., van Engelshoven, J. M. A., & Leiner, T. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20240 · Cited by 61
Cited by
Jeurissen, B., Leemans, A., Tournier, J., Jones, D. K., & Sijbers, J. (2013) · Human Brain Mapping · doi:10.1002/hbm.22099 · Cited by 1,088
MRIQC: Advancing the automatic prediction of image quality in MRI from unseen sites
Esteban, O., Birman, D., Schaer, M., Koyejo, O. O., Poldrack, R. A., & Gorgolewski, K. J. (2017) · PLOS ONE · doi:10.1371/journal.pone.0184661 · Cited by 920
Diffusion MRI noise mapping using random matrix theory
Veraart, J., Fieremans, E., & Novikov, D. S. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26059 · Cited by 773
Robson, P. M., Grant, A. K., Madhuranthakam, A. J., Lattanzi, R., Sodickson, D. K., & McKenzie, C. A. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21728 · Cited by 438
Diffusion Tensor MR Imaging and Fiber Tractography: Technical Considerations
Mukherjee, P., Chung, S. W., Berman, J. I., Hess, C. P., & Henry, R. G. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1052 · Cited by 390
Metadata
- Authors
- Dietrich, O., Raya, J. G., Reeder, S. B., Reiser, M. F., & Schoenberg, S. O.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2007-07-10
- Volume
- 26
- Issue
- 2
- Pages
- 375-385
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2131752914
- Cited by
- 992
- References
- 23
- FWCI
- 18.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.