The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Susceptibility mapping as a means to visualize veins and quantify oxygen saturation
Open accessAbstract
Purpose: To create an orientation‐independent, 3D reconstruction of the veins in the brain using susceptibility mapping. Materials and Methods: High‐resolution, high‐pass filtered phase images usually used for susceptibility weighted imaging (SWI) were used as a source for local magnetic field behavior. These images were subsequently postprocessed using an inverse procedure to generate susceptibility maps of the veins. Regularization and interpolation of the data in k‐space of the phase images were used to reduce reconstruction artifacts. To understand the effects of artifacts, and to fine‐tune the methodology, simulations of blood vessels were performed with and without noise. Results: With sufficient resolution, major veins in the brain could be visualized with this approach. The usual geometry‐dependent phase dipole effects are removed by this processing, leaving basically images of the veins. Different sized vessels show a different level of contrast depending on their partial volume effects. Vessels that are 8 mm or 16 mm in size show quantitative values expected for normal oxygen saturation levels. Smaller vessels show smaller values due to errors in the methodology and due to partial volume effects. Larger vessels show a bias toward a reduced susceptibility approaching 90% of the expected value. Limitations of the method and artifacts related to different sources of errors are demonstrated. Conclusion: Susceptibility maps can successfully create venograms of the brain with varying levels of contrast‐to‐noise depending on the size of the vessel. Partial volume effects render this approach more useful as an imaging tool or a visualization tool, although certain larger vessels have measured susceptibilities close to expected values associated with normal blood oxygen saturation levels. J. Magn. Reson. Imaging 2010;32:663–676. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
Self-citationSmall vessels in the human brain: MR venography with deoxyhemoglobin as an intrinsic contrast agent.
Reichenbach, J. R., Venkatesan, R., Schillinger, D. J., Kido, D. K., & Haacke, E. M. (1997) · Radiology · doi:10.1148/radiology.204.1.9205259 · Cited by 605
Self-citationLiu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Marques, J. P., & Bowtell, R. (2005) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.20034 · Cited by 434
Salomir, R., de Senneville, B. D., & Moonen, C. T. (2003) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.10083 · Cited by 389
NMR multiple echoes observed in solidHe3
Deville, G., Bernier, M., & Delrieux, J. M. (1979) · Physical Review B · doi:10.1103/physrevb.19.5666 · Cited by 324
Susceptibility contrast in high field MRI of human brain as a function of tissue iron content
Yao, B., Li, T.-Q., Gelderen, P. V., Shmueli, K., de Zwart, J. A., & Duyn, J. H. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.029 · Cited by 282
Identification of calcification with MRI using susceptibility‐weighted imaging: A case study
Wu, Z., Mittal, S., Kish, K., Yu, Y., Hu, J., & Haacke, E. M. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21617 · Cited by 260
Self-citationHaacke, E. M., Lai, S., Reichenbach, J. R., Kuppusamy, K., Hoogenraad, F. G. C., Takeichi, H., & Lin, W. (1997) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1997)5:5<341::aid-hbm2>3.0.co;2-3 · Cited by 224
Self-citationKressler, B., de Rochefort, L., Liu, T., Spincemaille, P., Jiang, Q., & Wang, Y. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2023787 · Cited by 220
Koch, K. M., Papademetris, X., Rothman, D. L., & de Graaf, R. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/24/007 · Cited by 126
Susceptibility Weighted Imaging: Clinical Angiographic Applications
Barnes, S. R. S., & Haacke, E. (2009) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2008.12.002 · Cited by 114
Self-citationUsing magnetic field simulation to study susceptibility-related phase contrast in gradient echo MRI
Schäfer, A., Wharton, S., Gowland, P. A., & Bowtell, R. W. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.05.093 · Cited by 113
Xu, Y., & Haacke, E. M. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.10.030 · Cited by 98
Self-citationCheng, Y. N., Neelavalli, J., & Haacke, E. M. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/005 · Cited by 79
Self-citationNeelavalli, J., Cheng, Y. N., Jiang, J., et al. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21693 · Cited by 76
Self-citationLangham, M. C., Magland, J. F., Epstein, C. L., Floyd, T. F., & Wehrli, F. W. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21981 · Cited by 54
Sedlacik, J., Helm, K., Rauscher, A., Stadler, J., Mentzel, H., & Reichenbach, J. R. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.11.046 · Cited by 47
Identification of breast calcification using magnetic resonance imaging
Fatemi‐Ardekani, A., Boylan, C., & Noseworthy, M. D. (2009) · Medical Physics · doi:10.1118/1.3250860 · Cited by 45
Pandian, D. S. J., Ciulla, C., Haacke, E. M., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21487 · Cited by 37
Self-citationHigh Resolution EPI fMRI Using A Head Gradient Coil Insert
Haacke, E. M., Kuppusamy, K., Thompson, M., Venkatesan, R., Çelik, A., Lin, W., Hoogenraad, F. G. C., & Reichenbach, J. R. (1998) · NeuroImage · doi:10.1016/s1053-8119(18)31380-6 · Cited by 1
Self-citation
Cited by
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Self-citationLiu, J., Liu, T., de Rochefort, L., Ledoux, J., Khalidov, I., Chen, W., Tsiouris, A. J., Wisnieff, C., Spincemaille, P., Prince, M. R., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.082 · Cited by 498
Deistung, A., Schäfer, A., Schweser, F., Biedermann, U., Turner, R., & Reichenbach, J. R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.055 · Cited by 442
Liu, T., Wisnieff, C., Lou, M., Chen, W., Spincemaille, P., & Wang, Y. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24272 · Cited by 360
Metadata
- Authors
- Haacke, E. M., Tang, J., Neelavalli, J., & Cheng, Y. C. N.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2010-08-27
- Volume
- 32
- Issue
- 3
- Pages
- 663-676
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2115900472
- Cited by
- 306
- References
- 21
- FWCI
- 13.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.