Purpose: To evaluate 7T MRI in the assessment of cerebrovascular alterations as seen in vascular dementia by means of detection of cerebral microbleeds (CMB) and depiction of white matter lesions (WML). 7T imaging was evaluated with respect to 1.5T. Materials and Methods: Ten healthy volunteers and 10 patients with CMBs and/or WMLs were examined at 1.5T and 7T using gradient‐echo (T2*, SWI) and turbo‐spin‐echo sequences (FLAIR). Comparisons of image quality, CMB and WML detection rates between sequences and field strengths were performed. Results: Using high‐resolution SWI at 7T 129 CMBs were detected compared to 75 at 1.5T using clinical SWI. With T2* at 7T 101 CMBs could be detected (33 CMBs at 1.5T). Lesion sizes were significantly larger for higher field strength. FLAIR images at 7T highlighted WMLs known from 1.5T with comparable extent. Gray and white matter contrast in FLAIR was slightly better at 1.5T, whereas image resolution and contrast of the WMLs to surrounding tissue was higher at 7T. Conclusion: By means of higher sensitivity for CMBs, 7T (SWI, T2*) might have significant impact on the early detection, diagnosis, and optimized antithrombotic therapy of cerebrovascular patients (eg, vascular dementia) in the future. Given the current state of technical development, 7T is approximately on par with 1.5T in the depiction of WMLs and their distribution, but holds the potential for future improvements. J. Magn. Reson. Imaging 2011;33:782–791. © 2011 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.22513

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 87

Metadata

Authors
Theysohn, J. M., Kraff, O., Maderwald, S., Barth, M., Ladd, S. C., Forsting, M., Ladd, M. E., & Gizewski, E. R.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2011-03-29
Volume
33
Issue
4
Pages
782-791
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2092456180
Cited by
87
References
8
FWCI
8.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.