Reproducibility of 3.0 Tesla magnetic resonance spectroscopy for measuring hepatic fat content
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Purpose: To investigate reproducibility of proton magnetic resonance spectroscopy (1 H‐MRS) to measure hepatic triglyceride content (HTGC). Materials and Methods: In 24 subjects, HTGC was evaluated using 1 H‐MRS at 3.0 Tesla. We studied “between‐weeks” reproducibility and reproducibility of 1 H‐MRS in subjects with fatty liver. We also studied within liver variability and within day reproducibility. Reproducibility was assessed by coefficient of variation (CV), repeatability coefficient (RC), and intraclass correlation coefficient (ICC). Results: The CV of between weeks reproducibility was 9.5%, with a RC of 1.3% HTGC (ICC 0.998). The CV in fatty livers was 4.1%, with a RC of 1.3% HTGC (ICC 0.997). Within day CV was 4.5%, with a RC of 0.4% HTGC (ICC 0.999). CV for within liver variability was 14.5%. Conclusion: Reproducibility of 1 H‐MRS to measure HTGC for “between‐weeks” measurements and in fatty livers is high, which is important for follow‐up studies. Within liver variability displays a larger variation, meaning that liver fat is not equally distributed and during consecutive measurements the same voxel position should be used. J. Magn. Reson. Imaging 2009;30:444–448. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A placebo-controlled trial of pioglitazone in subjects with nonalcoholic steatohepatitis
Belfort, R., Harrison, S. A., Brown, K., Darland, C., Finch, J., Hardies, J., Balas, B., Gastaldelli, A., Tio, F., Pulcini, J., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa060326 · Cited by 1,827 · cited 1×
“Noninvasive (1)H-MRS is also suitable to determine HTGC and follow up patients in clinical trails (17).”
BackgroundMeasurement of intracellular triglyceride stores by H spectroscopy: validation in vivo
Szczepaniak, L. S., Babcock, E. E., Schick, F., Dobbins, R. L., Garg, A., Burns, D. K., McGarry, J. D., & Stein, D. T. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.276.5.e977 · Cited by 688
Quantification of liver fat using magnetic resonance spectroscopy
Thomsen, C., Becker, U., Winkler, K., Christoffersen, P., Jensen, M., & Henriksen, O. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92543-7 · Cited by 332
Johnson, N. A., Walton, D. W., Sachinwalla, T., Thompson, C. H., Smith, K., Ruell, P. A., Stannard, S. R., & George, J. (2008) · Hepatology · doi:10.1002/hep.22220 · Cited by 164 · cited 3×
“Johnson et al (21) found a CV of 3.6% in five subjects, and Thomas et al (20) a CV of 7% in 34 subjects.”
BackgroundInfluentialMachann, J., Thamer, C., Schnoedt, B., Stefan, N., Haring, H., Claussen, C. D., Fritsche, A., & Schick, F. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20825 · Cited by 162 · cited 3×
“Another study by Machann et al (28) showed variations up to 10% in five healthy volunteers.”
BackgroundInfluential
Cited by
Bohte, A. E., van Werven, J. R., Bipat, S., & Stoker, J. (2011) · European Radiology · doi:10.1007/s00330-010-1905-5 · Cited by 543
Self-citationThoma, C., Day, C. P., & Trenell, M. I. (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2011.06.010 · Cited by 523
van Werven, J. R., Marsman, H. A., Nederveen, A. J., Smits, N. J., ten Kate, F. J., van Gulik, T. M., & Stoker, J. (2010) · Radiology · doi:10.1148/radiol.10091790 · Cited by 329
Self-citationEffect of green-Mediterranean diet on intrahepatic fat: the DIRECT PLUS randomised controlled trial
Yaskolka Meir, A., Rinott, E., Tsaban, G., Zelicha, H., Kaplan, A., Rosen, P., Shelef, I., Youngster, I., Shalev, A., Blüher, M., et al. (2021) · Gut · doi:10.1136/gutjnl-2020-323106 · Cited by 287
Elucidating Metabolic Maturation in the Healthy Fetal Brain Using1H-MR Spectroscopy
Evangelou, I. E., du Plessis, A. J., Vezina, G., Noeske, R., & Limperopoulos, C. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4512 · Cited by 37
Metadata
- Authors
- van Werven, J. R., Hoogduin, J. M., Nederveen, A. J., van Vliet, A. A., Wajs, E., Vandenberk, P., Stroes, E. S. G., & Stoker, J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2009-07-23
- Volume
- 30
- Issue
- 2
- Pages
- 444-448
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2039849925
- Cited by
- 79
- References
- 6
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of 3.0 Tesla magnetic resonance spectroscopy for measuring hepatic fat content. https://app.cochat.ai/papers/10.1002/jmri.21837
- The paper
- van Werven, J. R., Hoogduin, J. M., Nederveen, A. J., van Vliet, A. A., Wajs, E., Vandenberk, P., Stroes, E. S. G., & Stoker, J. (2009). Reproducibility of 3.0 Tesla magnetic resonance spectroscopy for measuring hepatic fat content. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21837
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.